U-Ryeong Chung

U-Ryeong Chung

Auto-generated profile, based on publicly available information

U-Ryeong Chung

Department of Korean Internal Medicine, Dongguk University Bundang Oriental Hospital

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2022 in Journal of Korean Medicine
Verified
Journal Article
Open access
PDF file
HJHansol Jang
Hansol Jang
UCU-Ryeong Chung
U-Ryeong Chung
JMJeong-Hyun Moon
Jeong-Hyun Moon
SCSeong-Kyeong Choi
Seong-Kyeong Choi
WSWon-Suk Sung
Won-Suk Sung
EKEun-Jung Kim
Eun-Jung Kim
Objectives: This research aimed to develop a guideline for evaluating safety and performance of electronic warm-acupuncture apparatus. With the development of medical devices like electronic warm-acupuncture apparatus with improved performance, convenience and safety measures compared to traditional warm-acupuncture needling, safety and performance guideline is a necessity.Methods: By referring to existing standards and guidelines of other electronic devices for Korean medicine with heating function, guideline for safety and performance assessment of electronic warm-acupuncture apparatus was draftedResults: The guideline, presents explanation for adequate temperature and settings of the apparatus, and safety measurements providing against thermal runaway situations along with guidelines for the manual. Guideline for detailed test method for the performance of the apparatus such as accuracy of temperature increase and the timer, and safety unit was also provided. The test items and suggested test methods for the requirements of biological, electrical and electromagnetic safety were referred to Korean approval documents of ministry of Food and Drug Safety.Conclusion: We proposed the relevant items to verify performance and safety of warm-acupuncture apparatus to assure patient safety and improve the quality of currently developing devices for application in clinical field.

27 December 2023 in Korean Journal of Acupuncture
Verified
Journal Article
Open access
PDF file
JLJa-Ha Lee
Ja-Ha Lee
JMJeong-Hyun Moon
Jeong-Hyun Moon
UCU-Ryeong Chung
U-Ryeong Chung
SHSoo-Hwa Hong
Soo-Hwa Hong
GPGyoungeun Park
Gyoungeun Park
EKEun-Jung Kim
Eun-Jung Kim
Ja-Ha Lee, Jeong-Hyun Moon, U-Ryeong Chung, Soo-Hwa Hong, Gyoungeun Park, Byung Wook Lee, Won-Suk Sung, Jong-Hwa Yoon, Eun-Jung Kim. Korean J Acupunct 2023;40:184-93. https://doi.org/10.14406/acu.2023.022

1 March 2023 in Journal of Korean Medicine
Verified
Journal Article
Open access
PDF file
HJHansol Jang
Hansol Jang
UCU-Ryeong Chung
U-Ryeong Chung
JMJeong-Hyun Moon
Jeong-Hyun Moon
SCSeong-Kyeong Choi
Seong-Kyeong Choi
WSWon-Suk Sung
Won-Suk Sung
EKEun-Jung Kim
Eun-Jung Kim
Objectives: This research aimed to develop a guideline for evaluating safety and performance of electronic warm-acupuncture apparatus. With the development of medical devices like electronic warm-acupuncture apparatus with improved performance, convenience and safety measures compared to traditional warm-acupuncture needling, safety and performance guideline is a necessity.Methods: By referring to existing standards and guidelines of other electronic devices for Korean medicine with heating function, guideline for safety and performance assessment of electronic warm-acupuncture apparatus was draftedResults: The guideline, presents explanation for adequate temperature and settings of the apparatus, and safety measurements providing against thermal runaway situations along with guidelines for the manual. Guideline for detailed test method for the performance of the apparatus such as accuracy of temperature increase and the timer, and safety unit was also provided. The test items and suggested test methods for the requirements of biological, electrical and electromagnetic safety were referred to Korean approval documents of ministry of Food and Drug Safety.Conclusion: We proposed the relevant items to verify performance and safety of warm-acupuncture apparatus to assure patient safety and improve the quality of currently developing devices for application in clinical field.