Thiago Barboza

Thiago Barboza

Auto-generated profile, based on publicly available information

Thiago Barboza

Nuclear Medicine Service, Clementino Fraga Filho University Hospital, Cidade Universitária, Rio de Janeiro, RJ, 21941-913, Brazil

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 August 2018 in Scientific Reports
Verified
Journal Article
Open access
PDF file
APAldo José Fontes Pereira
Aldo José Fontes Pereira
PRPaulo Rosa
Paulo Rosa
TBThiago Barboza
Thiago Barboza
DMDaniel Matusin
Daniel Matusin
AFAline Soares Freire
Aline Soares Freire
WPWagner Coelho De Albuquerque Pereira
Wagner Coelho De Albuquerque Pereira
Bone mineral density is an important parameter for the diagnosis of bone diseases, as well as for predicting fractures and treatment monitoring. Thus, the aim of the present study was to evaluate the potential of Quantitative Ultrasound (QUS) to monitor bone changes after calcium, phosphorus, and magnesium loss in rat femurs in vitro during a demineralization process. Four quantitative ultrasound parameters were estimated from bone surface echoes in eight femur diaphysis of rats. The echo signals were acquired during a decalcification process by Ethylenediaminetetraacetic Acid (EDTA). The results were compared to Quantitative Computed Tomography (QCT) and inductively coupled plasma optical emission spectrometry measurements for validation. Integrated Reflection Coefficient (IRC) reflection parameters and Frequency Slope of Reflection Transfer Function (FSRTF) during demineralization tended to decrease, while the backscattering parameter Apparent Integrated Backscatter (AIB) increased and Frequency Slope of Apparent Backscatter (FSAB) showed an oscillatory behavior with no defined trend. Results indicate a clear relation between demineralization and the corresponding decrease in the reflection parameters and increase in the scattering parameters. The trend analysis of the fall curve of the chemical elements showed a better relationship between IRC and QCT. It was possible to monitor bone changes after ions losses, through the QUS. Thus, it is an indication that the proposed protocol has potential to characterize bone tissue in animal models, providing consistent results towards standardization of bone characterization studies by QUS endorsing its use in humans.

1 August 2018 in Acta Ortopedica Brasileira
Verified
Journal Article
Open access
PDF file
DMDaniel Patterson Matusin
Daniel Patterson Matusin
APAldo José Fontes Pereira
Aldo José Fontes Pereira
PRPaulo Tadeu Cardozo Ribeiro Rosa
Paulo Tadeu Cardozo Ribeiro Rosa
TBThiago Barboza
Thiago Barboza
SSSergio Augusto Lopes de Souza
Sergio Augusto Lopes de Souza
WPWagner Coelho De Albuquerque Pereira
Wagner Coelho De Albuquerque Pereira
Objective: This work evaluates the relationship between ultrasonic reflection and bone density from fourteen cylindrical bovine cortical bone samples (3.0-cm thick). Methods: Twenty US reflection signals per sample were acquired along the bone surface (2.0-mm step). The Integrated Reflection Coefficient (IRC) from each signal was compared to Quantitative Computed Tomography (QCT). Results: Seven IRC and QCT curves presented Pearson's Correlation R-values above 0.5. For weak correlation curves, QCT and IRC showed similar trends in several segments. Conclusion: IRC was sensitive to bone density variation. Level of Evidence: Experimental Study, Investigating a Diagnostic Test.

1 July 2016 in Respiratory Physiology & Neurobiology
Verified
Journal Article
Closed access
MAMariana de Abreu
Mariana de Abreu
ANAlcendino Cândido Neto
Alcendino Cândido Neto
GCGiovanna Carvalho
Giovanna Carvalho
NCNatalia Vasconcelos Casquillo
Natalia Vasconcelos Casquillo
NCNiedja Carvalho
Niedja Carvalho
ACAlysson R. Carvalho
Alysson R. Carvalho