Objectives: Condylar head fractures are common in facial trauma and can result in significantly impaired mandibular function. Open Reduction and internal fixation overall produce better functional outcomes than closed treatment. Multiple methods of fixation have been proposed, including the use of biodegradable magnesium-based cannulated bone screws. This study aims to investigate the long-term efficacy of this fixation method using three-dimensional radiographic imaging and clinical outcomes. Materials and methods: This retrospective cohort study of a single centre included patients who underwent surgical intervention for a condylar head fracture using a cannulated magnesium lag screw. Clinical parameters and three-dimensional radiographic scans were collected during follow-up, and virtual model analysis was conducted after segmentation. Results: Fifty-eight patients received an osteosynthesis with a magnesium alloy implant. The functional results of the final assessment were excellent. Significant changes in volume, surface area, and signs of condylar remodelling were observed during the healing process. Complication rates were low. No implant had to be removed. Conclusions: Cannulated compression screws using biodegradable magnesium-based alloys show good clinical results despite reduced condylar volume and surface area, as well as significant proof of three-dimensional incongruency of healing mandibular condyles. No patient complained of subjective problems connected to the resorption process, and no mechanical failure prior to fracture healing was recorded. Overall, this method verifies excellent long-term results. Clinical relevance: Surgical implants comprised of magnesium alloys provide adequate fixation of fractures of the condylar head with excellent clinical results without the need for a second intervention to remove the implant.
14 February 2025 in International Journal of Oral and Maxillofacial Surgery
The treatment of mandibular fractures affecting the condylar head (CHF) can be either closed or open. In the case of an open approach, the headless bone screw (HBS) is an option. This study was performed to investigate the efficacy of osteosynthesis with HBS using three-dimensional radiographic imaging and clinical evaluation over long-term follow-up. This was a single-centre retrospective study. Clinical parameters and three-dimensional radiographic scans were collected during follow-up, DICOM datasets were segmented, and model analysis was conducted. Forty-five patients who received a HBS and met the eligibility criteria were included. There were significant improvements in all clinical parameters (mouth opening, protrusion, laterotrusion; all P < 0.05) except for the laterotrusion of the unaffected side (P = 0.071). Mean volume and surface area changes (from postoperative (mean 1.9 days) to final follow-up (mean 1675 days)) were 127.2 mm3 and -22.4 mm2, respectively, and were not statistically significant (P = 0.18 and P = 0.51). There were radiographic signs of condylar remodelling. Nine HBS in nine patients required removal due to the screw penetrating the articular surface of the healing condylar head. This single-centre retrospective study found good functional outcomes using HBS for CHF, with a screw removal rate of 20%.
21 March 2024 in Journal of Cranio-Maxillofacial Surgery
Fractures of the mandibular condyle account for a significant proportion of mandibular fractures. The specific functional loads require particular specifications for the implant design used for open reduction and internal fixation of such fractures. The clinical and radiographic outcomes in patients treated using a single rhombic 3D condylar fracture plate for open reduction and internal fixation at a single institution, and who fulfilled the inclusion and exclusion criteria, are presented. The primary outcome variables were: occlusion, maximum interincisal distance and mandibular excursion at 1, 3, and 6 months postoperatively, and radiographic measurements for mandibular height and gonion angle. In total, 263 patients were included, of whom 173 (65.8%) were male and 90 (34.2%) female. The mean age was 40.4 ± 18.9 years. There was satisfactory occlusion in 98.9% of patients at the 6-month follow-up, and a significant improvement in all parameters for mandibular excursion (p < 0.001), with a reduced ramus height and an increase in the gonion angle on the fractured side. Excellent clinical and radiographic results were achieved using the rhombic-shaped implant, deeming it appropriate for the osteosynthesis of mandibular condyle fractures.
29 January 2025 in Journal of Cranio-Maxillofacial Surgery
Fractures involving the mandibular condyle are a significant subset of mandibular fractures, demanding specialized implant design considerations for effective surgical treatment. The core objective of this study was to assess the clinical and radiographic results in patients treated with a single rhombic-shaped implant according to the surgical approach used. This retrospective cohort investigation, spanning a ten-year recruitment window, included individuals with unilateral fractures who underwent surgical treatment with a rhombic-shaped implant. These patients were subject to follow-up examinations at one, three, and six months post-surgery, along with corresponding orthopantomograms and clinical assessments. Patients were allocated into four groups depending on the fracture pattern and level as well as the approach used for fracture treatment. The primary outcome variables under scrutiny encompassed parameters such as occlusion, maximum interincisal distance, mandibular excursion across different postoperative time points, and radiographic measurements of mandibular height and the gonion angle. A total of 236 patients, comprising 161 males and 75 females, with an average age of 40.2 ± 19.2 years, were included in the study. Satisfactory occlusion was exhibited in 99.6% of patients at the six-month follow-up. Furthermore, all parameters associated with mandibular excursion displayed significant enhancements (p < 0.01). These improvements were accompanied by a reduction in ramus height and increased gonion angle on the fractured side. The investigation of the clinical and radiographic results suggest a tendency of the choice of the approach depending on the fracture pattern, but no statistically significant recommendations could be identified.