Ya-Ming Tian

Ya-Ming Tian

Auto-generated profile, based on publicly available information

Ya-Ming Tian

Dalian University of Technology

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 October 2021 in Measurement Science and Technology
Verified
Journal Article
Closed access
YTYa-Ming Tian
Ya-Ming Tian
JXJie Xiong
Jie Xiong
GWGang Wang
Gang Wang
CJCheng Jiang
Cheng Jiang
SZSheng Zhang
Sheng Zhang
Wen-Long LiWen-Long Li
Wen-Long Li
Robot accurate positioning is a key task in robot-assisted casting process. The usual approach to improve positioning accuracy by the laser tracker is uneconomical and has low operability due to the on-site harsh environment (high vibration, cramped space, etc). In this paper, a novel approach is proposed to correct specific robot poses, where a 3D (three-dimensional) scanner is used to measure an array of standard balls in a robot 3D measurement system. The objective function is established with the help of a definition of the conversion between a 4 × 4 homogeneous transformation matrix and a 6D (six-dimensional) vector. In that definition, robot pose (position and orientation of the robot’s end-effector) parameters are used instead of robot kinematics parameters (Denavit-Hartenberg parameters). Simulation and practical experiments are performed to test the effect of this approach on pose correction. By using this approach, the average diameter error of reconstructed standard balls is less than 0.1 mm, which can meet the precision requirements in robot-assisted casting process.

7 June 2024 in IEEE/ASME Transactions on Mechatronics
Verified
Journal Article
Closed access
JZJin-Hua Zhang
Jin-Hua Zhang
Wen-Long LiWen-Long Li
Wen-Long Li
RCRui Chen
Rui Chen
XZXue-Song Zheng
Xue-Song Zheng
YTYa-Ming Tian
Ya-Ming Tian
YWYi Wan
Yi Wan
Accurate calibration of imaging parameters is the key to achieve 3-D scanning in underwater environment. However, the methods based on perspective principle have insufficient precision because of the multilayer refraction caused by encapsulated window. In this article, an accurate calibration method for pose of camera, pose of window, and refractive index of water (RIOW) is proposed. A new derivation for closed solution based on the coplanar and flat refractive constraints is derived to solve the problem that unknown RIOW is coupled into calculation. In calibration, the problem of coplanar degeneration is solved and RIOW can be estimated by constructing high-order equation. The proposed method can analytically compute and simultaneously optimize all parameters including RIOW. Finally, simulations and practical experiments are carried out to validate the feasibility and superiority of the proposed method. It is observed that more parameters are estimated (RIOW included) and higher accuracy is achieved (improved by 30%) compared with existing methods.

23 May 2025 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
YTYa-Ming Tian
Ya-Ming Tian
Wen-Long LiWen-Long Li
Wen-Long Li
SCSheng Cao
Sheng Cao
Wei XuWei Xu
Wei Xu
Han DingHan Ding
Han Ding
The error field plays an essential role in improving the positioning accuracy of the distributed measurement system (DMS). The key is to identify and compensate the measurement systematic errors of the DMS. In this article, a novel error field construction method for the DMS by using the laser tracker is proposed. A coupled-chain error model (CCEM) is innovatively established by introducing a self-defined chain weight based on the accuracy discrepancy between the DMS and the laser tracker. The CCEM is used to identify the measurement systematic errors of the DMS, thereby constructing the error field for the DMS. By using the proposed method, the problem that the positioning accuracy of the DMS decreases as the increase of the measuring distance is addressed. Simulation and practical experiments are carried out to test the superiority of the proposed method. The experimental results show that compared with two state-of-the-art methods, the positioning accuracy of the DMS within the measuring range of $6\times 6$ m calculated by the proposed method is improved by more than 85% and 60%, respectively.

