Shiang Hu

Shiang Hu

Auto-generated profile, based on publicly available information

Shiang Hu

Anhui University

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 April 2019 in Brain Topography
Verified
Journal Article
Open access
PDF file
DYDezhong Yao
Dezhong Yao
YQYun Qin
Yun Qin
SHShiang Hu
Shiang Hu
LDLi Dong
Li Dong
MVMaria L. Bringas Vega
Maria L. Bringas Vega
PSPedro Antonio Antonio Valdes Sosa
Pedro Antonio Antonio Valdes Sosa
Which reference is appropriate for the scalp ERP and EEG studies? This unsettled problem still inspires unceasing debate. The ideal reference should be the one with zero or constant potential but unfortunately it is well known that no point on the body fulfills this condition. Consequently, more than ten references are used in the present EEG-ERP studies. This diversity seriously undermines the reproducibility and comparability of results across laboratories. A comprehensive review accompanied by a brief communication with rigorous derivations and notable properties (Hu et al. Brain Topogr, 2019. https://doi.org/10.1007/s10548-019-00706-y) is thus necessary to provide application-oriented principled recommendations. In this paper current popular references are classified into two categories: (1) unipolar references that construct a neutral reference, including both online unipolar references and offline re-references. Examples of unipolar references are the reference electrode standardization technique (REST), average reference (AR), and linked-mastoids/ears reference (LM); (2) non-unipolar references that include the bipolar reference and the Laplacian reference. We show that each reference is derived with a different assumption and serves different aims. We also note from (Hu et al. 2019) that there is a general form for the reference problem, the ‘no memory’ property of the unipolar references, and a unified estimator for the potentials at infinity termed as the regularized REST (rREST) which has more advantageous statistical evidence than AR. A thorough discussion of the advantages and limitations of references is provided with recommendations in the hope to clarify the role of each reference in the ERP and EEG practice.

25 January 2018 in Journal of Neural Engineering
Verified
Journal Article
Open access
PDF file
SHShiang Hu
Shiang Hu
YLYongxiu Lai
Yongxiu Lai
PVPedro A Valdes-Sosa
Pedro A Valdes-Sosa
MBMaria L Bringas-Vega
Maria L Bringas-Vega
DYDezhong Yao
Dezhong Yao
Human scalp electroencephalogram (EEG) is widely applied in cognitive neuroscience and clinical studies due to its non-invasiveness and ultra-high time resolution. However, the representativeness of the measured EEG potentials for the underneath neural activities is still a problem under debate. This study aims to investigate systematically how both reference montage and electrodes setup affect the accuracy of EEG potentials. First, the standard EEG potentials are generated by the forward calculation with a single dipole in the neural source space, for eleven channel numbers (10, 16, 21, 32, 64, 85, 96, 128, 129, 257, 335). Here, the reference is the ideal infinity implicitly determined by forward theory. Then, the standard EEG potentials are transformed to recordings with different references including five monopolar references (Left earlobe, Fz, Pz, Oz, Cz), and three re-references (Linked Mastoids (LM), Average Reference (AR) and Reference Electrode Standardization Technique (REST)). Finally, the relative errors between the standard EEG potentials and the transformed ones are evaluated in terms of channel number, scalp regions, electrodes layout, dipole source position and orientation, as well as sensor noise and head model. Mono-polar reference recordings are usually of large distortions; thus, a re-reference after online mono-polar recording should be adopted in general to mitigate this effect. Among the three re-references, REST is generally superior to AR for all factors compared, and LM performs worst. REST is insensitive to head model perturbation. AR is subject to electrodes coverage and dipole orientation but no close relation with channel number. These results indicate that REST would be the first choice of re-reference and AR may be an alternative option for high level sensor noise case. Our findings may provide the helpful suggestions on how to obtain the EEG potentials as accurately as possible for cognitive neuroscientists and clinicians.

7 April 2022 in NeuroImage
Verified
Journal Article
Open access
MLMin Li
Min Li
YWYing Wang
Ying Wang
CLCarlos Lopez-Naranjo
Carlos Lopez-Naranjo
SHShiang Hu
Shiang Hu
RRRonaldo César García Reyes
Ronaldo César García Reyes
PSPedro Antonio Antonio Valdes Sosa
Pedro Antonio Antonio Valdes Sosa
This paper extends frequency domain quantitative electroencephalography (qEEG) methods pursuing higher sensitivity to detect Brain Developmental Disorders. Prior qEEG work lacked integration of cross-spectral information omitting important functional connectivity descriptors. Lack of geographical diversity precluded accounting for site-specific variance, increasing qEEG nuisance variance. We ameliorate these weaknesses. (i) Create lifespan Riemannian multinational qEEG norms for cross-spectral tensors. These norms result from the HarMNqEEG project fostered by the Global Brain Consortium. We calculate the norms with data from 9 countries, 12 devices, and 14 studies, including 1564 subjects. Instead of raw data, only anonymized metadata and EEG cross-spectral tensors were shared. After visual and automatic quality control, developmental equations for the mean and standard deviation of qEEG traditional and Riemannian DPs were calculated using additive mixed-effects models. We demonstrate qEEG "batch effects" and provide methods to calculate harmonized z-scores. (ii) We also show that harmonized Riemannian norms produce z-scores with increased diagnostic accuracy predicting brain dysfunction produced by malnutrition in the first year of life and detecting COVID induced brain dysfunction. (iii) We offer open code and data to calculate different individual z-scores from the HarMNqEEG dataset. These results contribute to developing bias-free, low-cost neuroimaging technologies applicable in various health settings.

