Felipe Jose Lachovicz

Felipe Jose Lachovicz

Auto-generated profile, based on publicly available information

Felipe Jose Lachovicz

Instituto de Tecnologia para o Desenvolvimento (LACTEC), Curitiba, Brazil

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 October 2021 in IEEE Access
Verified
Journal Article
Open access
RSRicardo Schumacher
Ricardo Schumacher
FLFelipe Jose Lachovicz
Felipe Jose Lachovicz
PMPablo Lopes Macedo
Pablo Lopes Macedo
FPFilipe Perez
Filipe Perez
LMLucio De Medeiros
Lucio De Medeiros
RKRomao Kowaltschuk
Romao Kowaltschuk
The operation of power systems under peak demand conditions results in higher operational costs, more instability risks and often forces an excessive use of fossil fuels. In this context, this paper proposes a self-sustainable real-time pricing (RTP) tariff that is adjusted proportionally to the aggregated demand of a group of consumers, and is based on a changing rate for each hour of the day. Therefore, demand peaks are expected to be naturally reduced by the group due to the higher tariff values imposed during these operating conditions. In addition, consumers benefit from the opportunity to reduce their bills according to the tariff and can carry out financial strategies by setting up their own consumption profile. The proposed dynamic tariff has a self-sustainable and revenue neutral nature which protects both consumers and distribution power companies from being economically affected by varying price elasticity scenarios. This is achieved by mathematically guaranteeing for such companies a revenue equal to the one they would expect with the traditional application of flat tariff. The advantages of the proposal are highlighted through numerical simulations by comparing it with the so-called Conventional Tariff and White Tariff, which are currently adopted by residential consumers in Brazil.

4 April 2023 in Journal of Control, Automation and Electrical Systems
Verified
Journal Article
Closed access
PDF file
FLFelipe J. Lachovicz
Felipe J. Lachovicz
TFThelma Solange Piazza Fernandes
Thelma Solange Piazza Fernandes
JJJoão Américo Vilela Jr
João Américo Vilela Jr

18 August 2021 in Journal of Control, Automation and Electrical Systems
Verified
Journal Article
Closed access
PDF file
FLFelipe J. Lachovicz
Felipe J. Lachovicz
TFThelma Solange Piazza Fernandes
Thelma Solange Piazza Fernandes
MBMarcelo R. Bessa
Marcelo R. Bessa
KGKlaus de Geus
Klaus de Geus

7 May 2025 in IEEE Access
Verified
Journal Article
Open access
FLFelipe J. Lachovicz
Felipe J. Lachovicz
KKKristie K. Küster
Kristie K. Küster
AOAna Paula PAULA Oening
Ana Paula PAULA Oening
DMDébora C. Marcilio
Débora C. Marcilio
GSGuilherme M. F. Souza
Guilherme M. F. Souza
RSRobinson A. Silva
Robinson A. Silva
Planning the construction of an offshore wind power plant involves balancing design details that affect both technical and financial viability. The electrical balance of plant is a significant part of installation costs, and modeling it can help developers optimize solutions and reduce expenses. This paper presents an approach to model the electrical balance of plant, including inter-array cable routing and sizing, the number and size of HVAC and HVDC export cables, optimized reactive power compensation, offshore and onshore equipment, and grid connection transmission line. The model also accounts for the physical dimensions and weight of offshore and onshore substation components that are significant information for planning further steps such as the constructibility and foundation. This approach is part of CPE-Offshore, software designed to support decision-making for Brazilian offshore wind farms, considering 60 Hz 138 kV and 230 kV HVAC transmission voltages. A generic 1920 MW Brazilian wind farm located 65 km from shore is used as a case study to demonstrate results for different numbers of offshore substations. Additionally, a sensitivity analysis explores reactor combinations and cost comparisons between HVAC and HVDC systems for various plant capacities and distances to the coast. The results indicate a break-even distance of up to 180 km and the most suitable combinations to be evaluated for a 60 Hz system to avoid waste of computational time. This electrical balance of plant approach can be applied to plan an offshore wind power plant in other regions worldwide.