Carolin M. Geitner

Carolin M. Geitner

Auto-generated profile, based on publicly available information

Carolin M. Geitner

Institute for Computational Mechanics, Department of Engineering Physics & Computation, TUM School of Engineering and Design Technical University of Munich Garching b. Muenchen Germany

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 July 2023 in International Journal for Numerical Methods in Biomedical Engineering
Verified
Journal Article
Open access
CGCarolin M. Geitner
Carolin M. Geitner
Tobias BecherTobias Becher
Tobias Becher
IFInéz Frerichs
Inéz Frerichs
NWNorbert Weiler
Norbert Weiler
JBJason Bates
Jason Bates
WWWolfgang A. Wall
Wolfgang A. Wall
We present a new approach for physics‐based computational modeling of diseased human lungs. Our main object is the development of a model that takes the novel step of incorporating the dynamics of airway recruitment/derecruitment into an anatomically accurate, spatially resolved model of respiratory system mechanics, and the relation of these dynamics to airway dimensions and the biophysical properties of the lining fluid. The importance of our approach is that it potentially allows for more accurate predictions of where mechanical stress foci arise in the lungs, since it is at these locations that injury is thought to arise and propagate from. We match the model to data from a patient with acute respiratory distress syndrome (ARDS) to demonstrate the potential of the model for revealing the underlying derangements in ARDS in a patient‐specific manner. To achieve this, the specific geometry of the lung and its heterogeneous pattern of injury are extracted from medical CT images. The mechanical behavior of the model is tailored to the patient's respiratory mechanics using measured ventilation data. In retrospective simulations of various clinically performed, pressure‐driven ventilation profiles, the model adequately reproduces clinical quantities measured in the patient such as tidal volume and change in pleural pressure. The model also exhibits physiologically reasonable lung recruitment dynamics and has the spatial resolution to allow the study of local mechanical quantities such as alveolar strains. This modeling approach advances our ability to perform patient‐specific studies in silico, opening the way to personalized therapies that will optimize patient outcomes.

30 July 2024 in Inverse Problems
Verified
Journal Article
Open access
MDMaximilian Dinkel
Maximilian Dinkel
CGCarolin M Geitner
Carolin M Geitner
GRGil Robalo Rei
Gil Robalo Rei
JNJonas Nitzler
Jonas Nitzler
WWWolfgang A Wall
Wolfgang A Wall
Solving inverse problems using Bayesian methods can become prohibitively expensive when likelihood evaluations involve complex and large scale numerical models. A common approach to circumvent this issue is to approximate the forward model or the likelihood function with a surrogate model. But also there, due to limited computational resources, only a few training points are available in many practically relevant cases. Thus, it can be advantageous to model the additional uncertainties of the surrogate in order to incorporate the epistemic uncertainty due to limited data. In this paper, we develop a novel approach to approximate the log likelihood by a constrained Gaussian process based on prior knowledge about its boundedness. This improves the accuracy of the surrogate approximation without increasing the number of training samples. Additionally, we introduce a formulation to integrate the epistemic uncertainty due to limited training points into the posterior density approximation. This is combined with a state of the art active learning strategy for selecting training points, which allows to approximate posterior densities in higher dimensions very efficiently. We demonstrate the fast convergence of our approach for a benchmark problem and infer a random field that is discretized by 30 parameters using only about 1000 model evaluations. In a practically relevant example, the parameters of a reduced lung model are calibrated based on flow observations over time and voltage measurements from a coupled electrical impedance tomography simulation.

30 November 2023 in International Journal for Numerical Methods in Biomedical Engineering
Verified
Journal Article
Open access
CGCarolin M. Geitner
Carolin M. Geitner
LKLea J. Köglmeier
Lea J. Köglmeier
IFInéz Frerichs
Inéz Frerichs
PLPatrick Langguth
Patrick Langguth
MLMatthias Lindner
Matthias Lindner
WWWolfgang A. Wall
Wolfgang A. Wall
We present a novel computational model for the dynamics of alveolar recruitment/derecruitment (RD), which reproduces the underlying characteristics typically observed in injured lungs. The basic idea is a pressure‐ and time‐dependent variation of the stress‐free reference volume in reduced dimensional viscoelastic elements representing the acinar tissue. We choose a variable reference volume triggered by critical opening and closing pressures in a time‐dependent manner from a straightforward mechanical point of view. In the case of (partially and progressively) collapsing alveolar structures, the volume available for expansion during breathing reduces and vice versa, eventually enabling consideration of alveolar collapse and reopening in our model. We further introduce a method for patient‐specific determination of the underlying critical parameters of the new alveolar RD dynamics when integrated into the tissue elements, referred to as terminal units, of a spatially resolved physics‐based lung model that simulates the human respiratory system in an anatomically correct manner. Relevant patient‐specific parameters of the terminal units are herein determined based on medical image data and the macromechanical behavior of the lung during artificial ventilation. We test the whole modeling approach for a real‐life scenario by applying it to the clinical data of a mechanically ventilated patient. The generated lung model is capable of reproducing clinical measurements such as tidal volume and pleural pressure during various ventilation maneuvers. We conclude that this new model is an important step toward personalized treatment of ARDS patients by considering potentially harmful mechanisms—such as cyclic RD and overdistension—and might help in the development of relevant protective ventilation strategies to reduce ventilator‐induced lung injury (VILI).

5 February 2026 in Physiological Measurement
Verified
Journal Article
Open access
MLMaximilian Ludwig
Maximilian Ludwig
CGCarolin M Geitner
Carolin M Geitner
ASArmin Sablewski
Armin Sablewski
IFInéz Frerichs
Inéz Frerichs
Tobias BecherTobias Becher
Tobias Becher
WWWolfgang A Wall
Wolfgang A Wall
Objective: Time-difference electrical impedance tomography (EIT) is gaining widespread use for bedside lung monitoring in intensive care patients suffering from lung-related diseases. It involves collecting voltage measurements from electrodes placed on the patient’s thorax, which are then used to reconstruct impedance images. This study investigates how incorporating anatomical information from CT data into the widely used GREIT reconstruction algorithm affects EIT images and improves their interpretability. Approach: Based on clinically motivated lung state scenarios, we simulated EIT measurements to assess how the GREIT parameters influence the result of EIT image reconstruction, particularly with respect to noise performance and image accuracy. We introduce quality measures that allow us to perform a quantitative assessment of reconstruction quality. We incorporate the anatomical features of a patient from CT data by customizing the background conductivity and the distribution of GREIT training targets. Main results: Our analysis confirmed that unphysiological background conductivity assumptions can lead to misleading EIT images, whereas physiological values, although more accurate, come with higher noise sensitivity. By increasing the number of GREIT training targets inside the lung and adapting the respective weighting radius, we significantly improved the anatomical accuracy of the EIT images. When applied to clinical EIT data from a representative ARDS patient, these adjustments in the reconstruction setup substantially enhanced the interpretability of the resulting EIT images. Significance: Incorporating CT-based anatomical data in the GREIT reconstruction significantly enhances the clinical applicability of EIT in lung monitoring. The improved interpretability of EIT images facilitates better-informed clinical decisions and the individualized adjustment of ventilation strategies for critically ill patients.