17 April 2022 in Medical Engineering & Physics
Two working mechanisms of Nasal High-Flow Therapy (NHFT) are washout of anatomical dead space and provision of positive end-expiratory pressure (PEEP). The extent of both mechanisms depends on the respiration aerodynamics and the corresponding pressure distribution: at end-expiration the onset of uniform pressure indicates the jet penetration length, and the level of the uniform pressure is the PEEP. The clinical problem is that adequate measurements in patients are presently impossible. In this study, the respiratory pressure distribution is therefore measured in 3D-printed anatomically correct upper-airway models of an adult and an infant. Assuming that elastic fluctuations in airway anatomy are sufficiently small, the aerodynamics in these rigid models will be very similar to the aerodynamics in patients. It appears that, at end-expiration, the jet penetrates into or slightly beyond the nasal cavity, hardly depending on cannula size or NHFT flow rate. PEEP is approximately proportional to the square of the flow rate: it can be doubled by increasing the flow rate by 40%. In the adult model, PEEP is accurately predicted by the dynamic pressure at the prong-exits, but in the infant model this method fails. During respiration, large pressure fluctuations occur when the cannula is relatively large compared to the nostrils.
16 September 2021 in Medical Engineering & Physics
Spirometry is a gold standard to assess lung function, and to identify respiratory impairments seen in obstructive lung diseases. The method is used for periodic monitoring, but it only provides snapshot information, and it requires forceful exhalation which is associated with limited reliability and repeatability. Several studies indicate that tidal flow-volume curves measured by pneumotachography or plethysmography can also be used to assess lung function. These methods avoid the forced manoeuvre, but are complex to set up or sensitive to movement. In the present work we address the long-standing problem of the unavailability of an easy-to-use and accurate method for monitoring tidal breathing frequently or even continuously. We show that pressure recordings from a nasal cannula can be accurately converted into scaled flow-volume curves by means of an algorithm that continuously calibrates itself. The method has been validated by feeding realistic healthy and unhealthy breathing patterns to anatomically correct 3D-printed upper airways of an infant and an adult, and by comparing the imposed flow-volume curves to the pressure-derived flow-volume curves. The observed very high level of accuracy opens the route towards remotely monitoring patients with chronic lung diseases.
21 October 2021 in Journal of Cardiac Surgery
Background Combining preoperative angiography findings with intraoperative transit time flow measurements (TTFM) may improve patency of coronary artery bypass grafts. Nevertheless, graft flow might be impaired by native coronary flow based on the severity of stenoses, with inferior long-term outcomes. This study investigates the impact of left anterior descending artery (LAD) stenosis on competitive flow measured in left internal mammary artery (LIMA) grafts during off-pump coronary artery bypass grafting. Methods Fifty patients were included in this prospective single-center cohort study. LAD stenosis was assessed with quantitative coronary analysis (QCA) and stratified into three groups based on its severity. TTFM of LIMA grafts were performed with LAD open and temporarily occluded. Change in mean graft flow after LAD snaring was the primary endpoint. Secondary endpoints included further TTFM parameters, clinical outcomes, and competitive flow index (CFI), defined as the ratio of mean graft flow with open or closed LAD. Results Mean LAD stenosis as objectified with QCA was 58 ± 15%. Mean LIMA graft flow increased from 20 ml/min with open LAD to 30 ml/min with snared LAD (p < .001). TTFM cut-off values for graft patency improved in 26%–42% of patients after LAD occlusion. Median CFI was 0.66 (IQR: 0.56–0.82). Postoperative myocardial infarction occurred in 2.0% of patients, 120-day mortality was 0%, and 2-year mortality was 6.0%. Conclusions Routine snaring of the LAD with CFI calculation during coronary artery bypass grafting is useful to detect significant competitive flow in LIMA grafts, potentially preventing unnecessary intraoperative graft revisions.
12 July 2023 in Journal of Fluid Mechanics
Power minimisation of fluid transport in branched fluidic networks has become of paramount importance for microfluidics, additive manufacturing and hierarchical functional materials. For fully developed laminar flow of Newtonian fluids, Murray's theory provides a solution for the channel and network dimensions that minimise power consumption. However, design and optimisation of networks that transport complex fluids is still challenging. Here, we generalise Murray's theory towards fluid rheologies, including non-Newtonian (power-law) and yield-stress fluids (Bingham, Herschel–Bulkley, Casson). A straightforward graphical approach is presented that provides the optimal radii in a branching network, and the angles between these branches. The wall shear stress is found to be uniform over the entire network, and the velocity profile is self-similar. Furthermore, the effect of non-optimal channel radii on the power consumption of the network is investigated. Finally, examples illustrate how this approach applies to a wide variety of systems.
15 May 2025 in Journal of Fluid Mechanics
Power minimisation in branched fluidic networks has gained significant attention in biology and engineering. The optimal network is defined by channel radii that minimise the sum of viscous dissipation and the volumetric energetic cost of the fluid. For limit cases including laminar flows, high-Reynolds-number turbulence or smooth-channel approximations, optimal solutions are known. However, current methods do not allow optimisation for a large intermediate part of the parameter space which is typically encountered in realistic fluidic networks that exhibit turbulent flow. Here, we present a unifying optimisation approach based on the Darcy friction factor, which has been determined for a wide range of flow regimes and fluid models and is applicable to the entire parameter space: (i) laminar and turbulent flows, including networks that exhibit both flow types, (ii) non-Newtonian fluids (powerlaw, Bingham and Herschel–Bulkley) and (iii) networks with arbitrary wall roughness, including non-uniform relative roughness. The optimal channel radii are presented analytically and graphically. All existing limit cases are recovered, and a concise framework is presented for systematic optimisation of fluidic networks. Finally, the parameter $x$ in the optimisation relationship $Q\propto R^{x}$ , with $Q$ the flow rate and $R$ the channel radius, was approximated as a function of the Reynolds number, revealing in which case the entire network can be optimised based on one optimal channel radius, and in which case all radii must be optimised individually. Our approach can be extended to a wide range of fluidic networks for which the friction factor is known, such as different channel curvatures, bubbly flows or specific wall slip conditions.