Xin Wang

Xin Wang

Auto-generated profile, based on publicly available information

Xin Wang

Department of Ultrasound, Peking Union Medical College Hospital, Beijing, China

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 May 2024 in BMC Medical Informatics and Decision Making
Verified
Journal Article
Open access
JZJun Zhou
Jun Zhou
XWXin Wang
Xin Wang
YLYiyao Li
Yiyao Li
YYYuqing Yang
Yuqing Yang
JSJuhong Shi
Juhong Shi
Background: Acute pulmonary thromboembolism (PTE) is a common cardiovascular disease and recognizing low prognosis risk patients with PTE accurately is significant for clinical treatment. This study evaluated the value of federated learning (FL) technology in PTE prognosis risk assessment while ensuring the security of clinical data. Methods: A retrospective dataset consisted of PTE patients from 12 hospitals were collected, and 19 physical indicators of patients were included to train the FL-based prognosis assessment model to predict the 30-day death event. Firstly, multiple machine learning methods based on FL were compared to choose the superior model. And then performance of models trained on the independent (IID) and non-independent identical distributed(Non-IID) datasets was calculated and they were tested further on Real-world data. Besides, the optimal model was compared with pulmonary embolism severity index (PESI), simplified PESI (sPESI), Peking Union Medical College Hospital (PUMCH). Results: The area under the receiver operating characteristic curve (AUC) of logistic regression(0.842) outperformed convolutional neural network (0.819) and multi layer perceptron (0.784). Under IID, AUC of model trained using FL(Fed) on the training, validation and test sets was 0.852 ± 0.002, 0.867 ± 0.012 and 0.829 ± 0.004. Under Real-world, AUC of Fed was 0.855 ± 0.005, 0.882 ± 0.003 and 0.835 ± 0.005. Under IID and Real-world, AUC of Fed surpassed centralization model(NonFed) (0.847 ± 0.001, 0.841 ± 0.001 and 0.811 ± 0.001). Under Non-IID, although AUC of Fed (0.846 ± 0.047) outperformed NonFed (0.841 ± 0.001) on validation set, it (0.821 ± 0.016 and 0.799 ± 0.031) slightly lagged behind NonFed (0.847 ± 0.001 and 0.811 ± 0.001) on the training and test sets. In practice, AUC of Fed (0.853, 0.884 and 0.842) outshone PESI (0.812, 0.789 and 0.791), sPESI (0.817, 0.770 and 0.786) and PUMCH(0.848, 0.814 and 0.832) on the training, validation and test sets. Additionally, Fed (0.842) exhibited higher AUC values across test sets compared to those trained directly on the clients (0.758, 0.801, 0.783, 0.741, 0.788). Conclusions: In this study, the FL based machine learning model demonstrated commendable efficacy on PTE prognostic risk prediction, rendering it well-suited for deployment in hospitals.

16 March 2023 in Asian Nursing Research
Verified
Journal Article
Open access
XWXin Wang
Xin Wang
RTRongsong Tang
Rongsong Tang
HZHeli Zhang
Heli Zhang
LFLi Fan
Li Fan
JWJing Wang
Jing Wang
BLBaohua Li
Baohua Li
Ankle pump exercises (APE) have been widely used in clinical practice. However, best practices for APE have not been established. Recognize the most effective frequency of APE for improving lower extremity hemodynamics and establish recommendations in clinical practice. Therefore, a systematic review and network meta-analysis (NMA) was performed according to PRISMA-NMA. Six English databases (Pubmed, Medline, CINAHL, Embase, the Cochrane library and ProQuest) and four Chinese databases (CNKI, Wanfang, VIP and Sinomed) were searched. Randomized controlled trials (RCTs) and quasi-experimental studies investigating the effects of different frequencies of APE on lower limb hemodynamics published before July 2022 were included. The reference list was also searched. Seven studies (one RCTs and six quasi-experimental studies) were included in the systematic review and five studies (one RCTs and four quasi-experimental studies) were included in the NMA. The risk of bias was assessed using the Cochrane and Joanna Briggs Institute tools. The NMA was performed using the R software (version 4.2.1) and OpenBUGS (version 3.2.3). The results of the NMA showed that a frequency of every 3-4 s the most effective in improving lower extremity hemodynamics (P =.85), followed by every 1-2 s (P = .81), every 5-6 s (P=.32) and less than every 10 s (P =.02). Subgroup analysis failed to find a difference between healthy participants and those with unilateral total hip arthroplasty or fracture (MD = -0.23, 95% CI-5.92 to 4.61). Consequencely, for adult patients, with or without lower extremity disease, a frequency of every 3-4 s can be recommended as the optimal frequency of APE in clinical care practice. CRD42022349365. https://www.crd.york.ac.uk/PROSPERO/display_record.php?RecordID=349365.