Accurate synchronized sampling is essential for power grid monitoring instruments, but its precision is greatly affected by sampling time errors (STEs) resulting from oscillator frequency drift. However, existing methods to mitigate STEs often rely on additional auxiliary devices or involve complex hardware control processes. Therefore, this article introduces a novel sampling scheme that effectively mitigates the impact of STEs without the aforementioned restrictions. First, the actual sampling interval is estimated via a counter triggered by the satellite timing reference. Second, the actual sampling interval is fed into the Diophantine approximation method to determine the sampling interval conversion ratio (SICR). Finally, an IFB is constructed according to the SICR to rectify the sampling data contaminated by the STE. A series of simulation and hardware experiments are conducted to verify the effectiveness of the proposed DA-IFB. The test results demonstrate that the proposed DA-IFB is comparable to the state-of-the-art synchronized sampling method without any additional requirements, with maximum sampling error significantly mitigating from $2.16 \times 10^{-3}$$\mathrm{V}$ to $7.18 \times 10^{-5}$$\mathrm{V}$ .
8 September 2025 in IEEE Transactions on Smart Grid
This article presents a Tunnel magneto-resistance-based Double air-gap Zero magnetic field (TDZ) current sensor, designed for measuring wideband disturbances in Renewable Energy Sources (RES)-based power systems. Conventional current transformers face limitations in accuracy and dynamic measurement performance due to inherent structural and material constraints. To overcome these limitations, a zero magnetic environment is designed by fusing the coil and feedback circuit with the motivation of approximating the actual magnetic field strength. Next, double air gap and closed-loop structures are formed to mitigate eccentricity errors, resulting in a 39-fold improvement in linearity compared to open-loop designs. Finally, by integrating the TDZ sensor, a wideband disturbance recorder prototype, referred to as the Grid Situational Awareness Device (GSAD), is implemented to enable high-fidelity phasor measurements. Extensive experiments validate its superior performance under steady-state, dynamic, and wideband disturbance conditions. The results demonstrate that the measurement capabilities surpass those of typical sensors, achieving a linearity of 0.03% and a full-scale accuracy of 0.038%. The frequency error and total vector error of the TDZ-GSAD are as low as 0.2 mHz and 0.039%, respectively.