Carlos Alberto Lima Utrabo

Carlos Alberto Lima Utrabo

Auto-generated profile, based on publicly available information

Carlos Alberto Lima Utrabo

State University of Ponta Grossa, Brazil

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2021 in ABCD. Arquivos Brasileiros de Cirurgia Digestiva (São Paulo)
Verified
Journal Article
Open access
CUCarlos Alberto Lima Utrabo
Carlos Alberto Lima Utrabo
NCNicolau Gregori Czeczko
Nicolau Gregori Czeczko
CBCesar Roberto Busato
Cesar Roberto Busato
MMMário Rodrigues Montemór-Netto
Mário Rodrigues Montemór-Netto
LLLeandro Lipinski
Leandro Lipinski
OMOsvaldo Malafaia
Osvaldo Malafaia
Background: In the definition of the mesh to be used to correct hernias, porosity, amount of absorbable material and polypropylene should be considered in the different stages of healing process. Aim: To evaluate the inflammatory reaction in the use of macro and microporous meshes of high and low weight in the repair of defects in the abdominal wall of rats. Methods: Ninety Wistar rats (Rattus norvegicus albinus) were used. The animals were submitted to similar surgical procedures, with lesion of the ventral abdominal wall, maintaining the integrity of the parietal peritoneum and correction using the studied meshes (Prolene®, Ultrapro® and Bard Soft®). Euthanasia was performed at 30, 60 and 120 days after surgery. The abdominal wall segments were submitted to histological analysis using H&E, Masson’s trichrome, immunohistochemistry, picrosirius red and tensiometric evaluation. Results: On the 120th day, the tensiometric analysis was superior with Ultrapro® macroporous mesh. The inflammatory process score showed a significant prevalence of subacute process at the beginning and at the end of the study. Microporous meshes showed block encapsulation and in macroporous predominance of filamentous encapsulation. Conclusion: The Ultrapro® mesh showed better performance than the others in healing process of the abdominal wall.

1 April 2012 in Acta Cirurgica Brasileira
Verified
Journal Article
Open access
PDF file
CUCarlos Alberto Lima Utrabo
Carlos Alberto Lima Utrabo
NCNicolau Gregori Czeczko
Nicolau Gregori Czeczko
CBCesar Roberto Busato
Cesar Roberto Busato
MMMario Rodrigues Montemor-Netto
Mario Rodrigues Montemor-Netto
OMOsvaldo Malafaia
Osvaldo Malafaia
UDUlrich Andreas Dietz
Ulrich Andreas Dietz
To evaluate the healing process of a defect in the ventral abdominal wall of rats, comparing the polypropylene and polypropylene/poliglecaprone meshes on the 30(th) and 60(th) postoperative day.

1 September 2017 in ABCD. Arquivos Brasileiros de Cirurgia Digestiva (São Paulo)
Verified
Journal Article
Open access
CUCarlos Alberto Lima Utrabo
Carlos Alberto Lima Utrabo
NCNicolau Gregori Czeczko
Nicolau Gregori Czeczko
CBCesar Roberto Busato
Cesar Roberto Busato
MMMário Rodrigues Montemór-Netto
Mário Rodrigues Montemór-Netto
LLLeandro Lipinski
Leandro Lipinski
OMOsvaldo Malafaia
Osvaldo Malafaia
Background: Among the various strategies to avoid exaggerated foreign body reaction in the treatment of hernias is the limitation of the amount of polypropylene or the use of absorbable material. Aim: To evaluate the healing of defects in the abdominal wall of rats, comparing microporous polypropylene, macroporous polypropylene and polypropylene/polyglecaprone at the 30º, 60º and 120º postoperative day. Methods: Wistar rats were submitted to defect production in the ventral abdominal wall, with integrity of the parietal peritoneum. Prolene®, Ultrapro® and Bard Soft® meshes were used in the correction of the defect. Nine subgroups of 10 animals were submitted to euthanasia at 30th, 60th and 120th postoperative day. Fragments of the abdominal wall of the animals were submitted to tensiometric analysis. Results: The tensiometry at the 30th postoperative day showed greater resistance of the tissues with Bard Soft® (macroporous mesh) in relation to the tissues with Prolene® (microporous mesh). On the 60th postoperative day Bard Soft® maintained the superior resistance to the tissues comparing to Prolene Mesh®. On the 120th postoperative day the tissues repaired with Ultrapro® (macroporous mesh) proved to be more resistant than the ones by Prolene® (microporous mesh) and Bard Soft® (macroporous mesh). Conclusion: The tissues repaired with macroporous meshes showed greater resistance than with microporous meshes at all stages, and at 120 days postoperative Ultrapro® performed better than the others.

