1 January 2018 in The Ocular Surface
ABAlireza Baradaran-Rafii
+2
25 April 2018 in Electronic Physiciane
Changes in corneal thickness and corneal endothelial cell density after phacoemulsification cataract surgery: a double-blind randomized trial
1 January 2015 in Middle East African Journal of Ophthalmology
Purpose: To evaluate changes in corneal topography and biomechanical properties after collagen cross-linking (CXL) for progressive keratoconus. Patients and Methods: Collagen cross-linking was performed on 97 eyes. We assessed uncorrected visual acuity (UCVA) and best corrected visual acuity (BCVA). Corneal topography indices were evaluated using placido disc topography, scanning slit anterior topography (Orbscan II), and rotating Scheimpflug topography (Pentacam). Specular microscopy and corneal biomechanics were evaluated. Results: A 1-year-follow-up results revealed that UCVA improved from 0.31 to 0.45 and BCVA changed from 0.78 to 0.84 (P < 0.001). The mean of average keratometry value decreased from 49.62 to 47.95 D (P < 0.001). Astigmatism decreased from 4.84 to 4.24 D (P < 0.001). Apex corneal thickness decreased from 458.11 to 444.46 mm. Corneal volume decreased from 56.66 to 55.97 mm 3 (P < 0.001). Posterior best fit sphere increased from 55.50 to 46.03 mm (P = 0.025). Posterior elevation increased from 99.2 to 112.22 mm (P < 0.001). Average progressive index increased from 2.26 to 2.56 (P < 0.001). A nonsignificant decrease was observed in mean endothelial count from 2996 to 2928 cell/mm 2 (P = 0.190). Endothelial coefficient of variation (CV) increased nonsignificantly from 18.26 to 20.29 (P = 0.112). Corneal hysteresis changed from 8.18 to 8.36 (P = 0.552) and corneal resistance factor increased from 6.98 to 7.21(P = 0.202), so these changes were not significant. Conclusion: Visual acuity and K values improved after CXL. In spite of the nonsignificant increase in endothelial cell count and increase in the CV, CLX seems to be a safe treatment for keratoconus. Further studies with larger sample sizes and longer follow-up periods are recommended.
1 November 2018 in Eye & Contact Lens: Science & Clinical Practice
Background: Use of patient-reported outcomes to evaluate the impact of ocular conditions on quality of life (QoL) is rising. Hence, the aims of this study were to determine the impact of keratoconus on QoL, and assess the National Eye Institute of the United States Vision Function Questionnaire (NEI-VFQ) performance in an Iranian population. Methods: From November 2016 to June 2017, patients with keratoconus definitive diagnosis for more than one year who were being routinely followed at a cornea clinic were recruited. The NEI-VFQ-25 was administered during a face-to-face interview. Ocular examinations comprised best-corrected visual acuity (BCVA) was logged monocularly and binocularly, anterior segment biomicroscopy, refraction, and corneal topography. Keratoconus severity was graded based on steep keratometric (K) reading values. A group of 30 age- and sex-matched subjects with other ocular diseases (except keratoconus) were selected randomly from the cornea clinic. P<0.05 was considered as significant. Results: The mean age of participants was 28.7±7.6 years. The lowest NEI-VFQ subscale scores were related to ocular pain, general vision, mental health, and role difficulty. Almost all NEI-VFQ scores in patients were statistically significant less than mean score of the control group. Composite and all subscales NEI-VFQ scores were lower significantly among patients with higher disease duration (≥5 years). Among clinical data, patients with BCVA ≥0.5 in the better eye had significantly lower NEI-VFQ composite score. Severe keratoconus patients (steep K reading ≥52) had lower NEI-VFQ scores in mental health and dependency subscales (P<0.05). The overall and subscales Cronbach α was above 0.7. Conclusion: Iranian patients with keratoconus had physical, emotional, and social impairment in QoL. The NEI-VFQ-25 might be applicable in further studies.
28 September 2020 in Journal of Optometry
To evaluate the agreement of dry, and cycloplegic autorefraction and wavefront-based refraction with subjective refraction. 83 subjects aged 19–57 years were included in this cross-sectional study. Refractive status was determined using four methods including subjective refraction, wavefront-based refraction, dry and cycloplegic autorefraction. Refractive data were recorded as sphere, cylinder and spherical equivalent (SE). Power vector components were used to compare the astigmatism obtained using the different methods of refraction. The more negative spherical, cylindrical and SE components were obtained using dry autorefraction, wavefront-based refraction and dry autorefraction, respectively. The less negative spherical, cylindrical and SE components were obtained using cycloplegic autorefraction, subjective refraction and cycloplegic autorefraction, respectively. Considering the spherical component, there was a statistically significant hyperopic shift (0.12 ± 0.29 D, p = 0.001) with cycloplegic autorefraction and a significant myopic shift (−0.17 ± 0.32 D, p < 0.001) with dry autorefraction compared to subjective refraction, while the difference between wavefront-based and subjective refraction was not significant statistically (p = 0.145). The calculated cylindrical component using subjective refraction showed statistically significant difference with dry auto-refraction (p < 0.001), cycloplegic auto-refraction (p = 0.041) and wavefront refraction (p < 0.001). The highest correlation with subjective refraction in sphere, cylinder and SE was observed for cycloplegic auto-refraction (rs = 0.967), dry auto-refraction (rs = 0.983) and cycloplegic auto-refraction (rs = 0.982), respectively. As subjective refraction is gold standard in our study, sphere in cycloplegic auto-refraction and astigmatism in dry auto-refraction showed better agreement and correlation.