26 February 2021 in Technology audit and production reserves
The research object of this work is the parameters of organic light-emitting diodes, namely power and luminous flux. Determination of these parameters can be carried out using a photodiode and requires measuring the dark current of the sensor (photodiode), measuring the current of the photodiode when illuminated by the LED under investigation. And also take into account the relationship between the light flux received by the sensor and its output current, and take into account the spectral characteristics of the sensor. Calculate the investigated parameters of the LED based on the measurements. Carrying out these measurements requires laboratory instruments and workplace organization, and further calculations are routine work. It is possible to increase the measurement accuracy by improving the existing methods for measuring the required parameters, and it is possible to automate the process of measurements and calculations using a modern microprocessor radioelement base. Microcontrollers are widespread such radioelements. They have the necessary peripherals for independent operation and have sufficient computing power to implement the required measuring device. Its application makes it possible to automate the measurement process, carry out the necessary calculations, save correction constants, accumulate and process the obtained data, analyze these received data, exchange data with a computer, etc. So, the work is aimed at developing a methodology that will allow the simultaneous measurement of power and luminous flux of planar light sources. And also on the feasibility of this technique in the device and software with the ability to measure the power of the light source in an arbitrary band of the spectral visible range. Thus, it is possible to determine what power in watts a light source emits with the dynamics of supply currents in the optical bands, knowing the spectrum of this source without using glass filters. So, the result of applying the technique is to determine the power of light radiation (in watts) or the luminous flux (in lumens) of the emitter (light sources).
30 December 2025 in Security of Infocommunication Systems and Internet of Things
The article presents the results of a fibre Bragg grating (FBG) investigation. Two types of FBGs, uniform and tilted, were fabricated. They were inscribed in the cores of fibres using a UV excimer laser KrF Coherent Bragg Star M and the phase mask method. Photosensitive optical fibres GF1 were chosen for FBG fabrication. The properties and characteristics of the fabricated FBGs were investigated in order to design fibre-optic bending sensors. In this case, the analysis of FBG spectral characteristics and temperature sensitivity dependencies is crucial. The setup including a climatic chamber, an AQ6370D Optical Spectrum Analyser, an S5FC1550S-A2 SM Benchtop SLD Source and a computer was used for FBG spectral characteristics and temperature sensitivity measurement. Spectral characteristics of uniform and tilted FBGs were investigated within the temperature range from -40.6°C to 181.8°C. The following peaks in the spectral characteristics in the above-mentioned temperature range were chosen for analysis: the Bragg peak for uniform FBGs and such peaks as Bragg peak, Ghost peak and three peaks of certain wavelengths for tilted FBGs. The shifts of the analysed peaks in the spectral characteristics with temperature were observed. Temperature dependencies of wavelengths of the analysed peaks were obtained. It was shown that there is an approximately linear temperature dependence of the Bragg wavelength and other above-mentioned analysed peaks of certain wavelengths. The linear character of the investigated temperature dependencies of the fabricated FBGs allows for their use in sensor application. It was shown that temperature sensitivities of uniform and tilted FBGs were dependent on the temperature range chosen. Temperature sensitivities approximately equal to 11.1 – 11.4 pm / °C in a temperature range of 120.8 – 181.8 °C and approximately equal to 8.5 – 8.9 pm / °C in a temperature range of -40.6 – 20.7 °C for uniform and tilted FBGs were determined. Temperature sensitivities were dependent on certain wavelength and changed from 8.4 pm / °C to 10.1 pm / °C for particular wavelengths.
31 March 2024 in Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska
Prolonged exposure to elevated temperatures exceeding 47°C, which can occur during root canal obturation, can cause damage of both dental and bone tissues. In order to study the temperature distribution on the surface of the tooth root a temperature measuring device with cold-junction compensation is proposed. For in vitro measurement of the temperature distribution on the surface of the tooth, 8 thermocouples placed in direct contact with the cementum of the tooth were used. In order to eliminate the cold-junction temperature variations, the temperature equilibration device and RTD were used. The suggested linear approximation for the thermocouples' conversion function provides a nonlinearity relative error of less than 0.05% for K-type thermocouples and 0.07% for J-type thermocouples over the temperature range from 20 to 60°C.
30 December 2024 in Security of Infocommunication Systems and Internet of Things
The article describes digital and analogue methods for linearising the conversion function of thermoresistive transducers, with a detailed analysis of analogue methods. Analogue methods for linearising bridge circuits and measurement circuits based on passing a reference current through a resistance temperature detector (RTD) are considered. Linearisation of bridge circuits is based on the formation of the compensating supply voltage of the bridge circuit, which depends on the change in the measured temperature. When using the measurement method based on passing a reference current through an RTD, nonlinearity compensation is achieved by changing the conversion coefficient of the measuring signal or passing an additional current through the RTD, which linearly depends on the value of the RTD’s voltage change (measured temperature value). When passing an additional compensation current through the RTD, the nonlinearity error is not grater than 0.1°C in the range of 0…800°C, and the schematic diagram of the measuring transducer contains a minimum number of elements, which allows to increase its reliability. In general, the choice of a linearisation method depends on the requirements for accuracy, operation rate and resource limitations of the measuring system.
1 January 2020 in Scientific journal of the Ternopil national technical university
The problem of developing a universal signal converter for the construction of integrated sensors in data fusion concept is solved. Considering the requirements of modern microcircuit technique, in particular for sensory devices of the Internet of Things, the signal path of the synthesized sensors is implemented based on PSoC of 5LP Family Cypress. The testing of the developed system was carried out in the process of realization the integrated sensors of thermal analysis, optoelectronics, magnetic tracking and impedance spectroscopy.