Hee Jeong Son

Hee Jeong Son

Auto-generated profile, based on publicly available information

Hee Jeong Son

Department of Anesthesiology and Pain Medicine, Kangwon National University Hospital, Kangwon National University School of Medicine, Chuncheon, Korea

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 January 2022 in Anesthesia and Pain Medicine
Verified
Journal Article
Open access
PDF file
JBJi Won Bak
Ji Won Bak
YNYeonji Noh
Yeonji Noh
JKJuyoun Kim
Juyoun Kim
BHByeongmun Hwang
Byeongmun Hwang
SKSeongsik Kang
Seongsik Kang
MKMinsoo Kim
Minsoo Kim
Background: The GlideScope® videolaryngoscope (GVL) is widely used in patients with difficult airways and provides a good glottic view. However, the acute angle of the blade can make insertion and advancement of an endotracheal tube (ETT) more difficult than direct laryngoscopy, and the use of a stylet is recommended. This randomized controlled trial compared Parker Flex-It™ stylet (PFS) with GlideRite® rigid stylet (GRS) to facilitate intubation with the GVL in simulated difficult intubations. Methods: Fifty-four patients were randomly allocated to undergo GVL intubation using either GRS (GRS group) or PFS (PFS group). The total intubation time (TIT), 100-mm visual analog scale (VAS) for ease of intubation, success rate at the first attempt, use of laryngeal manipulation, tube advancement rate by assistant, and complications were recorded. Results: There was no significant difference between the GRS and PFS groups regarding TIT (50.3 ± 12.0 s in the GRS group and 57.8 ± 18.8 s in the PFS group, P = 0.108). However, intubation was more difficult in the PFS group than in the GRS group according to VAS score (P = 0.011). Cases in which the ETT was advanced from the stylet by an assistant, were more frequent in the GRS group than in the PFS group (P = 0.002). The overall incidence of possible complications was not significantly different. Conclusions: In patients with a simulated difficult airway, there was no difference in TIT using either the PFS or GRS. However, endotracheal intubation with PFS is more difficult to perform than GRS.

1 January 2022 in Journal of Korean Medical Science
Verified
Journal Article
Open access
PDF file
SKSeok Hoon Kang
Seok Hoon Kang
TKTae Hyun Kim
Tae Hyun Kim
HSHee Jeong Son
Hee Jeong Son
YPYOUNGJIN PARK
YOUNGJIN PARK
SLSeunghee Lee
Seunghee Lee
Kang SH, et al. J Korean Med Sci. 2022 May;37(20):e163. https://doi.org/10.3346/jkms.2022.37.e163