Representative Publications

View All Publications
1 May 2007 in Radiology
Verified
Journal Article
Closed access
EVEliseo Vano
Eliseo Vano
JFJosé Miguel Fernández
José Miguel Fernández
JTJosé Ignacio Ten
José Ignacio Ten
CPCarlos Prieto
Carlos Prieto
LGLuciano González
Luciano González
HHHugo de Las Heras
Hugo de Las Heras
To retrospectively evaluate patient radiation doses in projection radiography after the transition to computed radiography (CR) in the authors' hospital. The hospital's ethical committee approved the study and waived informed consent. In 2001, a dose reduction initiative was implemented, which involved collecting radiographic parameters, calculating patient entrance doses, and monitoring changes with an online computer, and a training program for radiographers was conducted. A database with 204 660 patient dose values was used to compute changes in patient doses over time. Sample sizes ranged from 1800 to 23 000 examinations. Doses were compared with European and American reference values. Kruskal-Wallis and Mann-Whitney tests were used for statistical analysis. Median values for patient entrance doses increased 40%-103% after implementation of CR. Initial increases were corrected during the 1st year, and additional dose decreases were achieved after the dose reduction initiative was launched. At present, doses range between 15% and 38% of the European diagnostic reference levels established for screen-film radiography and between 28% and 41% of the reference values recommended by the American Association of Physicists in Medicine, representing an effective 20%-50% reduction in the initial values for CR. Though patient doses can increase considerably during the transition from conventional screen-film radiography to CR, dose management programs, including specific training of radiographers and patient dose audits, allow for reductions of the previous values.

1 August 2004 in JACC
Verified
Journal Article
Closed access
MTManel Sabaté Tenas
Manel Sabaté Tenas
GPGela Pimentel
Gela Pimentel
CPCarlos Prieto
Carlos Prieto
JCJosé María Corral
José María Corral
CBCamino Bañuelos
Camino Bañuelos
CMCarlos Macaya
Carlos Macaya

1 December 2005 in Radiation Protection Dosimetry
Verified
Journal Article
Closed access
PDF file
EVEliseo Vano
Eliseo Vano
LGL. Gonzalez
L. Gonzalez
EGE. Guibelalde
E. Guibelalde
PAP. Aviles
P. Aviles
JFJ. M. Fernandez
J. M. Fernandez
CGC. Galvan
C. Galvan
A methodology for the evaluation of skin dose distribution and possible skin injuries on patients undergoing interventional procedures has been developed as part of the European DIMOND programme. Relevant dosimetric data from the procedures are recorded and other specific measurements for skin dose evaluation (slow films for therapy, radiochromic films, thermoluminescence dosemeters and optically stimulated luminescence dosemeters) have been carried out. For non-cardiac and for some cardiac procedures, dose–area product values of 200 and 300 Gy cm2 were proposed, respectively, as a trigger level for further detailed skin dose investigation and possible clinical follow-up. Results from a survey of 191 selected complex procedures are reported. Out of all the patients included in the trial, 16% received skin doses ≥1.5 Gy. No skin injuries were found in any of the patients followed.

23 March 2006 in Journal of Cardiovascular Electrophysiology
Verified
Journal Article
Closed access
PDF file
NPNicasio Pérez‐Castellano
Nicasio Pérez‐Castellano
JVJulián Villacastín
Julián Villacastín
PAPaloma Aragoncillo
Paloma Aragoncillo
PFPanayotis Fantidis
Panayotis Fantidis
MTManel Sabaté Tenas
Manel Sabaté Tenas
CMCarlos Macaya
Carlos Macaya

17 June 2004 in Medical Physics
Verified
Journal Article
Closed access
POPedro M. Ortego
Pedro M. Ortego
CPCarlos Prieto
Carlos Prieto
EVEliseo Vano
Eliseo Vano

17 July 2009 in Radiation Protection Dosimetry
Verified
Journal Article
Closed access
PDF file
EVEliseo Vano
Eliseo Vano
CUCarlos Ubeda
Carlos Ubeda
JFJose Miguel Fernandez
Jose Miguel Fernandez
RSRoberto M. Sanchez
Roberto M. Sanchez
CPCarlos Prieto
Carlos Prieto
Incident air kerma (IAK) and entrance surface air kerma (ESAK) have been measured for a range of copper (Cu) absorbers (1–10 mm) and polymethylmethacrylate (PMMA) slabs (12–28 cm) with kilovolt values ranging from 61 to 120 during the commissioning of an X-ray system equipped with a flat detector used in interventional cardiology procedures. Numerical parameters on image quality have also been measured for different X-ray beam qualities using the plastic wall of the ionisation chamber. When moving from 1 to 10 mm of Cu, IAK per frame increased to a factor of 38 for cine and 27 for fluoroscopy. A cine frame requires 60–116 times more IAK than a fluoroscopy frame. As for PMMA, when the backscatter factor is included (simulating real conditions with patients), and when moving from 12 to 28 cm, the increases in ESAK are 16 times for cine and 10 times for fluoroscopy. Because of the differences in X-ray beam quality for cine and fluoroscopy modes, the Cu thicknesses necessary to drive the generator to equivalent kilovolts resulted in the following values (cine and fluoroscopy, respectively): 12 cm of PMMA (1 and 1.5 mm Cu), 20 PMMA (2.5 and 3.5 mm Cu) and 28 cm PMMA (4.5 and 8.5 mm Cu). With the analysis of IAK, ESAK and image quality, one can verify the appropriate settings of the X-ray system and obtain baseline information for constancy checks and help cardiologists in the management of patient doses by knowing the dose increase factors and image quality changes when increasing patient thickness or using different C-arm projections.