Shingo Toyota

Shingo Toyota

Auto-generated profile, based on publicly available information

Shingo Toyota

Department of Neurosurgery, Kansai Rosai Hospital

Research Focus & Metrics

Academic Career Length

23Years (2004-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2020 in Neurologia medico-chirurgica
Verified
Journal Article
Open access
PDF file
TSTakeshi Shimizu
Takeshi Shimizu
STShingo Toyota
Shingo Toyota
KNKanji Nakagawa
Kanji Nakagawa
TMTomoaki Murakami
Tomoaki Murakami
KMKanji Mori
Kanji Mori
TTTakuyu Taki
Takuyu Taki
One of the merits of recently introduced exoscopes, including ORBEYE, is that they are superior to a conventional microscope in terms of ergonomic features. Taking advantage of it, the retrosigmoid approach can be performed in the supine position using ORBEYE. We report a consecutive series of 14 operations through the retrosigmoid approach in the supine position using ORBEYE. Fourteen consecutive patients who underwent surgery through the retrosigmoid approach for cerebellopontine (CP) angle lesions in the supine position using ORBEYE were targeted, and surgical outcomes and complications were examined. We evaluated the posture of the operator and the surgical field during this approach compared with those using a conventional microscope. In all 14 cases, all operative procedures were accomplished only using the ORBEYE. There were no operative complications due to this approach. Using ORBEYE, even when the angle of the operative visual axis was horizontal, the operators could manipulate in a comfortable posture. They were not forced to be in an uncomfortable posture that extended their arms, as is often the case with a conventional microscope. Therefore, they could use shorter surgical instruments. As the cerebellum shifted downward with gravity even using slight retraction during this approach, the working space of the surgical field was easily secured. Through this approach, the operators can perform stable microsurgery of CP angle lesions in a comfortable posture. This approach can reduce the burden on the operator and the patient, leading to a refined surgical procedure.

1 October 2004 in min - Minimally Invasive Neurosurgery
Verified
Journal Article
Closed access
PDF file
STS. Toyota
S. Toyota
TTT. Taki
T. Taki
SOS. Oshino
S. Oshino
THT. Hashiba
T. Hashiba
YOY. Oku
Y. Oku
TYT. Yoshimine
T. Yoshimine
Objectives: We have tried to approach the aqueduct less invasively with the endoscope in combination with a small suboccipital craniectomy, especially for lesions of the aqueduct close to the fourth ventricle. Methods: The patient is placed in the prone position and a small suboccipital craniectomy is performed. After elevating the bilateral tonsils with retractors, the sheath of the endoscope is inserted from a small skin incision made on the posterior midline of the neck, far from the craniectomy site. The skin incision for endoscopic insertion is planned on the linear extension connecting the aqueduct and the foramen of Magendi on the craniocervical MRI. A rigid endoscope is inserted through the fourth ventricle to the aqueduct for exploration and surgical manipulation. Results: Two cases with hydrocephalus due to aqueductal stenosis, with gait disturbance were operated. After exploration of the aqueduct via the fourth ventricle, endoscopic aqueductal plasty was performed. The postoperative courses were uneventful. The patients' symptoms disappeared. Conclusions: This approach can be applied for less invasive endoscopic exploration and surgery around the aqueduct close to the fourth ventricle with a rigid endoscope, without overflexion of the neck, or a large craniectomy, or overretraction of the tonsils, or incision of the inferior vermis.

1 March 2004 in Journal of Neurosurgery
Verified
Journal Article
Closed access
STShingo Toyota
Shingo Toyota
HTHiroshi Takimoto
Hiroshi Takimoto
JKJun Karasawa
Jun Karasawa
AKAmami Kato
Amami Kato
TYToshiki Yoshimine
Toshiki Yoshimine
The purpose of this study was to analyze the change in cardiac sympathetic function by performing a 123I-metaiodobenzylguanidine (MIBG) imaging study after endoscopic upper thoracic sympathectomy (EUTS) in patients with palmar hyperhidrosis before and after surgery. Between February 1999 and February 2002, 135 patients underwent bilateral EUTS to treat palmar hyperhidrosis. Between September 2001 and February 2002, 12 of these consecutively enrolled patients were also included in a 123I-MIBG imaging study. These patients underwent cardiac 123I-MIBG imaging 1 day before and 7 days after they had undergone EUTS. The heart/mediastinum (H/M) ratio and the washout rate were calculated for both early and late phases, and single-photon emission computerized tomography (SPECT) imaging of the early phase was performed. Excessive perspiration from the palms disappeared immediately after EUTS in all patients, and they showed no symptoms of a circulatory condition following the procedure. On the 123I-MIBG imaging studies, the early H/M ratio before EUTS was 2.35 +/- 0.26 and postoperatively it was 2.29 +/- 0.23. The delayed H/M ratio before EUTS was 2.59 +/- 0.3 and after the procedure it was 2.66 +/- 0.27. There was no significant difference between the H/M ratio before and after EUTS. The washout rate after EUTS (14.27 +/- 4.71%) was significantly lower than that measured before EUTS (18.36 +/- 5.13%: p < 0.01). No apparent local defects of accumulation of MIBG were found on SPECT images obtained post-EUTS. Endoscopic upper thoracic sympathectomy is a minimally invasive procedure; no local denervation was found after EUTS. Findings on 123I-MIBG imaging studies indicate that EUTS suppresses the activation of the sympathetic nervous system slightly, similar to beta-blocker therapy.

