Fabian F. Voigt

Fabian F. Voigt

Auto-generated profile, based on publicly available information

Fabian F. Voigt

Brain Research Institute, University of Zurich, Winterthurerstrasse 190, 8057 Zurich, Switzerland

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 September 2019 in Nature Methods
Verified
Journal Article
Closed access
PDF file
FVFabian F. Voigt
Fabian F. Voigt
DKDaniel Kirschenbaum
Daniel Kirschenbaum
EPEvgenia Platonova
Evgenia Platonova
SPStéphane Pagès
Stéphane Pagès
RCRobert A. A. Campbell
Robert A. A. Campbell
FHFritjof Helmchen
Fritjof Helmchen

30 August 2013 in Optics Express
Verified
Journal Article
Closed access
PDF file
FFFlorian O. Fahrbach
Florian O. Fahrbach
FVFabian F. Voigt
Fabian F. Voigt
BSBenjamin Schmid
Benjamin Schmid
FHFritjof Helmchen
Fritjof Helmchen
JHJan Huisken
Jan Huisken
Optics InfoBase is the Optical Society's online library for flagship journals, partnered and copublished journals, and recent proceedings from OSA conferences.

23 June 2011 in Biomedical Optics Express
Verified
Journal Article
Open access
PDF file
BGBenjamin F. Grewe
Benjamin F. Grewe
FVFabian F. Voigt
Fabian F. Voigt
MHMarcel van ’t Hoff
Marcel van ’t Hoff
FHFritjof Helmchen
Fritjof Helmchen
Functional two-photon Ca2+-imaging is a versatile tool to study the dynamics of neuronal populations in brain slices and living animals. However, population imaging is typically restricted to a single two-dimensional image plane. By introducing an electrically tunable lens into the excitation path of a two-photon microscope we were able to realize fast axial focus shifts within 15 ms. The maximum axial scan range was 0.7 mm employing a 40x NA0.8 water immersion objective, plenty for typically required ranges of 0.2–0.3 mm. By combining the axial scanning method with 2D acousto-optic frame scanning and random-access scanning, we measured neuronal population activity of about 40 neurons across two imaging planes separated by 40 μm and achieved scan rates up to 20–30 Hz. The method presented is easily applicable and allows upgrading of existing two-photon microscopes for fast 3D scanning.

3 September 2020 in Nature
Verified
Journal Article
Closed access
PDF file
ABAbhishek Banerjee
Abhishek Banerjee
GPGiuseppe Parente
Giuseppe Parente
JTJasper Teutsch
Jasper Teutsch
CLChristopher Lewis
Christopher Lewis
FVFabian F. Voigt
Fabian F. Voigt
FHFritjof Helmchen
Fritjof Helmchen

24 May 2016 in eLife
Verified
Journal Article
Open access
JCJerry L Chen
Jerry L Chen
FVFabian F Voigt
Fabian F Voigt
MJMitra Javadzadeh
Mitra Javadzadeh
RKRoland Krueppel
Roland Krueppel
FHFritjof Helmchen
Fritjof Helmchen
The coordination of activity across neocortical areas is essential for mammalian brain function. Understanding this process requires simultaneous functional measurements across the cortex. In order to dissociate direct cortico-cortical interactions from other sources of neuronal correlations, it is furthermore desirable to target cross-areal recordings to neuronal subpopulations that anatomically project between areas. Here, we combined anatomical tracers with a novel multi-area two-photon microscope to perform simultaneous calcium imaging across mouse primary (S1) and secondary (S2) somatosensory whisker cortex during texture discrimination behavior, specifically identifying feedforward and feedback neurons. We find that coordination of S1-S2 activity increases during motor behaviors such as goal-directed whisking and licking. This effect was not specific to identified feedforward and feedback neurons. However, these mutually projecting neurons especially participated in inter-areal coordination when motor behavior was paired with whisker-texture touches, suggesting that direct S1-S2 interactions are sensory-dependent. Our results demonstrate specific functional coordination of anatomically-identified projection neurons across sensory cortices.

3 November 2017 in IEEE Transactions on Biomedical Circuits and Systems
Verified
Journal Article
Open access
DMDiederik Paul Moeys
Diederik Paul Moeys
FCFederico Corradi
Federico Corradi
CLChenghan Li
Chenghan Li
SBSimeon A. Bamford
Simeon A. Bamford
LLLuca Longinotti
Luca Longinotti
TDTobi Delbruck
Tobi Delbruck
Applications requiring detection of small visual contrast require high sensitivity. Event cameras can provide higher dynamic range (DR) and reduce data rate and latency, but most existing event cameras have limited sensitivity. This paper presents the results of a 180-nm Towerjazz CIS process vision sensor called SDAVIS192. It outputs temporal contrast dynamic vision sensor (DVS) events and conventional active pixel sensor frames. The SDAVIS192 improves on previous DAVIS sensors with higher sensitivity for temporal contrast. The temporal contrast thresholds can be set down to 1% for negative changes in logarithmic intensity (OFF events) and down to 3.5% for positive changes (ON events). The achievement is possible through the adoption of an in-pixel preamplification stage. This preamplifier reduces the effective intrascene DR of the sensor (70 dB for OFF and 50 dB for ON), but an automated operating region control allows up to at least 110-dB DR for OFF events. A second contribution of this paper is the development of characterization methodology for measuring DVS event detection thresholds by incorporating a measure of signal-to-noise ratio (SNR). At average SNR of 30 dB, the DVS temporal contrast threshold fixed pattern noise is measured to be 0.3%–0.8% temporal contrast. Results comparing monochrome and RGBW color filter array DVS events are presented. The higher sensitivity of SDAVIS192 make this sensor potentially useful for calcium imaging, as shown in a recording from cultured neurons expressing calcium sensitive green fluorescent protein GCaMP6f.