Gilbert Bergna-Diaz

Gilbert Bergna-Diaz

Auto-generated profile, based on publicly available information

Gilbert Bergna-Diaz

Department of Electric Power Engineering, Norwegian University of Science and Technology, Trondheim, Norway

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 January 2018 in IEEE Journal of Emerging and Selected Topics in Power Electronics
Verified
Journal Article
Open access
GBGilbert Bergna-Diaz
Gilbert Bergna-Diaz
JFJulian Freytes
Julian Freytes
XGXavier Guillaud
Xavier Guillaud
SDSalvatore D'ARco
Salvatore D'ARco
JSJon Are Suul
Jon Are Suul
This paper demonstrates that the sum and difference of the upper and lower arm voltages are suitable variables for deriving a generalized state-space model of an MMC which settles at a constant equilibrium in steady-state operation. The presented modelling approach allows for separating the multiple frequency components appearing within the MMC as a first step of the model derivation, to avoid variables containing multiple frequency components in steady-state. On this basis, it is shown that Park transformations at three different frequencies (+ω, -2ω and +3ω) can be applied for deriving a model formulation where all state-variables settle at constant values in steady-state, corresponding to an equilibrium point of the model. The resulting model is accurately capturing the internal current and voltage dynamics and the coupling between the different frequency components appearing in the variables of a three-phase MMC. Independently from the control system implementation, the derived equations are valid for accurate representation of the MMC in the applied dqz reference frames, and it can be linearized for utilization in eigenvalue-based analysis of small-signal dynamics. Furthermore, the model can be utilized for control system design by multi-variable methods requiring any stable equilibrium to be defined by a fixed operating point. Time-domain simulations in comparison to an established average model of the MMC, as well as results from a detailed simulation model of an MMC with 400 sub-modules per arm, are presented as verification of the validity and accuracy of the developed model.

17 July 2017 in IEEE Transactions on Power Electronics
Verified
Journal Article
Open access
GBGilbert Bergna-Diaz
Gilbert Bergna-Diaz
JSJon Are Suul
Jon Are Suul
SDSalvatore D'ARco
Salvatore D'ARco
The internal currents and voltages of modular multilevel converters (MMCs) contain multiple frequency components in steady-state operation and remain time-periodic even when transformed into a synchronously rotating reference frame. This prevents a straightforward state-space representation, where a constant equilibrium point is reached and all state variables converge to constant values under steady-state conditions. Such steady-state time-invariant (SSTI) representations are needed for linearization and eigenvalue-based analysis of small-signal stability. This paper presents an energy-based model of an MMC with a modulation strategy where the insertion indices are compensated for the oscillations in the sum arm voltage. The formulation of the model allows for deriving, by the application of Park transformations at three different frequencies, an SSTI representation that accurately captures the internal dynamics of the MMC. This model can be simplified to a reduced-order model that maintains accurate reproduction of the external behavior at the ac- and dc-sides while neglecting some of the internal dynamics. The validity and accuracy of these two SSTI MMC models are verified by time-domain simulations and their utilization for eigenvalue-based analysis of MMC dynamics is demonstrated by examples.

26 November 2021 in International Journal of Robust and Nonlinear Control
Verified
Journal Article
Open access
PDF file
DZDaniele Zonetti
Daniele Zonetti
GBGilbert Bergna‐Diaz
Gilbert Bergna‐Diaz
RORomeo Ortega
Romeo Ortega
NMNima Monshizadeh
Nima Monshizadeh
We present a full review of PID passivity‐based controllers (PBC) applied to power electronic converters, discussing limitations, unprecedented merits and potential improvements in terms of large‐signal stability, robustness and performance. We provide four main contributions. The nominal case is first considered and it is shown—under the assumption of perfect knowledge of the system parameters—that the PID‐PBC is able to guarantee global exponential stability of a desired operating point for any positive gains. Second, we analyze robustness of the controller to parameters uncertainty for a specific class of power converters, by establishing precise stability margins. Third, we propose a modification of the controller by introducing a leakage, in order to overcome some of the intrinsic performance and robustness limitations. Interestingly, such controller can be interpreted at steady‐state as a droop between the input and the passive output, similar to traditional primary controllers. Fourth, we robustify the design against saturation of the control input via an appropriate monotone transformation of the controller. The obtained results are thoroughly discussed and validated by simulations on two relevant power applications: a DC/DC boost converter and an HVDC grid‐connected voltage source converter.

