9 August 2017 in Neurodegenerative Diseases
Background: Growth differentiation factor 15 (GDF15) has been shown to be protective for dopaminergic neurons in animal and ex vivo experiments. However, little i
18 September 2018 in Journal of Physics D: Applied Physics
In this paper, an improved corona discharge in air at atmospheric pressure is ignited by a MgO/NiO/Ni sandwich cathode with high secondary electron emission and is then employed for volatile organic compound degradation. Current–voltage characteristics, discharge images, and spectroscopic investigations are compared for two corona discharges with a MgO/NiO/Ni cathode and a Ni cathode, respectively. The discharge current with the MgO/NiO/Ni cathode is about 2.5–3.3 times larger than the one with the Ni cathode at various applied voltages from 12 to 19 kV. Besides, discharge images show that, as well as the expected glow discharge around the needle tips, luminous points also occur on the surface of the MgO/NiO/Ni cathode simultaneously, indicating that ionization and excitation processes take place around the cathode surface. This is attributed to the fact that an internal field within the oxide layer calculated by the measured surface potential, which is induced by positive charges accumulated on the oxide layers, is sufficient to induce field emission and further cause the improved corona discharge generation. Such improved corona discharge with the MgO/NiO/Ni cathode is then applied to toluene degradation, and the toluene degradation efficiency and energy yield are much higher than those with the Ni cathode, respectively.
13 December 2019 in Journal of Physics D: Applied Physics
The degradation of toluene by DC discharge has been evaluated in a multi-wire-plate reactor with MgO/NiO/Ni (MNN) cathode and compared with a normal discharge with Ni cathode. The effects of various operating parameters, including the position distribution of wire electrodes, discharge gap, gas flow rate and toluene initial concentration have been systematically investigated. Morphological characterizations demonstrate that in addition to the normal discharge around the wire electrodes, extra discharge also occurs on the MNN cathode surface which is mainly concentrated in the vertical corresponding region of the wire electrodes and diffuses to both sides. The position distribution of two wires influences the total discharge current. It is because that it affects not only the discharge around the wire electrode, but also the discharge on MNN cathode surface. Beside, a wire–wire spacing of 25 mm in discharge reactor with MNN cathode is optimized due to a relative large discharge current. A small discharge gap between wire electrode and cathode contributes to the improvement of toluene degradation and mineralization and it is optimized of 15.3 mm. The effects of discharge power, gas flow rate and toluene initial concentration and the interactions between these parameters on toluene removal performance by discharge with MNN cathode are investigated using Box–Behnken design (BBD). The analysis of variance (ANOVA) is employed to evaluate the significance of the independent variables and their interactions. The results show that the initial concentration plays the most important role in determining the toluene removal efficiency, while discharge power is the most significant factor affecting the energy efficiency in this discharge process.
1 October 2026 in IEEE Transactions on Industrial Electronics
In DC grids, multiple DC circuit breakers (DCCBs) on a DC bus can be replaced by a multiport DCCB (MDCCB) to reduce the investment cost. However, compared with a single DCCB, the MDCCB contains more branches and has a greater probability of branch unavailability; furthermore, its interruption failure caused by branch unavailability leads to more severe consequences. A few studies avoid the interruption failure caused by ultrafast disconnector (UFD) failure, but the interruption failure caused by the semiconductor branch unavailability is rarely considered. This article proposes a novel MDCCB with N-1 security ability, which is applicable for different numbers of ports and can interrupt faults even when any internal branch is unavailable. The working principles under normal condition and branch unavailability conditions are presented. The fault currents of DC grids are calculated to design the parameters of MDCCB. The feasibility of the proposed topology is validated by a small-scale prototype, and the working performance is further validated by simulations in the DC grid. Compared with existing MDCCBs, the proposed MDCCB combines the characteristics of low investment cost and high reliability, which can ensure the safety and economy of DC grids.