17 July 2017 in Physical Review A
Efficient cooling of trapped ions is a prerequisite for various applications of the ions in precision spectroscopy, quantum information, and coherence control. Raman sideband cooling is an effective method to cool the ions to their motional ground state. We investigate both numerically and experimentally the optimization of Raman sideband cooling strategies and propose an efficient one, which can simplify the experimental setup as well as reduce the number of cooling pulses. Several cooling schemes are tested and compared through numerical simulations. The simulation result shows that the fixed-width pulses and varied-width pulses have almost the same efficiency for both the first-order and the second-order Raman sideband cooling. The optimized strategy is verified experimentally. A single ion is trapped in a linear Paul trap and Raman sideband cooled, and the achieved average vibrational quantum numbers under different cooling strategies are evaluated. A good agreement between the experimental result and the simulation result is obtained.
1 February 2013 in The European Physical Journal D
An ultra-stable optical reference cavity with re-entrant fused silica mirrors and a ULE (Ultra Low Expansion) spacer structure is designed for the ultranarrow clock laser for an Al+ optical standard. The designed cavity has a low thermal noise limit of 1 × 10-16 and a flexible zero crossing temperature of the effective coefficient of thermal expansion (CTE). The CTE zero crossing temperature difference between a composite cavity and a pure ULE cavity can be tuned from −10°C to 23°C, which enables operation of the designed reference cavity near room temperature without worrying about the CTE zero crossing temperature of the ULE spacer. This design can also be applied to cavities with different lengths. Vibration immunity of the cavity is also achieved through structure optimization.
10 October 2023 in Classical and Quantum Gravity
Many space based gravity missions require frequency stabilized lasers with stringent requirements. Toward those requirements, we develop a compact frequency-stabilized laser which is referenced to the R(56)32−0: a1 transition of molecular iodine based on the modulation transfer spectroscopy technique. The stability of the laser is limited by the beam pointing noise, the electronic servo noise, and the residual amplitude modulation (RAM) noise. To improve the beam pointing stability, the system is constructed by gluing most components of the optical system on an ultra-low expansion glass base. We use a pre-amplifier to suppress the electronic servo noise, and use a wedged electro-optic phase modulator to suppress the RAM noise. The fractional frequency instability of the system is evaluated to be 3.3 × 10−15 at 2 s and 4 s averaging time, and is lower than 6 × 10−15 at averaging times from 1 s to 10 000 s. To our knowledge, this is the best short-term (1–4 s) instability reported so far for an iodine stabilized laser. The stability fully meets the requirements of next generation gravity mission and laser interferometer space antenna mission.
8 April 2024 in Physical Review Applied
Optical clocks have been demonstrated to be good choices to redefine the SI “second.” With this goal, we have constructed a quantum-logic-based ion optical clock with a fractional frequency uncertainty of . A ion is used as the logic ion for sympathetic cooling, state readout, and frequency-shift measurement of the ion. The stability of the optical clock is , measured with a self-comparison method.
6 April 2022 in Journal of Physics B: Atomic, Molecular and Optical Physics
Magnetic field noise is an important factor causing quantum decoherence in quantum systems. In order to suppress the decoherence effect, magnetic field noise needs to be properly measured and controlled. Magnetic field noise power spectrum measurement using a single trapped ion based quantum spectrum analyzer is a very effective way. In this paper, the magnetic field noise measurement based on dynamic decoupling technique is analyzed theoretically. Furthermore, we use magnetically insensitive transition to measure the magnetic field noise, which has the potential to measure stronger magnetic field noise and speed up the measurement process. In our experiment, we suppress the magnetic field noise by using active feedback control and passive compensation, where the required passive compensation amplitude is obtained by measuring the magnetic field noise spectrum of a single 25Mg+ ion. With the magnetic field noise suppressed, the expected contribution of the magnetic field noise to the stability of the 25Mg+–27Al+ ion optical clock can be decreased from to .
21 November 2017 in Physical Review A
We report an experimental determination of the ground-state hyperfine constant of the ions by measuring the to transition (0-0 transition) frequency of the two ground-state hyperfine energy levels. The frequency is measured by rf resonant method in a Paul trap under a magnetic field of about 0.1 mT. The result is 248 7(42) MHz. Different frequency shifts and uncertainties are evaluated. The main effect is quadratic Zeeman shift. Since the Paul trap is driven by rf on the electrodes, ac magnetic field can be induced by the rf at the site of the ion. The ac magnetic field causes quadratic Zeeman shift for ion frequency standards and also reduces the coherence time when the ion acts as a quantum bit. Precision measurement of this ac magnetic field can help evaluating the related uncertainty when a single-ion optical clock is established on the trap.