Rob Veenhof

Rob Veenhof

Auto-generated profile, based on publicly available information

Rob Veenhof

European Organization for Nuclear Research (CERN), 1211 Geneva 23, Switzerland

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2024 in Journal of Instrumentation
Verified
Journal Article
Open access
XWX. Wang
X. Wang
RAR. Aleksan
R. Aleksan
YAY. Angelis
Y. Angelis
JBJ. Bortfeldt
J. Bortfeldt
FBF. Brunbauer
F. Brunbauer
YZY. Zhou
Y. Zhou
The PICOSEC Micromegas (MM) detector is a precise timing gaseous detector based on a MM detector operating in a two-stage amplification mode and a Cherenkov radiator. Prototypes equipped with cesium iodide (CsI) photocathodes have shown promising time resolutions as precise as 24 picoseconds (ps) for Minimum Ionizing Particles. However, due to the high hygroscopicity and susceptibility to ion bombardment of the CsI photocathodes, alternative photocathode materials are needed to improve the robustness of PICOSEC MM. Diamond-like Carbon (DLC) film have been introduced as a novel robust photocathode material, which have shown promising results. A batch of DLC photocathodes with different thicknesses were produced and evaluated using ultraviolet light. The quantum efficiency measurements indicate that the optimized thickness of the DLC photocathode is approximately 3 nm. Furthermore, DLC photocathodes show good resistance to ion bombardment in aging test compared to the CsI photocathode. Finally, a PICOSEC MM prototype equipped with DLC photocathodes was tested in muon beams. A time resolution of around 42 ps with a detection efficiency of 97% for 150 GeV/c muons were obtained. These results indicate the great potential of DLC as a photocathode for the PICOSEC MM detector.

11 December 2024 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Open access
MLM. Lisowska
M. Lisowska
RAR. Aleksan
R. Aleksan
YAY. Angelis
Y. Angelis
SAS. Aune
S. Aune
JBJ. Bortfeldt
J. Bortfeldt
YZY. Zhou
Y. Zhou

1 November 2022 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Open access
MLM. Lisowska
M. Lisowska
JBJ. Bortfeldt
J. Bortfeldt
FBF. Brunbauer
F. Brunbauer
GFG. Fanourakis
G. Fanourakis
KFK.J. Floethner
K.J. Floethner
YZY. Zhou
Y. Zhou

1 March 2025 in Journal of Instrumentation
Verified
Journal Article
Closed access
YMY. Meng
Y. Meng
RAR. Aleksan
R. Aleksan
YAY. Angelis
Y. Angelis
JBJ. Bortfeldt
J. Bortfeldt
FBF. Brunbauer
F. Brunbauer
YZY. Zhou
Y. Zhou
PICOSEC Micromegas (MM) is a precise timing gaseous detector based on a Cherenkov radiator coupled with a semi-transparent photocathode and an MM amplifying structure. The detector concept was successfully demonstrated through a single-channel prototype, achieving sub-25 ps time resolution with Minimum Ionizing Particles (MIPs). A series of studies followed, aimed at developing robust, large-area, and scalable detectors with high time resolution, complemented by specialized fast-response readout electronics. This work presents recent advancements towards large-area resistive PICOSEC MM, including 10 × 10 cm2 area prototypes and a 20 × 20 cm2 prototype, which features the jointing of four photocathodes. The time resolution of these detector prototypes was tested during the test beam, achieved a timing performance of around 25 ps for individual pads in MIPs. Meanwhile, customized electronics have been developed dedicated to the high-precision time measurement of the large-area PICOSEC MM. The performance of the entire system was evaluated during the test beam, demonstrating its capability for large-area integration. These advancements highlight the potential of PICOSEC MM to meet the stringent requirements of future particle physics experiments.

1 July 2024 in Journal of Instrumentation
Verified
Journal Article
Open access
KFK.J. Flöthner
K.J. Flöthner
LSL. Scharenberg
L. Scharenberg
ABA. Brask
A. Brask
FBF. Brunbauer
F. Brunbauer
FGF. Garcia
F. Garcia
RVR. Veenhof
R. Veenhof
Gas Electron Multipliers (GEMs) are used in many particle physics experiments, employing their `standard' configuration with amplification holes of 140 μm pitch in a hexagonal pattern. However, the collection of the charge cloud from the primary ionisation electrons from the drift region of the detector into the GEM holes affects the position information from the initial interacting particle. In this paper, the results from studies with a triple-GEM detector with an X-Y-strip readout anode are presented. It is demonstrated that GEMs with a finer hole pitch of here 90 μm improve the detector's spatial resolution. Within these studies, also the impact of the front-end electronics on the spatial resolution was investigated, which is briefly discussed in the paper.

1 May 2024 in Journal of Instrumentation
Verified
Journal Article
Open access
LSL. Scharenberg
L. Scharenberg
FBF. Brunbauer
F. Brunbauer
HDH. Danielsson
H. Danielsson
ZFZ. Fang
Z. Fang
KFK.J. Flöthner
K.J. Flöthner
YZY. Zhou
Y. Zhou
Micro-Pattern Gaseous Detectors (MPGDs) with resistive anode planes provide intrinsic discharge robustness while maintaining good spatial and time resolutions. Typically read out with 1D strips or pad structures, here the characterisation results of resistive anode plane MPGDs with 2D strip readout are presented. A µRWELL prototype is investigated in view of its use as a reference tracking detector in a future gaseous beam telescope. A MicroMegas prototype with a fine-pitch mesh (730 line-pairs-per-inch) is investigated, both for comparison and to profit from the better field uniformity and thus the ability to operate the detector more stable at high gains. Furthermore, the measurements are another application of the RD51 VMM3a/SRS electronics.