Hasballah Zakaria

Hasballah Zakaria

Auto-generated profile, based on publicly available information

Hasballah Zakaria

Institut Teknologi Bandung

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 February 2023 in Sensors
Verified
Journal Article
Open access
PDF file
SHSugondo Hadiyoso
Sugondo Hadiyoso
HZHasballah Zakaria
Hasballah Zakaria
POPaulus Anam Ong
Paulus Anam Ong
TRTati Latifah Erawati Rajab
Tati Latifah Erawati Rajab
Dementia is a term that represents a set of symptoms that affect the ability of the brain’s cognitive functions related to memory, thinking, behavior, and language. At worst, dementia is often called a major neurocognitive disorder or senile disease. One of the most common types of dementia after Alzheimer’s is vascular dementia. Vascular dementia is closely related to cerebrovascular disease, one of which is stroke. Post-stroke patients with recurrent onset have the potential to develop dementia. An accurate diagnosis is needed for proper therapy management to ensure the patient’s quality of life and prevent it from worsening. The gold standard diagnostic of vascular dementia is complex, includes psychological tests, complete memory tests, and is evidenced by medical imaging of brain lesions. However, brain imaging methods such as CT-Scan, PET-Scan, and MRI have high costs and cannot be routinely used in a short period. For more than two decades, electroencephalogram signal analysis has been an alternative in assisting the diagnosis of brain diseases associated with cognitive decline. Traditional EEG analysis performs visual observations of signals, including rhythm, power, and spikes. Of course, it requires a clinician expert, time consumption, and high costs. Therefore, a quantitative EEG method for identifying vascular dementia in post-stroke patients is discussed in this study. This study used 19 EEG channels recorded from normal elderly, post-stroke with mild cognitive impairment, and post-stroke with dementia. The QEEG method used for feature extraction includes relative power, coherence, and signal complexity; the evaluation performance of normal-mild cognitive impairment-dementia classification was conducted using Support Vector Machine and K-Nearest Neighbor. The results of the classification simulation showed the highest accuracy of 96% by Gaussian SVM with a sensitivity and specificity of 95.6% and 97.9%, respectively. This study is expected to be an additional criterion in the diagnosis of dementia, especially in post-stroke patients.

19 November 2022 in Journal of Healthcare Engineering
Verified
Journal Article
Open access
PDF file
SHSugondo Hadiyoso
Sugondo Hadiyoso
POPaulus Anam - Ong
Paulus Anam - Ong
HZHasballah Zakaria
Hasballah Zakaria
TRTati Latifah E. Rajab
Tati Latifah E. Rajab
One common type of vascular dementia (VaD) is poststroke dementia (PSD). Vascular dementia can occur in one-third of stroke patients. The worsening of cognitive function can occur quickly if not detected and treated early. One of the potential medical modalities for observing this disorder by considering costs and safety factors is electroencephalogram (EEG). It is thought that there are differences in the spectral dynamics of the EEG signal between the normal group and stroke patients with cognitive impairment so that it can be used in detection. Therefore, this study proposes an EEG signal characterization method using EEG spectral power complexity measurements to obtain features of poststroke patients with cognitive impairment and normal subjects. Working memory EEGs were collected and analyzed from forty-two participants, consisting of sixteen normal subjects, fifteen poststroke patients with mild cognitive impairment, and eleven poststroke patients with dementia. From the analysis results, it was found that there were differences in the dynamics of the power spectral in each group, where the spectral power of the cognitively impaired group was more regular than the normal group. Notably, (1) significant differences in spectral entropy (SpecEn) with a value <0.05 were found for all electrodes, (2) there was a relationship between SpecEn values and the severity of dementia (SpecEnDem < SpecEnMCI < SpecEnNormal), and (3) a post hoc multiple comparison test showed significant differences between groups at the F7 electrode. This study shows that spectral complexity analysis can discriminate between normal and poststroke patients with cognitive impairment. For further studies, it is necessary to simulate performance validation so that the proposed approach can be used in the early detection of poststroke dementia and monitoring the development of dementia.

