Anupam K. Garg

Anupam K. Garg

Auto-generated profile, based on publicly available information

Anupam K. Garg

Wilmer Eye Institute, Johns Hopkins Hospital, Baltimore, Maryland

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2012 in Investigative Ophthalmology & Visual Science
Verified
Journal Article
Closed access
MPMark E. Pennesi
Mark E. Pennesi
KMKeith V. Michaels
Keith V. Michaels
SMSienna S. Magee
Sienna S. Magee
AMAnastasiya Maricle
Anastasiya Maricle
SDSean P. Davin
Sean P. Davin
PFPeter J. Francis
Peter J. Francis
We characterize the in vivo changes over time in the retinal structure of wild-type mice alongside two lines of mice deficient in the β-subunit of phosphodiesterase (rd1 and rd10 mice) using spectral domain optical coherence tomography (SD-OCT). SD-OCT images were obtained using the Bioptigen spectral domain ophthalmic imaging system (SDOIS). Wild-type C57BL/6J, rd1 and rd10 mice ranging in age from P14 to P206 were sedated with 1% isoflurane. Horizontal and vertical linear scans through the optic nerve, and annular scans around the optic nerve were obtained. SD-OCT imaging of wild-type mice demonstrated visibility of the inner segment/outer segment (IS/OS) junction, external limiting membrane (ELM), outer nuclear layer (ONL), and outer plexiform layer (OPL). At P14, most rd10 mice exhibited normal SD-OCT profiles, but some displayed changes in the IS/OS junction. At the same time point, rd1 mice had severe outer retinal degeneration. In rd10 mice, imaging revealed loss of the IS/OS junction by P18, hyperreflective changes in the ONL at P20, hyperreflective vitreous opacities, and shallow separation of the neural retina from the RPE. Retinal separations were not observed in rd1 mice. Segmentation analysis in wild-type mice demonstrated relatively little variability between animals, while in rd10 and rd1 mice there was a steady decline in outer retinal thickness. Histologic studies demonstrated correlation of retinal features with those seen on SD-OCT scans. Segmentation analysis provides a quantitative and reproducible method for measuring in vivo retinal changes in mice. SD-OCT provides a non-invasive method of following long-term retinal changes in mice in vivo. Although rd10 and rd1 mice have mutations in the same gene, they demonstrate significantly different features on SD-OCT.

28 June 2019 in Science
Verified
Journal Article
Closed access
PDF file
AGAnupam K. Garg
Anupam K. Garg
PLPeichao Li
Peichao Li
MRMohammad S. Rashid
Mohammad S. Rashid
ECEdward M. Callaway
Edward M. Callaway
Rethinking primary visual cortex function: Understanding how color is coded in the brain is central to vision research. The presently dominant model suggests that color and orientation are separately extracted in the primate primary visual cortex. These characteristics are thought to be represented by neurons located in different cortical columns that project separately to higher visual areas for further processing. Working with macaques, Garg et al. recorded from thousands of neurons using two-photon calcium imaging with single-neuron resolution. Nearly half of sampled hue-selective neurons responded more strongly to equiluminant colored stimuli than to full-contrast achromatic stimuli. A majority of strongly color-preferring neurons were also orientation selective. Processing of orientation and color is thus combined at the earliest stages of visual processing, which challenges existing models. Science , this issue p. 1275

1 September 2015 in Investigative Ophthalmology & Visual Science
Verified
Journal Article
Open access
PDF file
SFShu Feng
Shu Feng
MGMichael J. Gale
Michael J. Gale
JFJonathan D. Fay
Jonathan D. Fay
AFAmbar Faridi
Ambar Faridi
HTHope E. Titus
Hope E. Titus
MPMark E. Pennesi
Mark E. Pennesi
Purpose: To describe a standardized flood-illuminated adaptive optics (AO) imaging protocol suitable for the clinical setting and to assess sampling methods for measuring cone density. Methods: Cone density was calculated following three measurement protocols: 50 × 50-μm sampling window values every 0.5° along the horizontal and vertical meridians (fixed-interval method), the mean density of expanding 0.5°-wide arcuate areas in the nasal, temporal, superior, and inferior quadrants (arcuate mean method), and the peak cone density of a 50 × 50-μm sampling window within expanding arcuate areas near the meridian (peak density method). Repeated imaging was performed in nine subjects to determine intersession repeatability of cone density. Results: Cone density montages could be created for 67 of the 74 subjects. Image quality was determined to be adequate for automated cone counting for 35 (52%) of the 67 subjects. We found that cone density varied with different sampling methods and regions tested. In the nasal and temporal quadrants, peak density most closely resembled histological data, whereas the arcuate mean and fixed-interval methods tended to underestimate the density compared with histological data. However, in the inferior and superior quadrants, arcuate mean and fixed-interval methods most closely matched histological data, whereas the peak density method overestimated cone density compared with histological data. Intersession repeatability testing showed that repeatability was greatest when sampling by arcuate mean and lowest when sampling by fixed interval. Conclusions: We show that different methods of sampling can significantly affect cone density measurements. Therefore, care must be taken when interpreting cone density results, even in a normal population.

22 May 2014 in British Journal of Ophthalmology
Verified
Journal Article
Open access
PDF file
BLBenjamin S Liu
Benjamin S Liu
STSergey Tarima
Sergey Tarima
AVAlexis Visotcky
Alexis Visotcky
APAlex Pechauer
Alex Pechauer
RCRobert F Cooper
Robert F Cooper
JCJoseph Carroll
Joseph Carroll
Background Adaptive optics scanning light ophthalmoscopy (AOSLO) enables direct visualisation of the cone mosaic, with metrics such as cone density and cell spacing used to assess the integrity or health of the mosaic. Here we examined the interobserver and inter-instrument reliability of cone density measurements. Methods For the interobserver reliability study, 30 subjects with no vision-limiting pathology were imaged. Three image sequences were acquired at a single parafoveal location and aligned to ensure that the three images were from the same retinal location. Ten observers used a semiautomated algorithm to identify the cones in each image, and this was repeated three times for each image. To assess inter-instrument reliability, 20 subjects were imaged at eight parafoveal locations on one AOSLO, followed by the same set of locations on the second AOSLO. A single observer manually aligned the pairs of images and used the semiautomated algorithm to identify the cones in each image. Results Based on a factorial study design model and a variance components model, the interobserver study's largest contribution to variability was the subject (95.72%) while the observer's contribution was only 1.03%. For the inter-instrument study, an average cone density intraclass correlation coefficient (ICC) of between 0.931 and 0.975 was calculated. Conclusions With the AOSLOs used here, reliable cone density measurements can be obtained between observers and between instruments. Additional work is needed to determine how these results vary with differences in image quality.

14 November 2019 in Soft Computing
Verified
Journal Article
Closed access
PDF file
SDShaveta Dargan
Shaveta Dargan
MKMunish Kumar
Munish Kumar
AGAnupam Garg
Anupam Garg
KTKutub Thakur
Kutub Thakur

15 November 2019 in International Journal of Information Technology
Verified
Journal Article
Closed access
PDF file
AGAnupam Garg
Anupam Garg
MJManish Kumar Jindal
Manish Kumar Jindal
ASAmanpreet Singh
Amanpreet Singh