Stefan Wentaschek

Stefan Wentaschek

Auto-generated profile, based on publicly available information

Stefan Wentaschek

Department of Prosthodontics and Material Science, University Medical Center Mainz, Augustusplatz 2, 55131, Mainz, Germany.

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 December 2014 in Clinical Implant Dentistry and Related Research
Verified
Journal Article
Closed access
PDF file
SWStefan Wentaschek
Stefan Wentaschek
HSHerbert Scheller
Herbert Scheller
ISIrene Schmidtmann
Irene Schmidtmann
SHSinsa Hartmann
Sinsa Hartmann
MWMichael Weyhrauch
Michael Weyhrauch
KLKarl Martin Lehmann
Karl Martin Lehmann

7 October 2022 in Materials
Verified
Journal Article
Open access
PDF file
MBMonika Bjelopavlovic
Monika Bjelopavlovic
MWMichael Weyhrauch
Michael Weyhrauch
HSHerbert Scheller
Herbert Scheller
SWStefan Wentaschek
Stefan Wentaschek
KLKarl Martin Lehmann
Karl Martin Lehmann
Objectives: This study aimed to determine the retentive strength of monolithic hybrid-all-ceramic crowns luted on titanium implant abutments. Material and Methods: In total, 450 crowns (75 each of Mark II, Empress CAD, e.max CAD, Suprinity, Enamic, Celtra Duo) were milled using a CAD/CAM system. The crowns were cemented onto sandblasted titanium implant abutments using five luting agents (Multilink Implant, Variolink II, RelyX Unicem, Fujicem, and Panavia 2.0). After thermocycling was performed (5000 cycles: 5–55 °C, 30-s dwell time), the crowns were removed using a universal testing machine. The location of luting-agent residue on the abutment and inner crown surfaces was evaluated. Analyses of variance (ANOVA) with the Bonferroni correction were performed to evaluate differences of retentive strength depending on the crown material and the kind of the luting agent. Results: The retentive strengths for the different ceramic materials were Vita Mark II: 652N-759N (SD:134N-146N), Empress CAD: 681N-822N (SD: 89N-146N), e.max CAD: 784N-1044N (SD: 109N-176N), Vita Enamic: 716N-1177N (SD: 132N-220N), Vita Suprinity: 867N-1488N (SD: 202N-278N), and Celtra Duo 772N-1335N (SD:151N-229N). After the removal trials, the visual documentation showed different adhesive residue location depending on the ceramic materials. Furthermore, the pull-off force was dependent on the choice of adhesives. No significant differences were found between different luting agents and the ceramic material Vita Mark II and Empress CAD. EmaxCAD showed significant differences with Unicem and FujiCem compared to Panavia, as did VitaSuprinity, VitaEnamic, and Celtra Duo (p < 0.001). Conclusions: The ceramic material used seems to influence the retentive strength and the use of certain luting agents results in a higher retentive strength for some ceramic materials.

25 July 2017 in International Journal of Implant Dentistry
Verified
Journal Article
Open access
PDF file
SWS. Wentaschek
S. Wentaschek
SHS. Hartmann
S. Hartmann
CWC. Walter
C. Walter
WWW. Wagner
W. Wagner
The aim of this retrospective study was to evaluate the treatment outcome of six Bredent blueSky™ implants (Bredent GmbH, Senden, Germany) immediately loaded with a fixed full-arch prosthesis (two tilted posterior and four axial frontal and premolar implants). All 10 patients with atrophic edentulous maxillae being treated with a standardized procedure from 09/2009 to 01/2013, who had a follow-up of at least 3 years, were included. Sixty implants were placed to support 10 screwed prostheses. Twenty-one of them were inserted in fresh extraction sockets. Lab-side-prepared provisional fixed prostheses were placed at the day of implantation. Periotest (PT) values and implant stability quotient (ISQ) were measured after implant surgery and after 3 months of healing in all patients. The analyzed implants were in function in mean 64 ± 13 months (range 42 to 84 months). One axial and two tilted implants failed in three patients. The mean PT values decreased, and ISQ increased significantly after the first 3 months at the osseointegrated tilted and axial implants. With an area under the curve of 0.503 and 0.506 in the receiver operating characteristic, the PT values and the ISQ were unspecific parameters and unsuitable as a predictor for the risk of non-osseointegration. Within the limits of this small group (n = 10 patients/60 implants), the failure rate of the analyzed implant system (n = 3 respective 5% implant loss) seems to be comparable with other immediate-loading protocols. The failure rate of tilted implants in the atrophic upper jaw was quite high, but the aimed treatment concept could be achieved in every patient. The rehabilitation of the posterior region in edentulous maxilla remains a challenge.