10 April 2019 in Brain Topography
Verified
Journal Article
Open access
PDF file
SHShiang Hu
Shiang Hu
DYDezhong Yao
Dezhong Yao
MBMaria L. Bringas-Vega
Maria L. Bringas-Vega
YQYun Qin
Yun Qin
PSPedro Antonio Antonio Valdes Sosa
Pedro Antonio Antonio Valdes Sosa
In this brief communication, which complements the EEG reference review (Yao et al. in Brain Topogr, 2019), we provide the mathematical derivations that show: (1) any EEG reference admits the general form of a linear transformation of the ideal multichannel EEG potentials with reference to infinity; (2) the average reference (AR), the reference electrode standardization technique (REST), and its regularized version (rREST) are solving the linear inverse problems that can be derived from both the maximum likelihood estimate (MLE) and the Bayesian theory; however, REST is based on more informative prior/constraint of volume conduction than that of AR; (3) we show for the first time that REST is also a unipolar reference (UR), allowing us to define a general family of URs with unified notations; (4) some notable properties of URs are ‘no memory’, ‘rank deficient by 1’, and ‘orthogonal projector centering’; (5) we also point out here, for the first time, that rREST provides the optimal interpolating function that can be used when the reference channel is missing or the ‘bad’ channels are rejected. The derivations and properties imply that: (a) any two URs can transform to each other and referencing with URs multiple times will not accumulate artifacts; (b) whatever URs the EEG data was previously transformed with, the minimum norm solution to the reference problem will be REST and AR with and without modeling volume conduction, respectively; (c) the MLE and the Bayesian theory show the theoretical optimality of REST. The advantages and limitations of AR and REST are discussed to guide readers for their proper use.

3 May 2018 in Frontiers in Neuroscience
Verified
Journal Article
Open access
SHShiang Hu
Shiang Hu
DYDezhong Yao
Dezhong Yao
PSPedro Antonio Antonio Valdes Sosa
Pedro Antonio Antonio Valdes Sosa
The choice of reference for the electroencephalogram (EEG) is a long-lasting unsolved issue resulting in inconsistent usages and endless debates. Currently, both the average reference (AR) and the reference electrode standardization technique (REST) are two primary, apparently irreconcilable contenders. We propose a theoretical framework to resolve this reference issue by formulating both a) estimation of potentials at infinity, and b) determination of the reference, as a unified Bayesian linear inverse problem, which can be solved by maximum a posterior estimation. We find that AR and REST are very particular cases of this unified framework: AR results from biophysically non-informative prior; while REST utilizes the prior based on the EEG generative model. To allow for simultaneous denoising and reference estimation, we develop the regularized versions of AR and REST, named rAR and rREST, respectively. Both depend on a regularization parameter that is the noise to signal variance ratio. Traditional and new estimators are evaluated with this framework, by both simulations and analysis of real resting EEGs. Towards this end, we leverage the MRI and EEG data from 89 subjects which participated in the Cuban Human Brain Mapping Project. Generated artificial EEGs—with a known ground truth, show that relative error in estimating the EEG potentials at infinity is lowest for rREST. It also reveals that realistic volume conductor models improve the performances of REST and rREST. Importantly, for practical applications, it is shown that an average lead field gives the results comparable to the individual lead field. Finally, it is shown that the selection of the regularization parameter with Generalized Cross-Validation (GCV) is close to the ‘oracle’ choice based on the ground truth. When evaluated with the real 89 resting state EEGs, rREST consistently yields the lowest GCV. This study provides a novel perspective to the EEG reference problem by means of a unified inverse solution framework. It may allow additional principled theoretical formulations and numerical evaluation of performance.

4 February 2022 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
JXJingyi Xue
Jingyi Xue
JWJinqin Wang
Jinqin Wang
SHShiang Hu
Shiang Hu
NBNing Bi
Ning Bi
ZLZhao Lv
Zhao Lv
To explore the effects of different stimuli on human emotions, olfaction has been incorporated into stimulation materials that might trigger strong emotions. In this study, we designed a new stimulation experiment and established an odor–video physiological signal database (OVPD) of odor–video stimulation for emotion recognition. The database contained the electroencephalogram (EEG) data of ten subjects acquired when experimenting with video–odor stimuli and video-only stimuli. We selected 32 video clips and ten kinds of odors (i.e., orange, rose, alcohol, water, mint, vinegar, durian, foul, acetic, and myrtle) as elicitation materials. Each subject reported a self-assessment of arousal and valence levels after the experiment ended. By comparing the brain topographies associated with two types of stimuli, olfactory stimuli increased orbitofrontal cortex activity, which is consistent with the finding from the fMRI study. Simultaneously with three types of emotions, we presented the average classification accuracies of different features using the support vector machine (SVM) classifier. The optimal accuracies with or without olfactory stimuli were 99.03% and 97.92%, respectively. The superior results show that the olfactory stimulus can enhance emotional experiences.