Sabrina Skov Hansen

Sabrina Skov Hansen

Auto-generated profile, based on publicly available information

Sabrina Skov Hansen

Department of Veterinary Clinical Sciences University of Copenhagen Copenhagen Denmark

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 October 2020 in Equine Veterinary Education
Verified
Journal Article
Open access
PDF file
SHS. Skov Hansen
S. Skov Hansen
CMC. Mattei
C. Mattei
HPH. Treffenberg Pettersson
H. Treffenberg Pettersson
MGMiłosz Grabski
Miłosz Grabski
Summary: This report describes successful surgical correction and long‐term survival of a case of large colon atresia in a 24‐h‐old Warmblood colt, referred with signs of unrelenting abdominal pain and a suspicion of meconium impaction. Radiographic and ultrasonographic examination was indicative of large colon meconium impaction with secondary ileus. Due to deterioration of the foal, surgery was recommended. An atretic segment was found between the left ventral and dorsal large (ascending) colon. A band of fibrous tissue with no identifiable lumen connected the segments. Surgical correction was done by performing a stapled side‐to‐side anastomosis. Twelve days after surgery, the foal was discharged. Twenty‐two months after discharge, the owner reported the foal developing as expected compared with its peers, but had a mild, self‐limiting episode of colic at 20 months of age.

23 August 2019 in Equine Veterinary Education
Verified
Journal Article
Closed access
PDF file
SHS. Skov Hansen
S. Skov Hansen
ULU. Lagerquist
U. Lagerquist
TTT. Tóth
T. Tóth

4 November 2025 in Equine Veterinary Journal
Verified
Journal Article
Open access
KKKarsten Key
Karsten Key
KBKatja Berg
Katja Berg
JKJakob Kirkegaard
Jakob Kirkegaard
KAKristian Ringkjær Andresen
Kristian Ringkjær Andresen
SHSabrina Skov Hansen
Sabrina Skov Hansen
Background: Computer vision‐based algorithms offer accessible alternatives for equine gait analysis but require thorough assessment under diverse conditions. Objectives: To evaluate a proprietary vision‐based algorithm's reliability in measuring vertical displacement signals (VDS) at the eye, withers and croup, alongside groundline estimation, for horses trotting on straight lines and circles under field conditions. Study Design: Cross‐sectional comparative study evaluating agreement, variability and reliability of a markerless computer vision algorithm. Methods: We obtained 67 handheld iPhone recordings from 37 horses. A vision‐based algorithm and independent manual annotation produced 2D anatomical keypoints on all frames of the recordings, which were processed to estimate a groundline and compute VDS and stride‐based maxima (Maxdiff) and minima (Mindiff) vertical differences. Mean signed error (MSE), mean absolute error (MAE) and Bland–Altman plots were used to compare detected and annotated data. Results: The frame level vertical keypoint accuracy was 4.5 mm (eye), 5.5 mm (croup) and 11.8 mm (withers), and the manual annotation error was averaged at 2.7 mm. At the stride level ( n = 1556), the overall mean absolute errors (MAEs) for both Maxdiff and Mindiff were 4.3 mm. The eye keypoint exhibited the lowest errors (2.9 mm Maxdiff, 3.0 mm Mindiff), while the withers error was 5.5 mm for both Maxdiff and Mindiff, and the croup showed 4.3 mm (Maxdiff) and 4.4 mm (Mindiff). Trial‐level ( n = 67) analysis, with below optimal number of strides per trial in this study, revealed lower overall absolute differences (Eye: 2.3 mm, Withers: 3.7 mm, Croup: 2.7 mm), indicating consistent performance across multiple strides. Subjective lameness scoring aligned with objective measures with some variation. Main Limitations: Groundline estimation accuracy was stress‐tested on treadmill data in another study. Further clinical comparison with established gait analysis systems is recommended. Conclusions: The algorithm robustly measured vertical displacements under varied conditions.