21 December 2018 in IEEE Journal of Emerging and Selected Topics in Power Electronics
Verified
Journal Article
Closed access
GBGilbert Bergna-Diaz
Gilbert Bergna-Diaz
DZDaniele Zonetti
Daniele Zonetti
SSSantiago Sanchez
Santiago Sanchez
RORomeo Ortega
Romeo Ortega
Elisabetta TedeschiElisabetta Tedeschi
Elisabetta Tedeschi
In this work, a decentralized PI passivity-based controller (PI-PBC) is applied to Modular Multilevel Converters (MMCs) to ensure global stability of a multi-terminal HVDC system. For the derivation of the controller, an appropriate model with constant steady-state solutions is obtained via a multifrequency orthogonal coordinates transformation. The control design is next completed using passivity arguments and performance guarantees are established by a small-signal analysis. The obtained results are validated by means of detailed timedomain simulations both on a single-terminal and a four-terminal benchmark.

24 November 2020 in IEEE Transactions on Power Systems
Verified
Journal Article
Open access
EAErick Fernando Alves
Erick Fernando Alves
GBGilbert Bergna-Diaz
Gilbert Bergna-Diaz
Danilo BrandaoDanilo Brandao
Danilo Brandao
Elisabetta TedeschiElisabetta Tedeschi
Elisabetta Tedeschi
This paper analyses the frequency stability of ac grids in the presence of non-dispatchable generation and stochastic loads. Its main goal is to evaluate conditions in which the system is robust to large, persistent active power disturbances without recurring to time-domain simulations. Considering the ongoing energy transition to more renewable sources, defining robustness boundaries is a key topic for power system planning and operation. However, much of the research on long-term studies has not dealt with robust dynamic constraints, while short-term analyses usually depend on time-consuming simulations to evaluate nonlinearities. To bridge this gap, the authors derive an algebraic equation that provides sufficient conditions for robust frequency stability in ac power systems and a relationship among four key quantities: the maximum active power perturbation, the minimum system damping, the steady-state and the transient frequency limits. To achieve this goal, it uses a nonlinear average-model of the ac grid and Lyapunov's direct method extended by perturbation analysis requiring only limited knowledge of the system parameters. The algebraic calculations are validated using time-domain simulations of the IEEE 39-bus test system and results are compared to the traditional Swing Equation model.

24 December 2018 in IEEE Transactions on Power Systems
Verified
Journal Article
Closed access
SSSantiago Sanchez
Santiago Sanchez
Alejandro GarcesAlejandro Garces
Alejandro Garces
GBGilbert Bergna-Diaz
Gilbert Bergna-Diaz
Elisabetta TedeschiElisabetta Tedeschi
Elisabetta Tedeschi
This paper investigates the existence of an equilibrium point in multiterminal HVDC grids, assesses its uniqueness and defines conditions to ensure its stability. An offshore multiterminal HVDC system including two wind farms is selected as application test case. At first, a generalized dynamic model of the network is proposed, using multigraph theory. Such model captures the frequency dependence of transmission lines and cables, it is non-linear due to the constant power behavior of the converter terminals using droop regulation, and presents a suitable degree of simplifications of the modular multilevel converters, under given conditions, to allow system level studies over potentially large networks. Based on this model, the existence and uniqueness of the equilibrium point are demonstrated by returning the analysis to a load-flow problem and using the Banach fixed point theorem. Additionally, the stability of the equilibrium is analyzed by obtaining a Lyapunov function by the Krasovskii's theorem. Computational results obtained for the selected 4 terminal HVDC grid corroborate the requirement for the existence and stability of the equilibrium point.