Zhixiang Pan

Zhixiang Pan

Auto-generated profile, based on publicly available information

Zhixiang Pan

Aeronautical Engineering College, Civil Aviation University of China 1 , Tianjin, China

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2024 in Physics of Fluids
Verified
Journal Article
Closed access
PDF file
JWJun Wu
Jun Wu
ZPZhixiang Pan
Zhixiang Pan
CZChenping Zhang
Chenping Zhang
RGRunxia Guo
Runxia Guo
JCJiusheng Chen
Jiusheng Chen
Measurement of the combustion temperature field is an extremely important issue in industrial production. Temperature is one of the key parameters in combustion studies. With the temperature field distribution of the combustion field obtained, heat transfer, heat convection, and heat radiation can be calculated directly and efficiently. Traditional background oriented Schlieren (BOS) is an effective method for non-axisymmetric temperature field measurements, but it requires simultaneous Schlieren imaging at multiple angles for tomographic reconstruction, which will greatly limit its application. In this paper, the compressive sensing algorithm is introduced into the temperature field reconstruction, which establishes the system of equations between the deflection angle and the refractive index gradient. Then, the reconstruction of the non-axisymmetric temperature field is realized by solving the underdetermined system of equations by the method of solving the sparse solution through the compressive sensing. First, light offsets across the non-axisymmetric temperature field are measured by the under-angled BOS system and image processing method. Second, the spatial refractive index field is reconstructed by the compressive sensing BOS method proposed in this paper. Finally, the spatial temperature field is obtained. The experimental results show that by comparing the iRadon reconstruction algorithm and the compressive sensing reconstruction algorithm, the temperature field reconstructed by the compressive sensing under the condition of the under-angled sampling of projection data had a higher accuracy than that reconstructed by the tomographic reconstruction algorithm under the same condition. The average error of the temperature field was reduced from 34.6 to 29.7 K under the same measurement conditions; however, the accuracy is better maintained by using the compressive sensing algorithm under the condition of undersampling projection.

15 January 2024 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
JWJun Wu
Jun Wu
ZPZhixiang Pan
Zhixiang Pan
CZChenping Zhang
Chenping Zhang
RGRunxia Guo
Runxia Guo
XZXIaoyu Zhang
XIaoyu Zhang
JCJiusheng Chen
Jiusheng Chen
As a condition monitoring parameter, the temperature field has a wide range of applications in the field of combustion measurement. As an effective method for noncontact measurement of axisymmetric temperature fields, the traditional background oriented schlieren (BOS) method has a problem of inaccurate calculation of light deflection angles due to the near-optical axis assumption. In this article, the Fan-shaped light path background oriented schlieren (FLBOS) method is introduced into the calculation of the light deflection angle to achieve an accurate reconstruction of the axisymmetric temperature field. First, the offset created by the background scatter across the nonuniform temperature field is measured visually which is used to solve for the light deflection angle based on this offset in the fan light path model. Then the distribution of the spatial refractive index field is solved by the Abel inversion method, which in turn gives the distribution of the spatial temperature field. Finally, the method is verified by simulated experiments on the accuracy and validity of the FLBOS. The experimental results show that the temperature field reconstruction error using FLBOS is decreased by 2.5 percent compared to the conventional BOS and it is applicable to the measurement of a wide range of temperature fields.

18 January 2023 in Measurement Science and Technology
Verified
Journal Article
Closed access
JWJun Wu
Jun Wu
ZPZhixiang Pan
Zhixiang Pan
CZChenping Zhang
Chenping Zhang
FSFengcheng Song
Fengcheng Song
XZXIaoyu Zhang
XIaoyu Zhang
RGRunxia Guo
Runxia Guo
The typical non-axisymmetric temperature field distribution in the tail nozzle outlet area of the combustion chamber of an aircraft engine can reflect the operating state of the engine. As an effective non-contact method for measuring a non-axisymmetric temperature field, the traditional background-oriented schlieren (BOS) method has the problem that the extraction accuracy of light deflection is not high. In this paper, interference fringes are introduced into the schlieren measurement, and the highly sensitive fringe offset replaces the traditional background speckle offset for measurement, which realizes accurate reconstruction of the non-axisymmetric temperature field. Firstly, through the interferometric fringe schlieren (IFS) method comprising multiple sets of double-slit interferometric systems and imaging sensors, the offset of the interference fringe after passing through the non-axisymmetric temperature field is measured by image processing. The spatial refractive index field is then reconstructed by the filtered back-projection algorithm under the sector model proposed in this paper and the spatial temperature field is obtained. The experimental results show that the temperature field reconstruction error is smaller for the IFS method than the BOS method, the measurement area is accurate from 0.5 mm for the BOS method to 0.2 mm for the IFS method and the temperature error range is reduced from 50 K for the BOS method to 25 K for the IFS method.