Yuanyuan Gang

Yuanyuan Gang

Auto-generated profile, based on publicly available information

Yuanyuan Gang

Key Laboratory of Fluid and Power Machinery, Ministry of Education, Xihua University 2 , Chengdu, Sichuan 610039

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 May 2025 in Energy Science & Engineering
Verified
Journal Article
Open access
ZZZiyao Zhou
Ziyao Zhou
PXPinyu Xiang
Pinyu Xiang
KXKang Xu
Kang Xu
JLJitao Liu
Jitao Liu
YGYuanyuan Gang
Yuanyuan Gang
XLXiaobing Liu
Xiaobing Liu
To examine the sand–water flow characteristics in the distributor of the Francis‐99 hydraulic turbine, numerical simulations were conducted using the Mixture multiphase flow model, focusing on the impact of varying sand particle sizes. The findings indicate that near‐wall velocities of sand and water in the fixed and guide vanes of the Francis‐99 hydraulic turbine range from 1.5 to 3.4 m/s and from 2.1 to 11.2 m/s, respectively, with the highest values observed at the tail section. The trajectories of smaller sand particles closely followed the water flow, whereas for particle sizes of around 0.3 mm, acceleration and deceleration processes showed a noticeable lag due to inertia, leading to significant velocity fluctuations compared to smaller particles. The sediment concentration on the front side of the stay and guide vanes initially increased and then decreased along the flow direction, whereas on the back side, a gradual reduction was observed, with the peak sediment concentration occurring at the head. As the sand particle size increased, the uniformity of the sediment concentration distribution on the guide vane surface decreased. When the average sediment concentration (volume fraction) in the flow field was 0.00095, the maximum concentration on the front side of the guide vane reached 0.0025, and the region of high concentration expanded, whereas the back side showed an opposite trend. The results further demonstrate that the arrangement of fixed and guide vanes influences the sediment concentration distribution in the sand–water flow within the hydraulic guide mechanism of the Francis‐99 hydraulic turbine, leading to inconsistencies in sediment distribution patterns on adjacent guide vane surfaces.

1 August 2025 in Physics of Fluids
Verified
Journal Article
Closed access
JLJitao Liu
Jitao Liu
XLXiaobing Liu
Xiaobing Liu
YGYuanyuan Gang
Yuanyuan Gang
BYBing Yao
Bing Yao
BXBo Xie
Bo Xie
XZXin Zhang
Xin Zhang
Sediment erosion presents a significant challenge in the development of high-head Pelton turbines operating in sandy rivers. This study investigates the hydrological sediment conditions of a large Pelton turbine in Tibet, China, utilizing a model turbine derived from preliminary design data (single unit > 500 MW class). The gas–liquid–solid three-phase transient flow characteristics within the model turbine are analyzed. The study calculated three working conditions with different sediment particle sizes and concentrations, analyzed the bucket erosion conditions, and conducted erosion tests on the model turbine under these three conditions. By integrating experimental data with numerical simulations, a mathematical model for sediment erosion in the model turbine bucket of this power station is developed. This model accurately predicts erosion in the actual Pelton turbine of the research power station and other similar stations. The findings offer a theoretical foundation and technical support for forecasting erosion in large-scale Pelton turbine buckets at this facility.

1 March 2025 in Physics of Fluids
Verified
Journal Article
Closed access
ZZZiyao Zhou
Ziyao Zhou
KXKang Xu
Kang Xu
YGYuanyuan Gang
Yuanyuan Gang
WXWenping Xiang
Wenping Xiang
ZZZebin Zhang
Zebin Zhang
XLXiaobing Liu
Xiaobing Liu
This study employed a design method for a single-channel sediment wear test device based on numerical simulation and the principle of similarity to investigate the characteristics of solid–liquid two-phase flow and the sediment wear mechanism of the Francis-99 turbine under sand-containing conditions. The design of the test device and the sediment wear tests for the diversion components of the Francis-99 turbine were conducted, and the similarity of the flow field was validated. The findings indicate that under the design conditions of the single-channel sediment wear test device and the prototype, the surface sediment particle velocity range for the stay vane is 1.4–1.8 m/s, while that for the guide vane is 1.1–6.2 m/s. The sediment particle velocity difference near the wall is about 0.02 m/s, and the sediment distribution pattern is relatively similar. The difference in the impact angle of sediment particles at the heads of the stay vane and guide vane is about 0.1°. The wear rate on the stay vane surface ranges from 0.1 to 0.4 μm/h, and on the active guide vane surface, it ranges from 0.1 to 0.55 μm/h, with the maximum wear rate occurring near the tail area. The single-channel sediment wear test device described in this paper effectively reveals the wear mechanism of hydraulic turbine diversion components and demonstrates high feasibility.