Deland Hu Liu

Deland Hu Liu

Auto-generated profile, based on publicly available information

Deland Hu Liu

Chandra Family Department of Electrical and Computer Engineering, The University of Texas at Austin, 301 E. Dean Keeton St. C2100, Austin, Texas, 78712-1139, UNITED STATES

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 September 2020 in IEEE Access
Verified
Journal Article
Open access
DLDeland Hu Liu
Deland Hu Liu
Syed Anas ImtiazSyed Anas Imtiaz
Syed Anas Imtiaz
Long-term sleep monitoring through the use of wearable EEG-based systems generates large volumes of data that need to be either locally stored or wireless transmitted. Compression of data can play a vital role to reduce the power consumption of these already resource-constrained systems. While compression methods can result in significantly reduced data storage and transmission requirements, the loss in signal information can have an impact on the algorithms used to extract the key sleep parameters. This paper studies the impact of six different state-of-the-art compression methods, including wavelet, SPIHT, filter and predictor-based methods, analysing their effects on the reconstructed signal quality particularly for automatic sleep staging applications. It looks at how the overall sleep staging accuracy as well as the detection accuracy of different sleep stages is reduced as a result of different EEG compression methods. It shows that the SPIHT and predictor-based compression methods outperform wavelet and filter-based methods in preserving the relevant signal features. It also shows that compression ratios of up to 65 can be achieved using the QSPIHT method with less than 10% loss in overall sleep staging accuracy.

7 January 2025 in Journal of Neural Engineering
Verified
Journal Article
Open access
DLDeland H Liu
Deland H Liu
JHJu-Chun Hsieh
Ju-Chun Hsieh
HAHussein Alawieh
Hussein Alawieh
SKSatyam Kumar
Satyam Kumar
FIFumiaki Iwane
Fumiaki Iwane
JMJosé del R. Millán
José del R. Millán
Objective. Non-invasive electroencephalograms (EEG)-based brain–computer interfaces (BCIs) play a crucial role in a diverse range of applications, including motor rehabilitation, assistive and communication technologies, holding potential promise to benefit users across various clinical spectrums. Effective integration of these applications into daily life requires systems that provide stable and reliable BCI control for extended periods. Our prior research introduced the AIRTrode, a self-adhesive (A), injectable (I), and room-temperature (RT) spontaneously-crosslinked hydrogel electrode (AIRTrode). The AIRTrode has shown lower skin-contact impedance and greater stability than dry electrodes and, unlike wet gel electrodes, does not dry out after just a few hours, enhancing its suitability for long-term application. This study aims to demonstrate the efficacy of AIRTrodes in facilitating reliable, stable and long-term online EEG-based BCI operations. Approach. In this study, four healthy participants utilized AIRTrodes in two BCI control tasks–continuous and discrete–across two sessions separated by six hours. Throughout this duration, the AIRTrodes remained attached to the participants’ heads. In the continuous task, participants controlled the BCI through decoding of upper-limb motor imagery (MI). In the discrete task, the control was based on decoding of error-related potentials (ErrPs). Main Results. Using AIRTrodes, participants demonstrated consistently reliable online BCI performance across both sessions and tasks. The physiological signals captured during MI and ErrPs tasks were valid and remained stable over sessions. Lastly, both the BCI performances and physiological signals captured were comparable with those from freshly applied, research-grade wet gel electrodes, the latter requiring inconvenient re-application at the start of the second session. Significance. AIRTrodes show great potential promise for integrating non-invasive BCIs into everyday settings due to their ability to support consistent BCI performances over extended periods. This technology could significantly enhance the usability of BCIs in real-world applications, facilitating continuous, all-day functionality that was previously challenging with existing electrode technologies.

1 February 2025 in Journal of Neural Engineering
Verified
Journal Article
Open access
DLDeland H Liu
Deland H Liu
SKSatyam Kumar
Satyam Kumar
HAHussein Alawieh
Hussein Alawieh
FRFrigyes Samuel Racz
Frigyes Samuel Racz
JMJosé del R. Millán
José del R. Millán
Objective. A motor imagery (MI)-based brain–computer interface (BCI) enables users to engage with external environments by capturing and decoding electroencephalography (EEG) signals associated with the imagined movement of specific limbs. Despite significant advancements in BCI technologies over the past 40 years, a notable challenge remains: many users lack BCI proficiency, unable to produce sufficiently distinct and reliable MI brain patterns, hence leading to low classification rates in their BCIs. The objective of this study is to enhance the online performance of MI-BCIs in a personalized, biomarker-driven approach using transcranial alternating current stimulation (tACS). Approach. Previous studies have identified that the peak power spectral density value in sensorimotor idling rhythms is a neural correlate of participants’ upper limb MI-BCI performances. In this active-controlled, single-blind study, we applied 20 min of tACS at the participant-specific, peak µ frequency in resting-state sensorimotor rhythms (SMRs), with the goal of enhancing resting-state µ SMRs. Main results. After tACS, we observed significant improvements in event-related desynchronizations (ERDs) of µ SMRs, and in the performance of an online MI-BCI that decodes left versus right hand commands in healthy participants (N = 10)—but not in an active control-stimulation control group (N = 10). Lastly, we showed a significant correlation between the resting-state µ SMRs and µ ERD, offering a mechanistic interpretation behind the observed changes in online BCI performances. Significance. Our research lays the groundwork for future non-invasive interventions designed to enhance BCI performances, thereby improving the independence and interactions of individuals who rely on these systems.

