Rui Guo

Rui Guo

Auto-generated profile, based on publicly available information

Rui Guo

Chinese Academy of Sciences, Shenyang Institute of Automation and the Institutes for Robotics and Intelligent Manufacturing, Shenyang, China

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 March 2025 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
GTGuangchao Tan
Guangchao Tan
JDJinsong Du
Jinsong Du
RGRui Guo
Rui Guo
WWWei Wang
Wei Wang
ZJZhaojie Ju
Zhaojie Ju
Robots equipped with 2D laser profile scanners are widely utilized in industrial manufacturing processes. The hand-eye calibration is a critical aspect of robot 3D measurement and significantly influences the accuracy of the measured point cloud. This paper introduces a robust hand-eye calibration method that employing a single planar artifact in three steps. Firstly, the normal vector of the calibration plane is determined by utilizing points gathered through translation motions. Secondly, the rotation part is determined by the fact that the regression line of a single scan taken on a planar surface is orthogonal to the normal vector of the calibration plane. The translation vector is ultimately determined by leveraging the property that the line connecting the centers of two scans is perpendicular to the plane’s normal vector. The objective function is formulated using the Principal Component Analysis (PCA) technique and the Kronecker product. We propose a dual-constraint rotation objective function to enhance the robustness of the method against measurement noise. A closed-form solution is derived by employing the least squares method. The proposed methodology can directly calculate the accurate hand-eye matrix and exhibits a favorable tolerance for measurement noise originating from the scanner and deviations in robot pose. The effectiveness of the proposed algorithm has been confirmed through validation using both simulated data and real-world experiments.

13 February 2026 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
GTGuangchao Tan
Guangchao Tan
WWWei Wang
Wei Wang
RGRui Guo
Rui Guo
XYXu Yang
Xu Yang
JDJinsong Du
Jinsong Du
ZJZhaojie Ju
Zhaojie Ju
The utilization of 3D robot measurement systems, which integrate 2D profile scanners with industrial robots, is prevalent in manufacturing industries. Nonetheless, the measurement precision of such devices is often compromised due to inaccuracies in the robot kinematic parameters and the handeye matrix. This paper presents a novel simultaneous calibration methodology that concurrently resolves the issues related to robot kinematic parameters and the hand-eye relationship through the application of radius constraint. By integrating the hand-eye matrix into the robotic kinematic chain, an integrated model of the robot measurement system is formulated. Combining the spherical equation with the integrated kinematic model, a radius error model is established. The Jacobian matrix associated with the radius error is approximated using Taylor expansion. An iterative approach is proposed to identify the values of system parameters, which include both joint twists and hand-eye twist. Simulation results validate the effectiveness of the proposed algorithm, demonstrating its robustness to measurement noise. In practical applications, the maximum radius error was reduced from 4.480 mm to 1.721 mm, representing an accuracy improvement of 61.58%. Additionally, the average radius error decreased from 2.680 mm to 0.092 mm, indicating a substantial accuracy enhancement of 95.56%.