1 September 2018
Verified
Book Chapter
Closed access
PDF file
STShingo Toyota
Shingo Toyota
TKTetsuya Kumagai
Tetsuya Kumagai
TGTetsu Goto
Tetsu Goto
KMKanji Mori
Kanji Mori
TTTakuyu Taki
Takuyu Taki

1 August 2009 in min - Minimally Invasive Neurosurgery
Verified
Journal Article
Closed access
PDF file
STS. Toyota
S. Toyota
YFY. Fujimoto
Y. Fujimoto
FIF. Iwamoto
F. Iwamoto
AWA. Wakayama
A. Wakayama
TYT. Yoshimine
T. Yoshimine
Introduction: In coil embolization of paraclinoid aneurysms, it is sometimes difficult to introduce and stabilize microcatheter tips in the aneurysms. We report a new technique for shaping microcatheter tips in the coil embolization of paraclinoid aneurysms. Methods: From May 2007 to May 2008, this new technique was applied to 10 paraclinoid aneurysms undergoing coil embolization. Before coil embolization, 3D rotational angiography was performed, and volume-rendering images were reconstructed. Vinyl-coated handicraft wire was shaped 3-dimensionally to fit full-scale volume-rendering images on the monitor, from the C5 portion of the internal carotid artery to the center of the dome of the aneurysm from various angles. The microcatheter tip was then shaped with steam to fit the vinyl-coated wire. Thereafter, the microcatheter tip was introduced into the aneurysm and coil embolization was performed. Results: Microcatheter tips could be easily shaped and could be introduced smoothly into aneurysms, and were stable during coil embolization. Conclusion: This technique is feasible for shaping microcatheter tips precisely for coil embolization of paraclinoid aneurysms.

1 September 2021 in Asian Journal of Neurosurgery
Verified
Journal Article
Open access
PDF file
TMTomoaki Murakami
Tomoaki Murakami
STShingo Toyota
Shingo Toyota
TSTakuya Suematsu
Takuya Suematsu
YWYuki Wada
Yuki Wada
KNKanji Nakagawa
Kanji Nakagawa
TTTakuyu Taki
Takuyu Taki
We have developed a new educational approach to microsurgery in which a trainee and supervisor can cooperate with “4 hands” using the exoscope. We evaluated 4-hands surgery for intracranial hemorrhage (ICH) using the exoscope to validate the educational value and ergonomic advantages of this method. Thirty consecutive patients who underwent surgery for ICH using the exoscope between December 2018 and May 2020 were studied retrospectively. All operations were performed by a team comprising a supervisor (assistant) and a trainee (main operator). The assistant set the visual axis of the exoscope, and adjusted focus and magnification as a scopist. After setting the ORBEYE, the supervisor helped retract the brain and withdraw and irrigate the hematoma using suction tubes or brain retractors. Moreover, the trainee evacuated the hematoma with a suction tube and coagulated using bipolar forceps. Patient background and results of treatment were evaluated. Intraoperative postures of the operators were observed, and schemas compared with the use of a conventional microscope were developed. All microsurgical procedures were accomplished by a trainee with a supervisor using only the exoscope. During the surgery, the surgeons could work in a comfortable posture, and the supervisor and trainee could cooperate in microsurgical procedures using their four hands. The results of the present case series concerning evacuation of ICH were not inferior to those described in previous reports. To increase opportunities for education in microsurgery, 4-hands surgery for ICH using the exoscope appears feasible and safe and offered excellent educational value and ergonomic advantages.