29 June 2021 in Measurement Science and Technology
Industrial x-ray computed tomography (CT) represents an established measurement technique in the field of nondestructive testing and dimensional metrology. However, the measurement accuracy is sometimes limited by measurement artifacts that cannot be avoided using a standard circular scan trajectory. This problem can be addressed with the aid of flexible 3D trajectories, but up to date, the application of these is mainly restricted to special CT devices using robot arms. In this paper, we present results using a hexapod as an additional positioning system in a commercial industrial CT scanner. In addition to the 360∘rotation, task-specific tilting of the part during the scan is possible in this way. We used and adapted geometry calibration procedures based on a multi-sphere reference object to enable reconstruction with high accuracy. Using a demonstrator test fixture with high absorbing elements, we show that severe metal and truncation artifacts can be avoided for a region-of-interest scan. Furthermore, cone-beam artifacts, which are inherent to circular scan trajectories, can be reduced significantly. Using measurement objects that can be measured well with a circular trajectory, we found that applying a 3D trajectory leads to dimensional measurement deviations in the same range or even lower than those of a circular trajectory. This suggests that the pose repeatability of the hexapod is sufficient to perform complex scan paths without general loss of accuracy. The obtained results could be relevant for end users of conventional CT scanners, as upgrading existing devices is in principle possible. The presented investigations form the basis for the application of trajectory optimization algorithms.
28 October 2022 in Measurement Science and Technology
In industrial x-ray computed tomography (CT), the application of more complex scan paths in comparison to the typical circular trajectory ( rotation of the measurement object) can extend the potential of CT. One way to enable such 3D scan trajectories is to use a 6-degrees-of-freedom (DOF) object manipulator system. In our case, a hexapod is mounted on top of the rotary table of a commercial CT scanner. This allows for adaptive tilting of the measurement object during the scan. For high accuracy, the geometry calibration of such setups is typically done using the x-ray projections of a calibrated multi-sphere object. Contrary to this, here, we demonstrate a procedure that is based on only a single sphere and can therefore experimentally be implemented with low effort. Using the intrinsic geometry parameters of the CT device as prior information, the hexapod coordinate system with respect to the CT machine coordinate system is determined by means of a one-step optimization approach. The resulting parameters are used to calculate projection matrices that enable the volume reconstruction for 3D scan trajectories. The method is validated using simulated x-ray images and experimental investigations including dimensional measurements. For the used setup, geometric measurement results for 3D scan trajectories that are calibrated with the presented method show in sum increased errors compared to the circular scans. A limited pose accuracy of the manipulator system is discussed as a potential cause. The results nevertheless indicate that the presented method is generally feasible for dimensional CT measurements provided that the pose accuracy is sufficient. The calibration procedure can therefore be a low-cost and easier to implement alternative compared to trajectory calibration methods based on multi-sphere objects, but with a tendency towards lower measurement accuracy. The methodology can in principle be transferred to different setups with 6-DOF manipulator systems, e.g. C-arm CT devices with a robot arm.
1 March 2024 in e-Journal of Nondestructive Testing
U(University of Erlangen-Nürnberg (FAU)
University of Erlangen-Nürnberg (FAU)
DTDeggendorf Institute of Technology
Deggendorf Institute of Technology
+3
CT systems with high degrees of freedom such as robot-guided setups allow CT scanning with arbitrary 3D trajectories. However, many existing systems require an additional calibration scan to determine the exact source/detector poses of new trajectories. I....
15 January 2025 in Measurement Science and Technology
Industrial x-ray computed tomography (CT) systems with high geometric flexibility are increasingly utilized for large-scale measurement objects or challenging measurement tasks. To maintain high accuracy when deviating from the established circular scan trajectory, trajectory calibration methods using multi-sphere reference objects with known marker positions are commonly employed. These multi-sphere objects can either be scanned together with the measurement object (online trajectory calibration) or in a separate scan (offline trajectory calibration). While offline calibration increases machine time, it generally results in higher scan quality. However, a sufficient pose repeatability is necessary to ensure comparable or even superior accuracy to online calibration. In this contribution, we present a straightforward procedure to compare both types of trajectory calibration in a way that the differences of the results can directly be traced back to the influence of the pose repeatability. The multi-sphere reference object is not only used for trajectory calibration, but simultaneously as a measurement object for repeated measurements. The methodology is tested on both a twin robotic CT system and a conventional CT system that is additionally equipped with a hexapod manipulator for adaptive object tilting. Results showed, independent from the type of trajectory calibration, systematic measurement errors in the order of 10−5–10−4 of measured sphere distances and sphericity values below 50 . For sphere distances, random errors were increased by a factor of 5 due to the offline trajectory calibration, but were still low ( ) in comparison to systematic errors and the spread of different measurement features. Overall, both investigated systems demonstrated sufficient positioning repeatability for offline trajectory calibration. The method is in general also applicable to any other types of manipulator systems used for CT devices. It provides a workflow for the decision which type of trajectory calibration is preferable for a given CT system.
1 March 2019 in e-Journal of Nondestructive Testing
U(University of Erlangen-Nürnberg (FAU)
University of Erlangen-Nürnberg (FAU)
The Largest Portal of Nondestructive Testing (NDT) Open Access Archive, Conference Proceedings, Journal Articles, News, Products, Services. Professional Networking, Exhibition, Forums, Jobs
1 February 2020 in e-Journal of Nondestructive Testing
U(University of Erlangen-Nürnberg (FAU)
University of Erlangen-Nürnberg (FAU)
In the field of industrial Computed Tomography (CT), the orientation of the workpiece influences the local quality of the reconstructed volume data and therefore dimensional measurements. In the literature, different a priori criteria for an optimal orientation are proposed, which are purely based on the part and setup geometry. However, it is not evident to which extent they correlate with the measurement accuracy or how different quality parameters should be weighted, especially if a wider range of materials and therefore different artefact contributions should be covered. In this work, existing methods and criteria are compared and extended. In contrast to most existing investigations, different quality parameters are evaluated not only globally, but also restricted to relevant regions of interest (ROI). A straightforward derivation for an analytical determination of surface areas affected by cone-beam artefacts is presented. Results show that an ROI-based evaluation is important to find an optimal orientation for single measurands. The investigated quality parameter based on the prediction of surface areas which are affected by cone-beam artefacts was found to be applicable as exclusion criterion. This only holds true if the evaluation is restricted to relevant ROI surface areas, which should also be considered when evaluating the maximum X-ray penetration length as quality parameter. The correlation of the latter with resulting measurement deviations was found to depend on the measurement task.