Heiner Daerr

Heiner Daerr

Auto-generated profile, based on publicly available information

Heiner Daerr

Philips Innovative Technologies, Hamburg, Germany

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 January 2022 in Journal of Medical Imaging
Verified
Journal Article
Closed access
PDF file
WCWenchao Cao
Wenchao Cao
NSNadav Shapira
Nadav Shapira
AMAndrew Maidment
Andrew Maidment
HDHeiner Daerr
Heiner Daerr
PNPeter B. Noël
Peter B. Noël
Purpose: Dual-contrast protocols are a promising clinical multienergy computed tomography (CT) application for focal liver lesion detection and characterization. One avenue to enable multienergy CT is the introduction of photon-counting detectors (PCD). Although clinical translation is highly desired because of the diagnostic benefits of PCDs, it will still be a decade or more before they are broadly available. In our work, we investigated an alternative solution that can be implemented on widely used conventional CT systems (single source and integrating detector) to perform multimaterial spectral decomposition for dual-contrast imaging. Approach: We propose to slowly alternate the x-ray tube voltage between 3 kVp levels so each kVp level covers a few degrees of gantry rotation. This leads to the challenge of sparsely sampled projection data in each energy level. Performing the material decomposition (MD) in the sinogram domain is not directly possible as the projection images of the three energy levels are not angularly aligned. In order to overcome this challenge, we developed a convolutional neural network (CNN) framework for sparse sinogram completion (SC) and MD. To evaluate the feasibility of the slow kVp switching scheme, simulation studies of an abdominal phantom, which included liver lesions, were conducted. Results: The line-integral SC network yielded sinograms with a pixel-wise RMSE < 0.05 of the line-integrals compared to the ground truth. This provided acceptable image quality up to a switching angle of 9 deg per kVp. The MD network we developed allowed us to differentiate iodine and gadolinium in the sinogram domain. The average relative quantification errors for iodine and gadolinium were below 10%. Conclusions: We developed a slow triple kVp switching data acquisition scheme and a CNN-based data processing pipeline. Results from a digital phantom validation illustrate the potential for future applications of dual-contrast agent protocols on practically available single-energy CT systems.

1 April 2022 in Journal of Micro/Nanopatterning, Materials, and Metrology
Verified
Journal Article
Open access
PDF file
MRMichael Richter
Michael Richter
TBThomas Beckenbach
Thomas Beckenbach
HDHeiner Daerr
Heiner Daerr
SPSven Prevrhal
Sven Prevrhal
MBMartin Börner
Martin Börner
PMPascal Meyer
Pascal Meyer
Clinical diagnostic x-ray imaging is currently based on the principle of differences of x-ray attenuation between tissues. Whereas attenuation contrast is often insufficient to allow differentiation between tissues such as cancer lesions in soft tissue or pathologic changes in the lung, research points to phase-contrast, and dark-field x-ray imaging as an option to overcome this limitation, with clinical1 – 5 as well as industrial applicability.6 Currently, the most promising technology to do phase contrast and dark-field imaging is interferometry using a Talbot–Lau interferometer, which requires microstructured gratings.7,8

10 August 2026 in medRxiv
Verified
Preprint
Open access
PDF file
OSOlivia F. Sandvold
Olivia F. Sandvold
RPRoland Proksa
Roland Proksa
APAmy E. Perkins
Amy E. Perkins
HDHeiner Daerr
Heiner Daerr
TKThomas Koehler
Thomas Koehler
PNPeter B. Noël
Peter B. Noël
Spectral computed tomography (CT) is a burgeoning quantitative imaging technique with applications in oncologic diagnostics, prognostic prediction, tissue perfusion studies, and treatment follow-up. While normalized iodine concentration values have been correlated with microenvironmental biophysical changes, obtaining accurate iodine concentrations, particularly at low concentrations remains difficult due to varying spectral CT instrumentation performance. Hybrid spectral CT systems, combining multiple spectral CT instrumentation techniques, address these quantitation insufficiencies by increasing spectral separation but have not been evaluated on a clinically analogous platform. We validate a hybrid spectral CT system, comprised of clinical-grade components, acquiring four distinct effective spectra and applying efficient noise-reducing weighting schemes to compare iodine noise and bias against conventional kVp-Switching (kVp-S). Two tube current levels (50, 350 mA) and three duty cycle ratios (33/67, 50/50, 75/25) were implemented to elucidate radiation dose exposure and kVp-S parameterization impact. A standard quality assurance (QA) and patient-derived, abdominal IodinePrint phantom were scanned on the system. The average absolute bias in iodine density images of the QA phantom was comparable across acquisition techniques, below 0.5 mg/mL, while quantitative noise improved by 22% using noise-optimized weighting schemes. In the IodinePrint phantom aorta and pancreas structures, the noise-optimized weighting scheme increased signal-to-noise ratio (SNR) by 1.3x compared to kVp-S alone. These results highlight the increased precision of hybrid, multi-channel spectral CT systems and motivate CT designs that enable robust CT biomarker development.