Interior permanent magnet synchronous motor (IPMSM) with back electromotive-force (EMF) based sensorless field-oriented control (FOC) is widely used in medium-high speed applications. Unfortunately, the back EMF is too small to be estimated accurately during low speed operation. Hence, the current-frequency ( I–f ) control with controllable current vector is used for startup. However, the conventional I–f control is hard to realize the tradeoff between startup speed and load capacity, suffering high-acceleration and high-load startup failure. In this article, a current vector angle controller for sensorless IPMSM startup is proposed to adjust speed-up-stage current acceleration and constant-speed-stage current amplitude with load automatically. The proposed angle controller guarantees the current vector angle close to the maximum torque per ampere angle, which contributes to large startup torque, high operating efficiency and smooth transition from I–f startup to sensorless FOC. Furthermore, the robustness against parameters variation of angle controller is evaluated quantitatively. These theoretical advantages are verified in experiments with a 380 V, 1.5 kW IPMSM. In particular, the experimental results demonstrate that the proposed I–f control realizes full-load startup even with ${\rm{ \pm }}$ 50% flux linkage and ${\rm{ \pm }}$ 30% inductance variation. Furthermore, the startup acceleration auto-adjusts with load to reconcile startup speed and load capacity.
1 February 2007 in APEC 07 - Twenty-Second Annual IEEE Applied Power Electronics Conference and Exposition
In the past 14 years, several patented 18-pulse converter methods have been accepted in the marketplace and successfully applied in various practical applications. In this paper, a widely used 18-pulse clean power converter, with "windmill" transformer topology is presented and analyzed. It provides a more economical solution to achieve harmonic mitigation in electric power systems as compared to some of the earlier methods. A complete adjustable speed drive (ASD) system model including "windmill" transformer, 9-phase diode bridge, DC link capacitors, inverter with SVPWM (space vector pulse width modulation), and induction machine, has been modeled and built for analysis. Features addressed are, input current harmonic mitigation, DC bus capacitor ripple current and lifespan, and motor ripple torque. In addition, the DC link dynamics under a motor step load change, as well as input voltage unbalance effects on the 18-pulse converter have been evaluated. Quantification of many of these issues is not found in present literature. Experimental tests with a 75 hp "windmill" 18-pulse clean power ASD system, verify the accuracy and effectiveness of the analysis.
In this paper, a high performance dc link current observer is described and analyzed for a double conversion uninterruptible power system (UPS) or an adjustable speed drive (ASD). This second order observer identifies the dc link current drawn by the output inverter section. The observed load current is then used as a feedforward signal to input converter current regulator section for improving its dynamic response. The new contributions include the analysis on the system observability, observer sensitivity to system parameters, its command tracking performance, dc link voltage and load current dynamic disturbance rejection capabilities, all of which are not found in present literatures. In conjunction with the dc link current observer analysis, the current regulator bandwidth performance of the input ac-dc converter stage is characterized for both single and double update pulse width modulation (PWM) methods. The high performance resides in its fast dynamic response to the load power requirements resulting in dc link voltage variation, without using dc link current sensor or any communication channels. The solution is not only ideal for a stand alone UPS or ASD for low cost and high dynamic performance, but is particularly attractive for ac-dc converters suitable for common dc link systems. The analytical results are verified through the state-of-the-art simulation. All control algorithms are implemented in a Texas Instruments (TI) digital signal processor (DSP) and Xilinx field programmable gate array (FPGA) environment. The experimental setup of a 3- phase, 480V, 60Hz, 15 hp (11.
In this paper, computationally-efficient sinusoidal disturbance estimation and elimination methods are introduced into the control of an active front end (AFE) voltage-source converter (VSC) to achieve effective disturbance rejection in high-power systems with slower PWM switching frequencies (e.g., 5 kHz) and limited current controller bandwidth. Since the active rectifier is in series with the source and the load, there is no need to add additional hardware for harmonic elimination. The input positive- and negative-sequence voltages are extracted using the new observer methods and negative-sequence currents are injected to eliminate the dc link 120 Hz ripple. The observer-based disturbance rejection methods are proven to be very effective when all three types of disturbances (input voltage harmonics, unbalance, and inductor unbalance) co-exist simultaneously, even under input inductance variations of 30%. Simulation results are verified experimentally using a 15 hp adjustable-speed drive (ASD) system that includes an AFE-VSC coupled to a dSpace controller.
19 March 2026 in IEEE Transactions on Industry Applications
This Guest Editorial introduces the Special Issue on Advanced Design and Control of High-Speed Motors. High-speed electric machines and their drives are enabling key applications including electrified transportation, aerospace, turbocompressors, and high-power-density industrial systems, while imposing stringent constraints on electromagnetic performance, rotor mechanical integrity, thermal management, and converter–control co-design. Following the review process, 33 papers were selected for publication. Highlights of each paper and their main contributions are discussed.