17 January 2020 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Cavitation events generated during histotripsy therapy generate large acoustic cavitation emission (ACE) signals that can be detected through the skull. This article investigates the feasibility of using these ACE signals, acquired using the elements of a 500-kHz, 256-element hemispherical histotripsy transducer as receivers, to localize and map the cavitation activity in real time through the human skullcap during transcranial histotripsy therapy. The locations of the generated cavitation events predicted using the ACE feedback signals in this study were found to be accurate to within <1.5 mm of the centers of masses detected by optical imaging and found to lie to within the measured volumes of the generated cavitation events in $ {\gtrsim 80}$ % of cases. Localization results were observed to be biased in the prefocal direction of the histotripsy array and toward its transverse origin but were only weakly affected by focal steering location. The choice of skullcap and treatment pulse repetition frequency (PRF) were both observed to affect the accuracy of the localization results in the low PRF regime (1–10 Hz), but the localization accuracy was seen to stabilize at higher PRFs (≥10 Hz). Tests of the localization algorithm in vitro , for treatment delivered to a bovine brain sample mounted within the skullcap, revealed good agreement between the ACE feedback-generated treatment map and the morphological characteristics of the treated volume of the brain sample. Localization during experiments was achieved in real time for pulses delivered at rates up to 70 Hz, but benchmark tests indicate that the localization algorithm is scalable, indicating that higher rates are possible with more powerful hardware. The results of this article demonstrate the feasibility of using ACE feedback signals to localize and map transcranially generated cavitation events during histotripsy. Such capability has the potential to greatly simplify transcranial histotripsy treatments, as it may provide a non-MRI-based method for monitoring and localizing transcranial histotripsy treatments in real time.
23 July 2018 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Residual bubbles produced after collapse of a cavitation cloud provide cavitation nuclei for subsequent cavitation events, causing cavitation to occur repeatedly at the same discrete set of sites. This effect, referred to as cavitation memory, limits the efficiency of histotripsy soft tissue fractionation. Besides passively mitigating cavitation memory by using a low pulse repetition frequency (~ 1 Hz), an active strategy was developed by our group. In this strategy, low-amplitude ultrasound sequences were used to stimulate coalescence of residual bubbles. The goal of this work is to remove cavitation memory and achieve rapid, homogeneous lesion formation using a single phased array transducer. A 1 MHz integrated histotripsy and bubble coalescing (HBC) transducer system with a specialized electronic driving system was built in house. High amplitude (P- >= 30 MPa) histotripsy pulses and subsequent low amplitude (~1-2 MPa) bubble coalescing (BC) sequences were applied to a red blood cell (RBC) tissue-mimicking phantom at a single focal site. Significant reduction of the cavitation memory effect and increase in the fractionation rate were observed by introducing BC sequence. Effects of BC pulsing parameters were further studied. The optimal BC parameters were then utilized to homogenize a 10 × 10 mm region at high rate.
26 May 2022 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
A novel method for fabricating a modular, kerf-minimizing histotripsy phased array was developed and tested. The method utilizes arbitrarily shaped elements, 3-D printing, water jet cutting, and a thin, 125- $\mu \text{m}$ electrically insulating epoxy coating to maximize aperture utilization while allowing for replacement of individual transducer modules. The method was used to fabricate a 750-kHz truncated circular aperture array (165 mm $\times234$ mm) transducer with a focal length of 142 mm. The aperture was segmented into 260 arc-shaped modular elements, each approximately 11.5 mm $\times11.5$ mm, arranged in concentric rings. The resulting aperture utilization was 92%. The full-width-half-maximum (FWHM) focal zone of the array was measured to be 1.6 mm $\times1.1$ mm $\times4.5$ mm, and the FWHM electrical steering range was measured to be 38.5 mm $\times33$ mm $\times \,\,>$ 40 mm. The array was estimated to be capable of generating approximately 120-MPa peak negative pressure at the geometric focus. In addition, the array was used to ablate a 5-cm3 volume of tissue with electric focal steering.