Yuehuan Lin

Yuehuan Lin

Auto-generated profile, based on publicly available information

Yuehuan Lin

Electric Power Research Institute, China Southern Power Grid Co Ltd., Guangzhou, 510000, China

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 July 2020 in IEEE Access
Verified
Journal Article
Open access
AXAncheng XUE
Ancheng XUE
HKHe Kong
He Kong
YLYongzhao Lao
Yongzhao Lao
QXQuan Xu
Quan Xu
YLYuehuan Lin
Yuehuan Lin
GWGuoen Wei
Guoen Wei
Accurate transmission line parameters are the basis of power system calculations. Aiming at obtaining accuracy online transmission line parameters in the case of large random noises even bad data in Phasor Measurement Unit (PMU) measurements, which occurs frequently in the practice, a new adaptive robust identification method combining adaptive linear neuron (ADALINE) and traditional robust IGG (Institute of Geodesy & Geophysics, Chinese Academy of Sciences) method is proposed. In detail, first, the identification model of transmission line parameters is presented based on the multi-period PMU measurements at both ends of the transmission line. Then, a parameter solving model based on ADALINE is established. Furthermore, to fully use measurement information, the adaptive robust ADALINE (ARA) are proposed, which applies the robust IGG weight function (Scheme I) to ADALINE to realize “three segments” robust identification. In addition, to improve the robustness, the expectation and variance of the equation residual sequence are estimated adaptively with the median principle to adjust the threshold for the IGG function to assure robustness (TAR), which is independent of the known information for the error of the measurement equipment. The cases based on PSCAD simulated data and measured data show the effectiveness and engineering practicality of the proposed method.

25 September 2020 in IEEE Access
Verified
Journal Article
Open access
AXAncheng XUE
Ancheng XUE
SLShuang Leng
Shuang Leng
YLYongzhao Lao
Yongzhao Lao
QXQuan Xu
Quan Xu
YLYuehuan Lin
Yuehuan Lin
GWGuoen Wei
Guoen Wei
Phasor measurement unit (PMU), which could provide high-frequency phasors including the amplitude and phase angle synchronized with Global Positioning System (GPS)/BeiDou Navigation Satellite System (BDS) signal, plays a vital role in dynamic monitoring of power systems. However, if the GPS/BDS signal could not be received, the time of PMU, which depends on the crystal oscillator (CO), would cause measurement deviation due to frequency shifts of CO, and then the PMU data would engage deviations and deteriorate the relevant applications. In recognizing the above problems, this paper proposes a method to detect the frequency deviation of the crystal oscillator (FDCO) based on the correlation coefficient, according to its relation with the characteristic of the voltage phase angle difference(VPAD) between the two ends of the line. In detail, firstly, the quality of the VPAD of PMU between the two ends of the line is analyzed and the related problem is stated. Secondly, the characteristics of PMU data, when FDCO exists, are derived and analyzed, especially the VPAD between the line, and the suitability of the data for detecting the FDCO is discussed. Thirdly, the ideas and specific methods of detecting the FDCO in case of malfunction of GPS/BDS signal are proposed. Furthermore, the validity of the proposed method with simulation data and modified measured data is presented. Finally, the conjectures on the reasons for the approximately constant VPAD deviation in the previous section are discussed.

7 April 2021
Verified
Conference Paper
Closed access
XQXu Quan
Xu Quan
LYLian Yin
Lian Yin
ZYZhi-Yong Yuan
Zhi-Yong Yuan
LYLin Yuehuan
Lin Yuehuan
LYLiu Yinliang
Liu Yinliang
ZSZhang Xu Sheng
Zhang Xu Sheng
With the access of large-scale distributed power and electric vehicles, the operation state of modern distribution network is more complex and changeable. In this paper, kinds of operation scenarios that may occur in the field operation of the system are fully considered. Combined with the wide area measurement and control system function of the distribution network, the test scheme is designed based on the actual distribution network and a typical test case is established. The typical network parameters of the actual distribution network are calculated and a typical 28-nodes distribution network simulation example is established. The artificial short circuit test based on unmanned aerial vehicle is carried out to verify the correctness of the simulation example. The test results verify the correctness of the proposed example. Based on the real-time digital simulation system and dynamic simulation experiment system, the test platform of wide area measurement and control system in distribution network is built. Through the multi scene real-time digital simulation test, the state estimation, fault diagnosis and positioning, coordinated control and other advanced application control effects can be checked. Through the hardware in the loop test and dynamic simulation experiment based on real-time digital simulation, the distribution network Phasor Measurement Unit (DPMU) and master station of distribution network wide area measurement control system can be tested.