Chi Zhu

Chi Zhu

Auto-generated profile, based on publicly available information

Chi Zhu

Peking University

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 October 2022 in Journal of Open Source Software
Verified
Journal Article
Open access
PDF file
CZChi Zhu
Chi Zhu
VVVijay Vedula
Vijay Vedula
DPDave Parker
Dave Parker
NWNathan Wilson
Nathan Wilson
SSShawn Shadden
Shawn Shadden
AMAlison Marsden
Alison Marsden

19 July 2018 in Journal of Fluid Mechanics
Verified
Journal Article
Closed access
PDF file
CZChi Zhu
Chi Zhu
JSJung-Hee Seo
Jung-Hee Seo
Rajat MittalRajat Mittal
Rajat Mittal
In a study motivated by considerations associated with heart murmurs and cardiac auscultation, numerical simulations are used to analyse the haemodynamics in a simple model of an aorta with an aortic stenosis. The aorta is modelled as a curved pipe with a $180^{\circ }$ turn, and three different stenoses with area reductions of 50 %, 62.5 % and 75 % are examined. A uniform steady inlet velocity with a Reynolds number of 2000 is used for all of the cases and direct numerical simulation is employed to resolve the dynamics of the flow. The poststenotic flow is dominated by the jet that originates from the stenosis as well as the secondary flow induced by the curvature, and both contribute significantly to the flow turbulence. On the anterior surface of the modelled aorta, the location with maximum pressure fluctuation, which may be considered as the source location for the murmurs, is found to be located around $60^{\circ }$ along the aortic arch, and this location is relatively insensitive to the severity of the stenosis. For all three cases, this high-intensity wall pressure fluctuation includes contributions from both the jet and the secondary flow. Spectral analysis shows that for all three stenoses, the Strouhal number of the vortex shedding of the jet shear layer is close to 0.93, which is higher than the shedding frequency of a corresponding free jet or a jet confined in a straight pipe. This frequency also appears in the pressure spectra at the location postulated as the source of the murmurs, in the form of a ‘break frequency.’ The implications of these findings for cardiac auscultation-based diagnosis of aortic stenosis are also discussed.

12 June 2024 in Computer Methods in Applied Mechanics and Engineering
Verified
Journal Article
Closed access
YLYao Lu
Yao Lu
PWPeishuo Wu
Peishuo Wu
MLMoubin Liu
Moubin Liu
CZChi Zhu
Chi Zhu

1 June 2019 in Journal of Computational Physics
Verified
Journal Article
Closed access
CZChi Zhu
Chi Zhu
JSJung-Hee Seo
Jung-Hee Seo
Rajat MittalRajat Mittal
Rajat Mittal

19 December 2023 in Journal of Fluid Mechanics
Verified
Journal Article
Closed access
PDF file
PWPeishuo Wu
Peishuo Wu
CZChi Zhu
Chi Zhu
In this paper, we present an analytic solution for pulse wave propagation in a flexible arterial model with tapering, physiological boundary conditions and variable wall properties (wall elasticity and thickness). The change of wall properties follows a profile that is proportional to $r^\alpha$ , where $r$ represents the lumen radius and $\alpha$ is a material coefficient. The cross-sectionally averaged velocity and pressure are obtained by solving a hyperbolic system derived from the mass and momentum conservations, and they are expressed in Bessel functions of order $(4-\alpha )/(3-\alpha )$ and $1/(3-\alpha )$ , respectively. The solution is successfully validated by comparing it with numerical results from three-dimensional (3-D) fluid–structure interaction simulations. Subsequently, the solution is employed to study pulse wave propagation in an arterial model, revealing that the wall properties and the physiological outlet boundary conditions, such as the resistor–capacitor–resistor (RCR) model, play a crucial role in characterizing the input impedance and reflection coefficient. At low-frequency range, the input impedance is found to be insensitive to the wall properties and is primarily determined by the RCR parameters. At high-frequency range, the input impedance oscillates around the local characteristic impedance, and the oscillation amplitude varies non-monotonically with $\alpha$ . Expressions for the input impedance at both low-frequency and high-frequency limits are presented. This analytic solution is also successfully applied to model flow inside a patient-specific arterial tree, with the maximum relative errors in pressure and flow rate never exceeding $1.6\,\%$ and $9.0\,\%$ when compared with results from 3-D numerical simulations.

1 January 2024 in Physics of Fluids
Verified
Journal Article
Closed access
PDF file
JWJunjie Wang
Junjie Wang
ZHZhanzhou Hao
Zhanzhou Hao
BYBo Yin
Bo Yin
WTWenchang Tan
Wenchang Tan
CZChi Zhu
Chi Zhu
Accurate measurement of trans-stenotic pressure drop is vital for risk stratification in coronary artery disease. Currently, in vivo pressure measurement relies mostly on a pressure guidewire inserted into the artery, which inevitably alters local hemodynamics. To precisely assess the impact of guidewire insertion on the accuracy of pressure measurement, this study conducts numerical simulations with both an idealized straight-tube model and a patient-specific model. Results with and without a guidewire model are compared and analyzed. Results from the idealized model reveal that the insertion of a guidewire shifts velocity distribution, increases resistance, and amplifies the pressure drop across the stenosis. The patient-specific model also demonstrates that the guidewire causes non-negligible flow redistribution among the arterial branches, but the influence on pressure drop remains mostly localized. An analytical model for trans-stenotic pressure drop that takes the guidewire into consideration is also proposed and validated against the 3D simulation results. It is observed that the maximum relative error is around 3.0% in the patient-specific model, indicating the effectiveness of the analytical model in physiologically accurate settings. The proposed model can be used to align computed tomography-derived fractional flow reserve values with clinically recognized FFR standards established through guidewire measurements.