Mario G. Bernal-Torres

Mario G. Bernal-Torres

Auto-generated profile, based on publicly available information

Mario G. Bernal-Torres

Facultad de Ingeniería, Av. Dr. Manuel Nava No. 8, Universidad Autónoma de San Luis Potosí, 78290 San Luis Potosí, SLP, Mexico

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 April 2018 in Journal of Healthcare Engineering
Verified
Journal Article
Open access
PDF file
MBMario G. Bernal-Torres
Mario G. Bernal-Torres
HMHugo Medellin-Castillo
Hugo Medellin-Castillo
JAJuan C. Arellano-González
Juan C. Arellano-González
Passive knee prostheses require a significant amount of additional metabolic energy to carry out a gait cycle, therefore affecting the natural human walk performance. Current active knee prostheses are still limited because they do not reply with accuracy of the natural human knee movement, and the time response is relatively large. This paper presents the design and control of a new biomimetic-controlled transfemoral knee prosthesis based on a polycentric-type mechanism. The aim was to develop a knee prosthesis able to provide additional power and to mimic with accuracy of the natural human knee movement using a stable control strategy. The design of the knee mechanism was obtained from the body-guidance kinematics synthesis based on real human walking patterns obtained from computer vision and 3D reconstruction. A biomechanical evaluation of the synthesized prosthesis was then carried out. For the activation and control of the prosthesis, an echo-control strategy was proposed and developed. In this echo-control strategy, the sound side leg is sensed and synchronized with the activation of the knee prosthesis. An experimental prototype was built and evaluated in a test rig. The results revealed that the prosthetic knee is able to mimic the biomechanics of the human knee.

11 November 2016
Verified
Conference Paper
Closed access
PDF file
MBMario G. Bernal-Torres
Mario G. Bernal-Torres
HMHugo Medellin-Castillo
Hugo Medellin-Castillo
JAJuan C. Arellano-González
Juan C. Arellano-González
Commercial available knee prostheses are still limited because most of them comprise passive elements that store and deliver energy during the gait cycle, but without providing additional energy. This inability to provide additional energy affects the performance of passive prostheses, which in some cases demands up to 60% of additional metabolic energy to perform a gait cycle. Recent research works have focused on the design of active knee prostheses, including the development and implementation of control strategies such as electromyographic (EMG) signals. However, the results of such implementations reveal that these control strategies are still limited because of the relatively long time response and inaccurate movements. This paper presents the design of a new biomimetic-controlled knee prosthesis for transfemoral amputation. The aim is to contribute to the development of simple and effective active knee prostheses. The proposed prosthesis consists of a polycentric mechanism obtained from the body-guidance kinematics synthesis of a four bar linkage. This synthesis is based on the natural movements of the human knee, taking into account the shortening effect of the leg during the walking process to avoid trips. The prosthetic knee mimics the human motion of the healthy leg by means of an echo-control strategy. An experimental prototype has been implemented and tested on a workbench. The experimental results have demonstrated the usability of the proposed biomimetic active knee prosthesis.