13 January 2025 in Journal of Neural Engineering
Verified
Journal Article
Open access
DLDeland Hu Liu
Deland Hu Liu
SKSatyam Kumar
Satyam Kumar
HAHussein Alawieh
Hussein Alawieh
FRFrigyes Samuel Racz
Frigyes Samuel Racz
JMJosé del R. Millán
José del R. Millán
Objective. A motor imagery (MI)-based brain-computer interface (BCI) enables users to engage with external environments by capturing and decoding electroencephalography (EEG) signals associated with the imagined movement of specific limbs. Despite significant advancements in BCI technologies over the past 40 years, a notable challenge remains: many users lack BCI proficiency, unable to produce sufficiently distinct and reliable MI brain patterns, hence leading to low classification rates in their BCIs. The objective of this study is to enhance the online performance of MI-BCIs in a personalized, biomarker-driven approach using transcranial alternating current stimulation (tACS). Approach. Previous studies have identified that the peak power spectral density (PSD) value in sensorimotor idling rhythms is a neural correlate of participants’ upper limb MI-BCI performances. In this active-controlled, single-blind study, we applied 20 minutes of tACS at the participant-specific, peak µ frequency in resting-state sensorimotor rhythms (SMRs), with the goal of enhancing resting-state µ SMRs. Main Results. After tACS, we observed significant improvements in event-related desynchronizations (ERDs) of µ sensorimotor rhythms (SMRs), and in the performance of an online MI-BCI that decodes left versus right hand commands in healthy participants (N=10) —but not in an active control-stimulation control group (N=10). Lastly, we showed a significant correlation between the resting-state µ SMRs and µ ERD, offering a mechanistic interpretation behind the observed changes in online BCI performances. Significance. Our research lays the groundwork for future non-invasive interventions designed to enhance BCI performances, thereby improving the independence and interactions of individuals who rely on these systems.

19 November 2025 in IEEE Robotics and Automation Letters
Verified
Journal Article
Closed access
SKSatyam Kumar
Satyam Kumar
KMKanishka Mitra
Kanishka Mitra
DLDeland H. Liu
Deland H. Liu
HAHussein Alawieh
Hussein Alawieh
FRFrigyes Samuel Racz
Frigyes Samuel Racz
JMJosé del R. Millán
José del R. Millán
Robot-assisted therapy has long promised to advance stroke rehabilitation by delivering intensive and personalized training, yet its clinical impact remains limited. Closing the sensorimotor loop with brain–computer interfaces offers a better strategy than passive mobilization, directly linking user intent to robotic assistance and potentially driving neuroplasticity. However, a brain-computer interface requires subject-specific calibration that is time-consuming and often impractical. Moreover, brain decoding remains error-prone due to variability of neural signals, thus resulting in unintended robot actions that could reduce engagement during closed-loop control. Here, we demonstrate that a decoder trained on an expert subject can be transferred to naïve users for online control of a rehabilitation exoskeleton in a rest-versus-reaching paradigm, a functional task with clinical relevance. We then characterize error-related potentials arising from expectation mismatches between brain commands and robot actions during closed-loop control. Finally, we show that these mismatches can be reliably decoded in a subject-independent framework (mean area under the receiver operating characteristic curve: 0.77), a crucial step toward rehabilitation scenarios where collecting subject-specific error-related potential data is challenging. Our findings highlight the potential for integrating real-time error-detection to enhance human–robot interaction by correcting unintended robot behaviors, which could significantly improve rehabilitation outcomes where accurate and contingent feedback is essential.

15 July 2026 in Advanced Science
Verified
Journal Article
Open access
PDF file
DLDeland H. Liu
Deland H. Liu
FIFumiaki Iwane
Fumiaki Iwane
MZMinsu Zhang
Minsu Zhang
LCLeonardo G. Cohen
Leonardo G. Cohen
JMJosé del R. Millán
José del R. Millán
Accurate perception of subtle visuo‐motor errors is essential for perceptual and sensorimotor learning, and supports timely corrective actions in precision‐based task. However, conventional perceptual training, typically based on response‐accuracy feedback, is limited in improving sensitivity to small, subtle errors. While prior approaches have focused on modulating sensory regions to enhance perceptual learning, we propose an alternative approach that targets a cognitive neural marker: the error positivity (Pe), a component of the error‐related potential (ErrP) originating in the anterior cingulate cortex, a key decision‐making region. We hypothesize that the Pe, which reflects conscious awareness of errors, serves as a modifiable neural correlate of error perception. In a five‐day longitudinal study, we show that providing real‐time feedback on the presence or absence of ErrPs during perceptual training accelerates perceptual learning at errors and enhances perceptual performance at errors without accelerating the learning rate, relative to behavioral training alone. These behavioral gains were accompanied by increase in Pe amplitude. Together, these findings offer new neurophysiological insights into the mechanisms of error perception, and establish ErrP‐based brain‐computer interface interventions as a promising approach for fostering perceptual learning in domains where detecting subtle errors is critical.