1 January 2022 in ABCD. Arquivos Brasileiros de Cirurgia Digestiva (São Paulo)
Verified
Journal Article
Open access
CUCarlos Alberto Lima Utrabo
Carlos Alberto Lima Utrabo
CBCesar Roberto Busato
Cesar Roberto Busato
MMMário Rodrigues Montemór-Netto
Mário Rodrigues Montemór-Netto
LLLeandro Cavalcanti Lipinski
Leandro Cavalcanti Lipinski
VCVitória Rossetim Celinski
Vitória Rossetim Celinski
KKKoga Yuriko Koga
Koga Yuriko Koga
- BACKGROUND: Proper fixation of the surgical mesh determines the success of a herniorrhaphy. Understanding the inflammatory response and the mechanical properties of the mesh helps to define whether a fixation method is superior. AIM: This study aimed to evaluate the healing of defects in the abdominal wall of rats, comparing the repair of macroporous polypropylene meshes fixed with surgical glue and polypropylene thread. METHODS: In 20 Wistar rats, a defect was produced in the abdominal wall, with the integrity of the parietal peritoneum. For correction, the meshes were fixed with surgical glue (2-octyl cyanoacrylate) (subgroup C1), or polypropylene suture (subgroup C2). The two subgroups of 10 animals were euthanized on the 90th postoperative day, and the fragments of the abdominal wall were submitted to macroscopic, histological, and tensiometric analysis. RESULTS: Macroscopic analysis did not show any abnormalities. Tensiometry on the 90th postoperative day in subgroup C1 showed mean rupture tension of 28.47N and in subgroup C2 32.06N (p=0.773). The inflammatory process score revealed that both groups are in the subacute phase (p=0.380). CONCLUSION: The fixation of a polypropylene macroporous mesh to repair an abdominal wall defect can be performed with surgical glue (2-octyl cyanoacrylate) or polypropylene suture, both methods being equally effective.

Verified
Journal Article
Open access
CUCarlos Alberto Lima Utrabo
Carlos Alberto Lima Utrabo
CBCesar Roberto Busato
Cesar Roberto Busato
KKKoga Yuriko Koga
Koga Yuriko Koga
JMJanete Machozeki
Janete Machozeki
MGMirian Guimarães
Mirian Guimarães
LLLeandro Cavalcante Lipinski
Leandro Cavalcante Lipinski
Adequate closure of the abdominal wall determines the success of the surgery. The aim of this study was to study the healing of the abdominal wall of rats by comparing the use of surgical glue (2-octyl cyanoacrylate) with polypropylene 3.0 thread and poliglecaprone 3.0 thread. A total of 60 Wistar rats were divided into two groups: Group 30 and Group 90. Each group was subdivided into three subgroups, surgical glue subgroup (C1), polypropylene subgroup (C2), and poliglecaprone subgroup (C3). An incision was made in the aponeurosis of the abdominal wall while maintaining the integrity of the parietal peritoneum. The 3 subgroups of 10 animals were euthanized on the 30th and 90th postoperative days. The abdominal wall fragments were submitted to macroscopic, histological, and tensiometric analysis. Macroscopic analysis did not show any abnormality. Tensiometry on the 30th postoperative day showed a mean rupture tension of 30.98N in subgroup C1, 27.90N in subgroup C2, and 23.90N in subgroup C3. On the 90th postoperative day, the mean rupture tension was 30.05N in subgroup C1, 44.42N in subgroup C2, and 34.78N in subgroup C3. The synthesis of the abdominal aponeurosis performed with surgical glue (2-octyl cyanoacrylate) showed adequate resistance to rupture tension to maintain its integrity when compared with the synthesis with polypropylene thread or poliglecaprone thread, with both methods being equally effective.