25 November 2024 in IEEE/ASME Transactions on Mechatronics
Verified
Journal Article
Closed access
YTYa-Ming Tian
Ya-Ming Tian
Wen-Long LiWen-Long Li
Wen-Long Li
SCSheng Cao
Sheng Cao
HZHai-Wen Zhang
Hai-Wen Zhang
Han DingHan Ding
Han Ding
Distributed measurement system (DMS) has shown great potential in pose measurement for the mobile target. One essential problem encountered in global measurement with DMS is that the relative poses among measurement nodes are unknown. In this article, the problem of orientation for DMS is formulated and a novel method for solving the relative poses is proposed. An original omnidirectional cooperative target is designed to assist in shortening the orientation time. The objective function is constructed on the Lie algebra, and an analytical method is proposed to solve the initial values. The iterative optimization is converted to the solution to improved bundle adjustment, and an adaptive penalty factor is defined to balance the terms to be optimized. The solvability analysis is also given and discussed in detail. Simulation and practical experiments are conducted to verify the superiority of the proposed method. It is observed that after a representative DMS is oriented by the proposed method, the pose error of measuring the mobile robot with the DMS is reduced by 81.98% and 59.08%, respectively, compared with two other state-of-the-art methods.

21 August 2025 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
YTYa-Ming Tian
Ya-Ming Tian
Wen-Long LiWen-Long Li
Wen-Long Li
HZHai-Wen Zhang
Hai-Wen Zhang
SCSheng Cao
Sheng Cao
Wei XuWei Xu
Wei Xu
Han DingHan Ding
Han Ding
Global precision control is the basis of the field large-scale measurement (FLM). The main purpose is to improve the overall measurement performance by establishing the enhanced reference system (ERS). In this article, a novel global precision control method for the FLM based on the uniformly minimum variance unbiased estimate (UMVUE) is proposed. A universal calculation model of the measurement uncertainty is explicitly derived. By minimizing the integrated measurement uncertainty, the weight matrix for estimating the ERS points is defined based on the UMVUE. An iterative optimization algorithm is proposed to obtain the optimal UMVUE of the ERS points. The anisotropy and inhomogeneity of the measurement errors associated with the ERS points are fully considered and analyzed in the proposed method, by which the registration error of the ERS points is reduced and the global precision of the FLM is improved greatly. Simulation and practical experiments are conducted to verify the superiority of the proposed method. The experimental results show that the proposed method surpasses the traditional best-fit of single station (BFSS) method and two state-of-the-art (SOTA) methods in global precision control. Meanwhile, the registration error determined based on the ground truth is reduced from 0.0302 mm to 0.0165 mm.

11 October 2023 in Measurement Science and Technology
Verified
Journal Article
Closed access
WYWen-Tao Yang
Wen-Tao Yang
BYBin Yang
Bin Yang
CJCheng Jiang
Cheng Jiang
YTYa-Ming Tian
Ya-Ming Tian
YLYang Lin
Yang Lin
Wen-Long LiWen-Long Li
Wen-Long Li
Robotic measurement is an essential task during downtime in the nuclear power underwater environment. However, the narrow operating space of the underwater nuclear environment brings about an enormous challenge about the efficiency and safety of robotic measurement. This paper proposes a novel path-generation method with local pruning and collision-free adjustment. The proposed method increases the distance between the path and obstacles and reduces the number of collision detections. This core idea is to calculate extreme value points and path feature points as well as the collision-free adjustment for a smooth path. Firstly, the path is divided into subintervals where interval’s endpoints are the extreme value points. Next, the path points are distinguished by path feature points in each subinterval. A two-level connection strategy is proposed to connect the path points among path feature points within the constraints of curvature and density. Then, the smooth path is adjusted to avoid obstacles. The use of extreme value points and path feature points contributes to increasing the efficiency of path generation and improving the safety of the robotic measurement. Simulations and practical experiments are carried out to validate the feasibility of the proposed method over another method. Path safety index (PSI) is defined to measure the distance between path and obstacles. The efficiency of path generation is improved by up to 101% and PSI is improved by up to 20.75%.