John M. Canik

John M. Canik

Auto-generated profile, based on publicly available information

John M. Canik

Type One Energy Group, Knoxville, TN 37931, United States of America

Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 April 2009 in Physics of Plasmas
Verified
Journal Article
Closed access
PDF file
PVP. M. Valanju
P. M. Valanju
MKM. Kotschenreuther
M. Kotschenreuther
SMS. M. Mahajan
S. M. Mahajan
JCJ. Canik
J. Canik
The Super-X Divertor (SXD), a robust axisymmetric redesign of the divertor magnetic geometry that can allow a fivefold increase in the core power density of toroidal fusion devices, is presented. With small changes in poloidal coils and currents for standard divertors, the SXD allows the largest divertor plate radius inside toroidal field coils. This increases the plasma-wetted area by 2–3 times over all flux-expansion-only methods (e.g., plate near main X point, plate tilting, X divertor, and snowflake), decreases parallel heat flux and hence plasma temperature at plate, and increases connection length by 2–5 times. Examples of high-power-density fusion devices enabled by SXD are discussed; the most promising near-term device is a 100 MW modular compact fusion neutron source “battery” small enough to fit inside a conventional fission blanket.

19 July 2012 in Nuclear Fusion
Verified
Journal Article
Closed access
JMJ.E. Menard
J.E. Menard
SGS. Gerhardt
S. Gerhardt
MBM. Bell
M. Bell
JBJ. Bialek
J. Bialek
ABA. Brooks
A. Brooks
AZA. Zolfaghari
A. Zolfaghari
The spherical tokamak (ST) is a leading candidate for a Fusion Nuclear Science Facility (FNSF) due to its compact size and modular configuration. The National Spherical Torus eXperiment (NSTX) is a MA-class ST facility in the US actively developing the physics basis for an ST-based FNSF. In plasma transport research, ST experiments exhibit a strong (nearly inverse) scaling of normalized confinement with collisionality, and if this trend holds at low collisionality, high fusion neutron fluences could be achievable in very compact ST devices. A major motivation for the NSTX Upgrade (NSTX-U) is to span the next factor of 3–6 reduction in collisionality. To achieve this collisionality reduction with equilibrated profiles, NSTX-U will double the toroidal field, plasma current, and NBI heating power and increase the pulse length from 1–1.5 s to 5–8 s. In the area of stability and advanced scenarios, plasmas with higher aspect ratio and elongation, high β N, and broad current profiles approaching those of an ST-based FNSF have been produced in NSTX using active control of the plasma β and advanced resistive wall mode control. High non-inductive current fractions of 70% have been sustained for many current diffusion times, and the more tangential injection of the 2nd NBI of the Upgrade is projected to increase the NBI current drive by up to a factor of 2 and support 100% non-inductive operation. More tangential NBI injection is also projected to provide non-solenoidal current ramp-up as needed for an ST-based FNSF. In boundary physics, NSTX measures an inverse relationship between the scrape-off layer heat-flux width and plasma current that could unfavourably impact next-step devices. Recently, NSTX has successfully demonstrated substantial heat-flux reduction using a snowflake divertor configuration, and this type of divertor is incorporated in the NSTX-U design. The physics and engineering design supporting NSTX Upgrade is described.

13 June 2012 in Nuclear Fusion
Verified
Journal Article
Closed access
RMR. Maingi
R. Maingi
DBD.P. Boyle
D.P. Boyle
JCJ.M. Canik
J.M. Canik
SKS.M. Kaye
S.M. Kaye
CSC.H. Skinner
C.H. Skinner
VSV.A. Soukhanovskii
V.A. Soukhanovskii
Lithium wall coatings have been shown to reduce recycling, suppress edge-localized modes (ELMs), and improve energy confinement in the National Spherical Torus Experiment (NSTX). Here we document the effect of gradually increasing lithium wall coatings on the discharge characteristics, with the reference ELMy discharges obtained in boronized, i.e. non-lithiated conditions. We observed a continuous but not quite monotonic reduction in recycling and improvement in energy confinement, a gradual alteration of edge plasma profiles, and slowly increasing periods of ELM quiescence. The measured edge plasma profiles during the lithium-coating scan were simulated with the SOLPS code, which quantified the reduction in divertor recycling coefficient from ∼98% to ∼90%. The reduction in recycling and fuelling, coupled with a drop in the edge particle transport rate, reduced the average edge density profile gradient, and shifted it radially inwards from the separatrix location. In contrast, the edge electron temperature (T e) profile was unaffected in the H-mode pedestal steep gradient region within the last 5% of normalized poloidal flux, ψ N ; however, the T e gradient became steeper at the top of the H-mode pedestal for 0.8 < ψ N < 0.94 with lithium coatings. The peak pressure gradients were comparable during ELMy and ELM-free phases, but were shifted away from the separatrix in the ELM-free discharges, which is stabilizing to the current-driven instabilities thought to be responsible for ELMs in NSTX.

23 February 2007 in Physical Review Letters
Verified
Journal Article
Closed access
PDF file
JCJ. M. Canik
J. M. Canik
DAD. T. Anderson
D. T. Anderson
FAF. S. B. Anderson
F. S. B. Anderson
KLK. M. Likin
K. M. Likin
JTJ. N. Talmadge
J. N. Talmadge
KZK. Zhai
K. Zhai
Differences in the electron particle and thermal transport are reported between plasmas produced in a quasihelically symmetric (QHS) magnetic field and a configuration with the symmetry broken. The thermal diffusivity is reduced in the QHS configuration, resulting in higher electron temperatures than in the nonsymmetric configuration for a fixed power input. The density profile in QHS plasmas is centrally peaked, and in the nonsymmetric configuration the core density profile is hollow. The hollow profile is due to neoclassical thermodiffusion, which is reduced in the QHS configuration.

12 November 2009 in Plasma Physics and Controlled Fusion
Verified
Journal Article
Closed access
MBM G Bell
M G Bell
HKH W Kugel
H W Kugel
RKR Kaita
R Kaita
LZL E Zakharov
L E Zakharov
HSH Schneider
H Schneider
TTthe NSTX Research Team
the NSTX Research Team

17 March 2014 in Physical Review Letters
Verified
Journal Article
Closed access
PDF file
ADA. Diallo
A. Diallo
JHJ. W. Hughes
J. W. Hughes
MGM. Greenwald
M. Greenwald
BLB. LaBombard
B. LaBombard
EDE. Davis
E. Davis
ATAlcator C-Mod Team
Alcator C-Mod Team
With fusion device performance hinging on the edge pedestal pressure, it is imperative to experimentally understand the physical mechanism dictating the pedestal characteristics and to validate and improve pedestal predictive models. This Letter reports direct evidence of density and magnetic fluctuations showing the stiff onset of an edge instability leading to the saturation of the pedestal on the Alcator C-Mod tokamak. Edge stability analyses indicate that the pedestal is unstable to both ballooning mode and kinetic ballooning mode in agreement with observations.