1 July 2019
Verified
Conference Paper
Closed access
EDErvin Masita Dewi
Ervin Masita Dewi
TMTati Latifah Rajab Mengko
Tati Latifah Rajab Mengko
HZHasballah Zakaria
Hasballah Zakaria
KAKastam Astami
Kastam Astami
Atherosclerosis is a condition indicated by loss of arterial elasticity because of thickening of the arterial wall due to plaques that cause cardiovascular disease. Increased arterial stiffness is one sign of atherosclerosis, so measurement of arterial stiffness can be used as an early detection of cardiovascular disease. One method of measuring arterial stiffness is by analyzing the second derivative of a photoplethysmography (PPG) signal taken from a non-invasive fingertip. PPG signals are obtained from infra red signal transmission to detect changes in blood volume in microvascular vessels. By calculating the delay between direct waves and reflection waves from PPG signals and also from taking the subject's height can be obtained arterial stiffness index. PPG data collection was carried out on 30 subjects, with 10 subjects normal and 10 subjects were cardiac catheterization patients and 10 subjects were athlete. The stiffness index value for cardiac catheterization patients increased compared to athlete and normal subjects. Increased arterial stiffness is one sign of atherosclerosis, so measurement of arterial stiffness can be used as an early detection of cardiovascular disease.

1 August 2017
Verified
Conference Paper
Closed access
HZHasballah Zakaria
Hasballah Zakaria
PHPatonah Hasimun
Patonah Hasimun
Atherosclerosis, hardening of the arteries, causes heart attacks and strokes that are recorded as the world's number one killer disease. Nowadays, research on atherosclerosis is still limited because the modeling of atherosclerotic animals is difficult to do. Pulse wave velocity (PWV) is used clinically as a measure of arterial stiffness. PWV measurements in animals can be done invasively and non-invasively. PWV values have a strong correlation with cardiovascular conditions. This study aimed to create a PWV measuring instrument in mice to estimate the occurrence of atherosclerosis. The device developed will be highly beneficial in enhancing the research and development of anti-atherosclerotic drugs. PWV measurement was performed non-invasively by using electrocardiogram (ECG) and photoplethysmogram (PPG) sensors. The ECG electrode was placed on the left and right front legs and right rear leg of the test animal. While the PPG sensor placed on the rat tail. PWV is the traveling speed along the arterial segment from the heart position point to the PPG sensor position at the base of the tail. By comparing the EKG and PPG waveforms the amount of travel time (Pulse transit time, PTT) can be determined. The measurement results were obtained in less than a minute. The average PWV measurement results with the proposed method in normal mice aged one to three months was 480 cm/s, within the range of the results obtained by existing standard methods.

1 July 2019
Verified
Conference Paper
Closed access
DSDaniel Steven Doxazo Sitompul
Daniel Steven Doxazo Sitompul
FSFakhri Pradana Suhandi
Fakhri Pradana Suhandi
HZHasballah Zakaria
Hasballah Zakaria
Runway edge light is a runway lighting indicator which provides guidance to pilots on nightfall or bad weather, thereby a regular intensity measurement is required to ensure safety of flights in airport based on aviation regulation. Most instruments that are currently available used ground vehicle to conduct photometry which has a high dependence on airport infrastructure conditions. This paper proposed a new photometric method using an instrument carried by a drone thus lowering its dependency on airport infrastructures conditions. The instrument utilized a photodiode array consisting of an aluminum bar with several photodiode module sensors separated apart with the same distance. To prove the concept the instrument was used to measure a Thorn EL-EAH runway edge light in laboratory setting at Balai Teknik Penerbangan Indonesia (Indonesia Aviation Engineering Center). The vertical scanning method was used to obtain the required measurement points. Computer program was then used to generate the isocandela diagram through the Kriging interpolation. Results showed that the vertical scanning method was successfully measure all required points and the resulted isocandela diagram was adequate to aviation regulation.

1 January 2021 in Journal Of Biochemical Technology
Verified
Journal Article
Open access
PHPatonah Hasimun
Patonah Hasimun
YMYani Mulyani
Yani Mulyani
HZHasballah Zakaria
Hasballah Zakaria
ASAdinda Rizkia Setiawan
Adinda Rizkia Setiawan
Centella asiatica (CA) has been reported to have a protective effect on cardiovascular disease and cardiovascular disease-related conditions. Frontal QRS-T angle is a non-invasive biomarker that can predict cardiovascular mortality and morbidity in all causes of death. This study aimed to establish the protective effect of CA in animal models of me