Steffen Greilich

Steffen Greilich

Auto-generated profile, based on publicly available information

Steffen Greilich

Division of Medical Physics in Radiation Oncology, German Cancer Research Center (DKFZ), Heidelberg, Germany

Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 December 2013 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
PDF file
NHNora Hünemohr
Nora Hünemohr
BKBernhard Krauss
Bernhard Krauss
CTChristoph Tremmel
Christoph Tremmel
BABenjamin Ackermann
Benjamin Ackermann
OJOliver Jäkel
Oliver Jäkel
SGSteffen Greilich
Steffen Greilich
We present an experimental verification of stopping-power-ratio (SPR) prediction from dual energy CT (DECT) with potential use for dose planning in proton and ion therapy. The approach is based on DECT images converted to electron density relative to water ϱe/ϱe, w and effective atomic number Zeff. To establish a parameterization of the I-value by Zeff, 71 tabulated tissue compositions were used. For the experimental assessment of the method we scanned 20 materials (tissue surrogates, polymers, aluminum, titanium) at 80/140Sn kVp and 100/140Sn kVp (Sn: additional tin filtration) and computed the ϱe/ϱe, w and Zeff with a purely image based algorithm. Thereby, we found that ϱe/ϱe, w (Zeff) could be determined with an accuracy of 0.4% (1.7%) for the tissue surrogates with known elemental compositions. SPRs were predicted from DECT images for all 20 materials using the presented approach and were compared to measured water-equivalent path lengths (closely related to SPR). For the tissue surrogates the presented DECT approach was found to predict the experimental values within 0.6%, for aluminum and titanium within an accuracy of 1.7% and 9.4% (from 16-bit reconstructed DECT images).

23 May 2014 in Medical Physics
Verified
Journal Article
Closed access
NHNora Hünemohr
Nora Hünemohr
HPHarald Paganetti
Harald Paganetti
SGSteffen Greilich
Steffen Greilich
OJOliver Jäkel
Oliver Jäkel
Joao SecoJoao Seco
Joao Seco

3 February 2009 in Medical Physics
Verified
Journal Article
Closed access
CAClaus E. Andersen
Claus E. Andersen
SNSøren Kynde Nielsen
Søren Kynde Nielsen
SGSteffen Greilich
Steffen Greilich
JHJakob Helt‐Hansen
Jakob Helt‐Hansen
JLJacob Christian Lindegaard
Jacob Christian Lindegaard
KTKari Tanderup
Kari Tanderup

1 August 2017 in Physics in Medicine & Biology
Verified
Journal Article
Open access
PDF file
CSClaudia Katharina Spindeldreier
Claudia Katharina Spindeldreier
OSOliver Schrenk
Oliver Schrenk
ABAnna Bakenecker
Anna Bakenecker
IKIwan Kawrakow
Iwan Kawrakow
LBLucas Norberto Burigo
Lucas Norberto Burigo
APAsja Pfaffenberger
Asja Pfaffenberger
The aim of this work was to determine magnetic field correction factors that are needed for dosimetry in hybrid devices for MR-guided radiotherapy for Farmer-type ionization chambers for different magnetic field strengths and field orientations. The response of six custom-built Farmer-type chambers irradiated at a 6 MV linac was measured in a water tank positioned in a magnet with magnetic field strengths between 0.0 T and 1.1 T. Chamber axis, beam and magnetic field were perpendicular to each other and both magnetic field directions were investigated. EGSnrc Monte Carlo simulations were compared to the measurements and simulations with different field orientations were performed. For all geometries, magnetic field correction factors, [Formula: see text], and perturbation factors were calculated. A maximum increase of 8.8% in chamber response was measured for the magnetic field perpendicular to chamber and beam axis. The measured chamber response could be reproduced by adjusting the dead volume layer near the chamber stem in the Monte Carlo simulations. For the magnetic field parallel to the chamber axis or parallel to the beam, the simulated response increased by 1.1% at maximum for field strengths up to 1.1 T. A complex dependence of the response was found on chamber radius, magnetic field strength and orientation of beam, chamber axis and magnetic field direction. Especially for magnetic fields perpendicular to beam and chamber axis, the exact sensitive volume has to be considered in the simulations. To minimize magnetic field correction factors and the influence of dead volumes on the response of Farmer chambers, a measurement set-up with the magnetic field parallel to the chamber axis or parallel to the beam is recommended for dosimetry.

1 August 2005 in Archaeometry
Verified
Journal Article
Closed access
PDF file
SGS. Greilich
S. Greilich
UGU. A. Glasmacher
U. A. Glasmacher
GWG. A. Wagner
G. A. Wagner

1 May 2010 in Journal of Luminescence
Verified
Journal Article
Closed access
VPV. Pagonis
V. Pagonis
CAC. Ankjærgaard
C. Ankjærgaard
AMA.S. Murray
A.S. Murray
Mayank JainMayank Jain
Mayank Jain
RCR. Chen
R. Chen
SGS. Greilich
S. Greilich