1 July 2021 in KSCE Journal of Civil Engineering
A new type of negative stiffness friction damping device (NSFDD) was developed in this study, which can solve the problem of poor energy dissipation of the existing passive negative stiffness damping device. The friction force is generated by squeezing the friction plate with the preloaded nitrogen spring vertically. When the NSFDD is working, the friction plate causes the nitrogen spring to rotate and negative stiffness force and friction force are generated. The results of the performance test show that the NSFDD can achieve negative stiffness in the hysteretic model. Comparing with the existing negative stiffness device, the NSFDD has larger stroke, more stable negative stiffness and better energy dissipation capacity. The finite element software has been used to simulate the low cycle reciprocation of a structure, and the results show that the NSFDD reduces the stiffness of the structure while increasing the damping of the structure. The results of the simulation and analysis of the shock absorption plan of the NSFDD show that the NSFDD reduces the stiffness of the floor, thereby effectively control on the shear force, displacement and acceleration response of the structure.
1 January 2018 in Advances in Civil Engineering
A parameter optimization design method is proposed for multiple coal bucket dampers (CBDs) to reduce the seismic response of coal‐fired power plants. To test the damping effect of the optimized CBDs, a 1 : 30 scale shaking table test model of a power plant structure was fabricated. A comparative testing program was conducted using three seismic excitations on a model with and without CBDs. A finite element analysis model, replicating the conditions of the shaking table test, was constructed for comparison, and the shock absorption effects of CBDs subjected to 22 groups of far‐field seismic action and 28 groups of near‐field seismic action were analyzed. Finally, the influence of changes in the structural period on the seismic response of the CBD‐equipped structure was studied. The results indicate that the use of CBDs in a coal‐fired power plant structure, based on an optimization design method for multiple‐tuned mass dampers (MTMDs), results in a significant reduction in the structure displacement response, displays a certain discreteness under different excitations, and maintains a certain damping stability even as the structural period changes. Overall, the use of CBDs is a promising prospect for improving the seismic performance of coal‐fired power plant structures.