16 January 2026 in Equine Veterinary Journal
Verified
Journal Article
Open access
KKKarsten Key
Karsten Key
JKJakob Kirkegaard
Jakob Kirkegaard
KBKatja Berg
Katja Berg
KAKristian Ringkjær Andresen
Kristian Ringkjær Andresen
SHSabrina Skov Hansen
Sabrina Skov Hansen
Background: A handheld smartphone‐based computer vision algorithm (RealHorse® [RH]) offers accessible alternatives for equine gait analysis but requires validation against a gold‐standard three‐dimensional multicamera optical motion capture system (Qualisys® [QS]). Objectives: To evaluate the accuracy and precision of RH in measuring vertical displacement signals (VDS) at the eye, withers, back and croup in horses trotting on a straight line and on a circle. Study Design: Cross‐sectional comparative validation study of a markerless computer vision algorithm. Methods: Fifty‐nine horses were recorded while trotting on a straight line and 24 were lunged on a circle. RH detected two‐dimensional anatomical keypoints on each frame, which were used to estimate a dynamic groundline and compute ground relative VDS with stride‐based difference in maxima (Maxdiff) and minima (Mindiff). QS provided synchronous ground‐relative VDS reference values. Agreement was evaluated using mean signed error, mean absolute error and Bland–Altman analysis. Results: On the straight line ( n = 2620 strides), the pooled stride‐level MAE for Maxdiff and Mindiff was 3.8 mm. Keypoint‐specific errors were 5.1 mm (eye), 4.3 mm (withers) and 3.0 mm (croup). On the circle ( n = 2419 strides), pooled stride‐level error increased to 5.5 mm. Trial‐level analysis ( n = 58 trials) showed much lower errors: 1.4 mm for both eye and withers and 1.1 mm for croup. On the circle ( n = 24 trials), trial‐level errors were higher, with 2.8 mm for the eye, 1.8 mm for the withers and 3.3 mm for the croup. The back keypoint consistently showed the lowest errors across both stride and trial levels. Main Limitations: RH measurements of the croup Mindiff during circling resulted in higher values and showed the largest error. Conclusions: RH measured vertical displacement of all keypoints with high accuracy and precision (trial‐level MAE 1.1–1.4 mm straight, 1.8–3.3 mm circle), supporting its use for equine gait analysis.

30 December 2025 in Veterinary Medicine and Science
Verified
Journal Article
Open access
KKKarsten Key
Karsten Key
KBKatja Berg
Katja Berg
JKJakob Kirkegaard
Jakob Kirkegaard
KAKristian Ringkjær Andresen
Kristian Ringkjær Andresen
SHSabrina Skov Hansen
Sabrina Skov Hansen
Background: Equine lameness diagnosis largely relies on subjective visual assessments, which can be biased. Although marker‐based methods, force plates and inertial measurement units (IMUs) provide objective measurements, they require specialized setups. Vision‐based algorithms offer a portable, markerless alternative, but their accuracy needs thorough testing. Objectives: To evaluate a custom vision‐based algorithm for estimating the groundline across multiple camera angles, including handheld use in horses trotting on a treadmill. Study design: Experimental comparative study. Methods: Eight Standardbred trotter mares were recorded trotting on a high‐speed treadmill using seven iPhones positioned at various heights and angles, including a handheld device. A trained deep neural network algorithm placed 2D keypoints on each video frame. Vertical Displacement Signals (VDS) for the eye, withers and croup (tuber sacrale) were computed relative to either an algorithm‐estimated or a fixed treadmill groundline. Maximum (Maxdiff) and minimum (Mindiff) stride values were compared using Bland–Altman analysis, scatter plots and histograms. The effect of handheld use on variability and accuracy was assessed by comparing results from a handheld camera to those from a static camera. Results: Groundline estimation closely matched the fixed reference, exhibiting near‐zero mean angle error and low mean average error (MAE = 0.45°; n = 242.192). Maxdiff and Mindiff stride‐level ( n = 36.981) MAE were 0.5 mm, with clinically acceptable additional variability introduced by handheld use at the trial level (Maxdiff and Mindiff MAE < 1.8 mm; n = 357). Main limitations: Treadmill‐based data and a single breed/coat colour may limit generalizability to other settings. Conclusions: The vision‐based algorithm accurately estimates the groundline and stride VDS parameters from various camera setups, including handheld. Further validation in diverse environments and against other objective gait analysis systems is recommended.

29 August 2019 in Veterinary Surgery
Verified
Journal Article
Closed access
PDF file
SHSabrina Skov Hansen
Sabrina Skov Hansen
TTTamás Tóth
Tamás Tóth