Husayn M. Ladha

Husayn M. Ladha

Auto-generated profile, based on publicly available information

Husayn M. Ladha

The Heart Institute, UPMC Children's Hospital of Pittsburgh, Pittsburgh, PA, USA.

Research Focus & Metrics

Academic Career Length

1Year (2026-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 April 2026 in Pediatric Cardiology
Verified
Journal Article
Open access
PDF file
HLHusayn M. Ladha
Husayn M. Ladha
JWJustin C. Wang
Justin C. Wang
YLYu Li
Yu Li
ACAdam B Christopher
Adam B Christopher
JKJacqueline Kreutzer
Jacqueline Kreutzer
TATarek Alsaied
Tarek Alsaied
Atrioventricular valve regurgitation (AVVR) remains a significant complication post-Fontan. This study evaluates the accuracy of 4D flow AVVR quantification in post-Fontan patients by comparing 4D flow to conventional echocardiographic (AVVR Echo ) and CMR assessments. Patients in the multi-institutional FORCE registry with high-quality 4D flow CMR were included. Regurgitant fractions (RFs) were calculated using two 4D-flow based methods: AVVR AVV−Ao (4D) , calculated from atrioventricular valve and aortic flows, and AVVR Jet , which directly measures AVVR jet volume. 4D flow RFs and severity classifications were compared with AVVR Echo and CMR-reported AVVR severity (AVVR Report−Cat ), and examiner-reported RFs (AVVR Report−RF ). Statistical tests included Pearson correlation, Cohen’s kappa, and Bland-Altman analysis. The study included 218 post-Fontan patients (median age: 16.2 years, IQR: 12.8–22.5) and 36.2% were female. Both 4D flow methods displayed excellent interobserver reproducibility (interclass correlation > 0.95) and RFs approximately 7% lower than AVVR Report−RF . AVVR AVV−Ao (4D) showed stronger agreement with AVVR Report−RF (κ = 0.50 [95% CI: 0.25–0.75]; r = 0.49, p < 0.01). AVVR Jet demonstrated better concordance with AVVR Report−Cat (κ = 0.31 [95% CI: 0.17–0.45]). Both AVVR AVV−Ao (4D) (OR = 1.53, p = 0.004; AUC = 0.71) and AVVR Jet (OR = 1.74, p = 0.002; AUC = 0.65) were associated significantly with the composite outcome of death and heart transplantation listing. This is the first study analyzing the accuracy of 4D flow AVVR quantification in post-Fontan patients, demonstrating reproducibility, prognostic value, and good concordance with conventional methods. These findings suggest that 4D flow AVVR quantification may serve as a complementary method for assessing AVVR in post-Fontan patients.

15 July 2026 in Pediatric Cardiology
Verified
Journal Article
Open access
HLHusayn M. Ladha
Husayn M. Ladha
JWJustin C. Wang
Justin C. Wang
YLYu Li
Yu Li
ACAdam B Christopher
Adam B Christopher
JKJacqueline Kreutzer
Jacqueline Kreutzer
TATarek Alsaied
Tarek Alsaied