1 May 2016 in The International Journal of Prosthodontics
Verified
Journal Article
Closed access
SWStefan Wentaschek
Stefan Wentaschek
KLKarl Martin Lehmann
Karl Martin Lehmann
HSHerbert Scheller
Herbert Scheller
GWGernot Weibrich
Gernot Weibrich
NBNikolaus Behneke
Nikolaus Behneke
Stefan Wentaschek, DMD, MSc/Karl Martin Lehmann, DMD, PhD/Herbert Scheller, DMD, PhD/Gernot Weibrich, MD, DMD, PhD/Nikolaus Behneke, DMD, PhD: Purpose: The aim of this in vitro study was to assess the increase in the polygonal area of implant-retained prosthesis supports in edentulous maxillae with the use of tilted distal implants compared with the use of straight distal implants, using a variety of implant lengths. Materials and Methods: A total of 25 DICOM datasets of atrophic edentulous maxillae were provided. Bone augmentations in the molar region had to be avoided. Two straight reference implants were virtually inserted in the anterior region. Two additional implants were placed far distally on both sides (4 groups: [1] straight, 12-mm length; [2] straight, 10 mm; [3] straight, 8 mm; [4] tilted, 12?16 mm). The resulting implant-supported polygon was measured for each of the 4 groups using three-dimensional planning software. Results: The mean sagittal depth of the supported polygon in Group 1 was 9.9 mm (standard deviation [SD] 4.4) on the right and 10.2 mm (SD 4.4) on the left, and it was 33.7 mm (SD 5.8) in width. For Group 2, the mean sagittal depth was 11.5 mm (SD 5.0) on the right and 11.9 mm (SD 4.7) on the left, and the width was 35.2 mm (SD 5.6). The measurements for Group 3 were 13.8 mm (SD 4.9) deep on the right, 13.8 mm (SD 5.1) deep on the left, and 37.0 mm (SD 5.4) in width. For Group 4, the depth was 15.8 mm (SD 4.9) on the right and 16.4 mm (SD 5.8) on the left, and the width was 39.0 mm (SD 5.1). Conclusion: The area of implant-retained prosthesis support can be enlarged by the use of tilted implants (12 to 16 mm in length, 42 to 45 degrees) compared to the use of straight 8-mm implants (resulting increase: about 15%).

19 May 2021 in Materials
Verified
Journal Article
Open access
PDF file
KLKarl Martin Lehmann
Karl Martin Lehmann
MWMichael Weyhrauch
Michael Weyhrauch
MBMonika Bjelopavlovic
Monika Bjelopavlovic
HSHerbert Scheller
Herbert Scheller
HSHenning Staedt
Henning Staedt
SWStefan Wentaschek
Stefan Wentaschek
Background: CAD/CAM systems enable the production of fixed partial dentures with small and reproducible internal and marginal gaps. Purpose: The purpose of this study was to evaluate the reproducibility of the marginal and internal adaptations of four-unit fixed partial denture frameworks produced using four CAD/CAM systems. Materials and Methods: Prepared dies of a master model that simulated the loss of the first left molar were measured. Fifteen frameworks were manufactured using four CAD/CAM systems (A–D). The internal fit was determined by the replica technique, and the marginal gap was determined by microscopy. ANOVA was carried out to detect significant differences, and the Bonferroni adjustment was performed. The global level of significance was set at 5%. Results: The mean gap size ranged from 84 to 132 µm (SD 43–71 µm). The CAD/CAM systems showed significant variance (p < 0.001), and system A (VHF) showed the smallest gaps. The smallest gaps for each system were in the molar part and in the marginal region of the frameworks (p < 0.001). Conclusions: The CAD/CAM systems showed significantly different gap sizes, particularly between premolars and molars and among the marginal, axial and occlusal regions. All of the systems are suitable for clinical application.

13 February 2017 in Journal of Dentistry and Oral Care
Verified
Journal Article
Open access
PDF file
SWStefan Wentaschek
Stefan Wentaschek
SSSeiß S
Seiß S
ICIgiel C
Igiel C
BNBehneke N
Behneke N