Xiaoxia Fang

Xiaoxia Fang

Auto-generated profile, based on publicly available information

Xiaoxia Fang

School of Biomedical Engineering Med‐X Research Institute Shanghai Jiao Tong University Shanghai China

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 May 2022 in Biosensors and Bioelectronics
Verified
Journal Article
Closed access
XYXiaoyu Yue
Xiaoyu Yue
XFXiaoxia Fang
Xiaoxia Fang
TSTong Sun
Tong Sun
JYJingwei Yi
Jingwei Yi
XKXiaojun Kuang
Xiaojun Kuang
HXHong Xu
Hong Xu

29 January 2018 in Scientific Reports
Verified
Journal Article
Open access
PDF file
JPJian-Zhang Pan
Jian-Zhang Pan
PFPan Fang
Pan Fang
XFXiao-Xia Fang
Xiao-Xia Fang
THTing-Ting Hu
Ting-Ting Hu
JFJin Fang
Jin Fang
QFQun Fang
Qun Fang
In this work, we developed a miniaturized palmtop high-speed capillary electrophoresis (CE) system integrating whole modules, including picoliter-scale sample injection, short capillary-based fast CE, high-voltage power supply, orthogonal laser induced fluorescence (LIF) detection, battery, system control, on-line data acquisition, processing, storage, and display modules. A strategy of minimalist miniaturization combining minimal system design and low-cost system construction was adopted to achieve the instrument miniaturization with extremely low cost, which is differing from the current microfabrication strategy used in most reported miniaturized CE systems. With such a strategy, the total size of the bioanalyzer was minimized to 90 × 75 × 77 mm (length × width × height) and the instrument cost was reduced to ca. $500, which demonstrated the smallest and lowest-cost CE instrument with LIF detection in so far reported systems. The present bioanalyzer also exhibited comparable analytical performances to previously-reported high-speed CE systems. A limit of detection of 1.02 nM sodium fluorescein was obtained. Fast separations were achieved for multiple types of samples as amino acids, amino acid enantiomers, DNA fragments, and proteins with high efficiency. We applied this instrument in colorectal cancer diagnosis for detecting KRAS mutation status by polymerase chain reaction-restriction fragment length polymorphism (PCR-RFLP) method.

1 April 2021 in Acta Biomaterialia
Verified
Journal Article
Closed access
XFXiaoxia Fang
Xiaoxia Fang
CCCang Chen
Cang Chen
BLBing Liu
Bing Liu
ZMZhijie Ma
Zhijie Ma
FHFenglin Hu
Fenglin Hu
HXHong Xu
Hong Xu

1 April 2016 in Talanta
Verified
Journal Article
Closed access
XFXiao-Xia Fang
Xiao-Xia Fang
HLHan-Yang Li
Han-Yang Li
PFPan Fang
Pan Fang
JPJian-Zhang Pan
Jian-Zhang Pan
QFQun Fang
Qun Fang

16 March 2024 in Mechanobiology in Medicine
Verified
Journal Article
Open access
XFXiaoxia Fang
Xiaoxia Fang
YYYiwen Yang
Yiwen Yang
HWHeni Wang
Heni Wang
HXHong Xu
Hong Xu
Multiplex ultrasensitive detection of low abundance proteins remains a significant challenge in clinical applications, necessitating the development of innovative solutions. The integration of bead-based microfluidic chip platforms with their efficient target capture and separation capabilities, along with the advantages of miniaturization and low reagent consumption, holds great promise for building an integrated point-of-care testing (POCT) system that enables seamless sample input-result output. This review presents a comprehensive overview of recent advancements in bead-based microfluidic platforms for multiplex and ultrasensitive immunoassays, along with their potential applications in clinical diagnosis and treatment, which is organized into four sections: encoding techniques, the role of microfluidic platforms, applications, and future prospects.

4 July 2016 in Electrophoresis
Verified
Journal Article
Closed access
PDF file
XFXiao‐Xia Fang
Xiao‐Xia Fang
PFPan Fang
Pan Fang
JPJian‐Zhang Pan
Jian‐Zhang Pan
QFQun Fang
Qun Fang