Adedoyin Inaolaji

Adedoyin Inaolaji

Auto-generated profile, based on publicly available information

Adedoyin Inaolaji

Electrical Engineering Department, State University of New York at Buffalo, Buffalo, NY, USA

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 June 2024 in Journal of Energy Storage
Verified
Journal Article
Closed access
AIAdedoyin Inaolaji
Adedoyin Inaolaji
XWXuan Wu
Xuan Wu
RRRajarshi Roychowdhury
Rajarshi Roychowdhury
RSRaiford Smith
Raiford Smith

15 June 2022 in IEEE Transactions on Industry Applications
Verified
Journal Article
Closed access
ASAlper Savasci
Alper Savasci
AIAdedoyin Inaolaji
Adedoyin Inaolaji
SPSumit Paudyal
Sumit Paudyal
This article develops a two-stage volt-VAr control strategy coordinating the discrete controls of legacy grid devices and the operation of smart inverters (SIs) in power distribution grids with high penetration of photovoltaic generation. The first stage dispatch problem optimally coordinates the tap settings of on-load tap changers, on / off status of shunt capacitor banks, and SIs’ active power output. The second stage incorporates the SI volt-VAr mode, i.e., $\mathbf{Q(V)}$ as per IEEE-1547, and an adaptive volt-VAr droop function, $\mathbf{Q(\Delta V)}$ , to dispatch the SI reactive power generation. Both dispatch problems are formulated as mixed-integer linear programming problems to maintain tractable formulations and reduce the complexity and computational burden that usually arise when solving large-scale optimal power flow problems. The proposed two-stage strategy is tested on a modified IEEE 123-bus system considering different droop settings. The dispatch strategy augmented with $\mathbf{Q(\Delta V)}$ droop outperforms the model with only $\mathbf{Q(V)}$ droop in stabilizing the PCC voltage while maintaining less active power curtailment.

9 June 2022 in IEEE Transactions on Industry Applications
Verified
Journal Article
Closed access
AIAdedoyin Inaolaji
Adedoyin Inaolaji
ASAlper Savasci
Alper Savasci
SPSumit Paudyal
Sumit Paudyal
High penetration of photovoltaic (PV) generators in active distribution networks (ADNs) cause overvoltage due to reverse power flow. Smart inverter (SI) functionalities can be configured to provide efficient voltage regulation and reactive power support in ADNs. Moreover, the mismatch between peak PV generation and peak demand make battery energy storage systems (BESSs) increasingly important assets in power grids, capable of enabling higher penetration of renewable energy resources by mitigating the system-wide effects of PV intermittency. In this work, we propose the inclusion of local piecewise Volt-VAr and Volt-Watt droop functions of PV (as per the IEEE-1547) as constraints in a multiperiod distribution grid optimal power flow (DOPF) formulation. This approach is an efficient voltage control method for unbalanced multiphase networks, making the inverter dispatch solutions abide by the IEEE-1547 standard and therefore suitable at the local inverter controller level. We adopt a well-known LinDist3Flow version of DOPF, and the resulting multiperiod DOPF becomes a mixed-integer linear programming problem. Simulations on the IEEE 123-node feeder with 15 utility-scale PV and BESS inverters validate the efficacy of the proposed formulation in performing effective voltage regulation and control that abide by the IEEE-1547 standard. The case studies show that SI droop-integrated DOPF can ensure reduced variation in bus voltages, reducing the risk of voltage violations, and net load smoothing can be achieved with BESS, reducing the disparity between inexpensive midday and expensive evening energy price.

5 June 2023 in IEEE Transactions on Industry Applications
Verified
Journal Article
Closed access
AIAdedoyin Inaolaji
Adedoyin Inaolaji
ASAlper Savasci
Alper Savasci
SPSumit Paudyal
Sumit Paudyal
SKSukumar Kamalasadan
Sukumar Kamalasadan
The use of distributed optimization for solving optimal power flow (OPF) problems in distribution networks is increasing as the number of controllable devices and the span of service areas increase. However, the performance of the distributed optimization algorithm largely depends on the availability and quality of communication links between the computing entities. In this paper, we evaluate the performance of the alternating direction method of multipliers (ADMM) for solving the OPF problem for volt-VAr optimization (VVO) under non-ideal communication. The overall problem is formulated by considering the unbalanced operation of multi-phase distribution networks. The algorithm's performance is first analyzed, assuming there is an ideal communication between computing entities, which serves as a benchmark for further analysis. Then, two non-ideal communication models, namely (1) sporadic communication failure and (2) communication under a noisy transmission, are applied to the information exchange architecture of the ADMM. Extensive numerical experiments are conducted with two test systems, the IEEE 123-bus feeder and a 2522-bus network scaled down from the IEEE 8500-bus system; these are used to evaluate the performance of the algorithm. The results indicate that the ADMM-based distributed VVO algorithm has deteriorated performance under high levels of communication failure and high levels of noise injection. Additionally, although the centralized-VVO counterpart has some computational superiority when the overall problem is convex and no communication impairments exist, the distributed-VVO has superior immunized solution performance under realistic communication constraints.

8 September 2023 in IEEE Transactions on Industry Applications
Verified
Journal Article
Closed access
ASAlper Savasci
Alper Savasci
AIAdedoyin Inaolaji
Adedoyin Inaolaji
SPSumit Paudyal
Sumit Paudyal
A bang-bang type control rule is typically adopted to automate the tap-changing process of on-load tap changers (OLTCs) and step voltage regulators (SVRs). The control rule is mainly characterized by a dead band parameter affecting voltage regulation performance. Due to the intermittent large-scale photovoltaic (PV) penetration, dynamic voltage fluctuations are induced along the distribution feeder, leading to frequent tap switching and equipment wear and tear. This paper proposes an optimization-based dead band tuning method to reduce the number of tap switching and lengthen the economic use-life of the regulation equipment. Unlike existing works that often ignore the local controller mechanism of tap changers, this work extends the modeling efforts by formulating the dead band tuning as a distribution system optimal power flow (DOPF) problem by considering the unbalanced characteristics of multi-phase feeders. The overall DOPF is formulated as a mixed- integer linear program (MILP) to minimize the daily total number of tap switching and the amount of curtailed energy from the PV-based inverters while maintaining voltage regulation performance. Extensive numerical tests conducted on the IEEE 13- bus and IEEE 123- bus test networks suggest that the number of tap switching can further be minimized with the use of a dynamic dead band tuning strategy.

2 August 2020
Verified
Conference Paper
Closed access
ASAlper Savasci
Alper Savasci
AIAdedoyin Inaolaji
Adedoyin Inaolaji
SPSumit Paudyal
Sumit Paudyal
Computational tractability and scalability are general concerns of Unit Commitment (UC) formulations given the inherent non-convex nature of the problem. Mixed-integer linear programming (MILP) version of UC is very common in modern Energy Management Systems. Lately, mixed-integer second order cone programming (MISOCP) versions of UC are also gaining research attention. To this end, this paper presents a comparative analysis of MILP and MISOCP based UC formulations with and without network constraints. Extensive numerical simulations are performed to investigate accuracy and scalability of MISOCP and MILP UC formulations with several test cases up to 1,000 generating units. Results show that the MISOCP UC model is generally superior to its MILP counterpart in terms of costs. On the computational time, MISOCP performed superior compared to MILP for large power systems. However, for small systems, MILP UC model performed very similar to MISOCP version in terms of the computational time.