Yoshitaka Bito

Yoshitaka Bito

Auto-generated profile, based on publicly available information

Yoshitaka Bito

Department of Diagnostic Imaging, Faculty of Medicine Hokkaido University Sapporo Hokkaido Japan

Research Focus & Metrics

Academic Career Length

33Years (1994-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2022 in RadioGraphics
Verified
Journal Article
Closed access
THTaisuke Harada
Taisuke Harada
KKKohsuke Kudo
Kohsuke Kudo
NFNoriyuki Fujima
Noriyuki Fujima
MYMasato Yoshikawa
Masato Yoshikawa
YIYohei Ikebe
Yohei Ikebe
MMMari Miyata
Mari Miyata
Quantitative susceptibility mapping (QSM) is an advanced MRI technique for evaluating the distribution of magnetic susceptibility related to substances such as iron, hemosiderin, and deoxyhemoglobi... Quantitative susceptibility mapping (QSM), one of the advanced MRI techniques for evaluating magnetic susceptibility, offers precise quantitative measurements of spatial distributions of magnetic s...

23 April 2021 in Magnetic Resonance in Medicine
Verified
Journal Article
Closed access
PDF file
YBYoshitaka Bito
Yoshitaka Bito
KHKuniaki Harada
Kuniaki Harada
HOHisaaki Ochi
Hisaaki Ochi
KKKohsuke Kudo
Kohsuke Kudo

1 January 2016 in Magnetic Resonance in Medical Sciences
Verified
Journal Article
Closed access
SYSuguru Yokosawa
Suguru Yokosawa
MSMakoto Sasaki
Makoto Sasaki
YBYoshitaka Bito
Yoshitaka Bito
KIKenji Ito
Kenji Ito
FYFumio Yamashita
Fumio Yamashita
KKKohsuke Kudo
Kohsuke Kudo
To shorten acquisition of diffusion kurtosis imaging (DKI) in 1.5-tesla magnetic resonance (MR) imaging, we investigated the effects of the number of b-values, diffusion direction, and number of signal averages (NSA) on the accuracy of DKI metrics. We obtained 2 image datasets with 30 gradient directions, 6 b-values up to 2500 s/mm(2), and 2 signal averages from 5 healthy volunteers and generated DKI metrics, i.e., mean, axial, and radial kurtosis (MK, K∥, and K⊥) maps, from various combinations of the datasets. These maps were estimated by using the intraclass correlation coefficient (ICC) with those from the full datasets. The MK and K⊥ maps generated from the datasets including only the b-value of 2500 s/mm(2) showed excellent agreement (ICC, 0.96 to 0.99). Under the same acquisition time and diffusion directions, agreement was better of MK, K∥, and K⊥ maps obtained with 3 b-values (0, 1000, and 2500 s/mm(2)) and 4 signal averages than maps obtained with any other combination of numbers of b-value and varied NSA. Good agreement (ICC > 0.6) required at least 20 diffusion directions in all the metrics. MK and K⊥ maps with ICC greater than 0.95 can be obtained at 1.5T within 10 min (b-value = 0, 1000, and 2500 s/mm(2); 20 diffusion directions; 4 signal averages; slice thickness, 6 mm with no interslice gap; number of slices, 12).

1 January 2017 in Magnetic Resonance in Medical Sciences
Verified
Journal Article
Open access
RSRyota Satoh
Ryota Satoh
TSToru Shirai
Toru Shirai
YTYo Taniguchi
Yo Taniguchi
TMTakenori Murase
Takenori Murase
YBYoshitaka Bito
Yoshitaka Bito
HOHisaaki Ochi
Hisaaki Ochi
Quantitative susceptibility mapping (QSM) is a new magnetic resonance imaging (MRI) technique for noninvasively estimating the magnetic susceptibility of biological tissue. Several methods for QSM have been proposed. One of these methods can estimate susceptibility with high accuracy in tissues whose contrast is consistent between magnitude images and susceptibility maps, such as deep gray-matter nuclei. However, the susceptibility of small veins is underestimated and not well depicted by using the above approach, because the contrast of small veins is inconsistent between a magnitude image and a susceptibility map. In order to improve the estimation accuracy and visibility of small veins without streaking artifacts, a method with multiple dipole-inversion combination with k-space segmentation (MUDICK) has been proposed. In the proposed method, k-space was divided into three domains (low-frequency, magic-angle, and high-frequency). The k-space data in low-frequency and magic-angle domains were obtained by L1-norm regularization using structural information of a pre-estimated susceptibility map. The k-space data in high-frequency domain were obtained from the pre-estimated susceptibility map in order to preserve small-vein contrasts. Using numerical simulation and human brain study at 3 Tesla, streaking artifacts and small-vein susceptibility were compared between MUDICK and conventional methods (MEDI and TKD). The numerical simulation and human brain study showed that MUDICK and MEDI had no severe streaking artifacts and MUDICK showed higher contrast and accuracy of susceptibility in small-veins compared to MEDI. These results suggest that MUDICK can improve the accuracy and visibility of susceptibility in small-veins without severe streaking artifacts.

1 January 1995 in Magnetic Resonance in Medicine
Verified
Journal Article
Closed access
PDF file
YBYoshitaka Bito
Yoshitaka Bito
SHSatoshi Hirata
Satoshi Hirata
TNTakayuki Nabeshima
Takayuki Nabeshima
EYEtsuji Yamamoto
Etsuji Yamamoto

30 April 2022 in Journal of Magnetic Resonance Imaging
Verified
Journal Article
Closed access
THTaisuke Harada
Taisuke Harada
KKKohsuke Kudo
Kohsuke Kudo
HKHiroyuki Kameda
Hiroyuki Kameda
RSRyota Sato
Ryota Sato
TSToru Shirai
Toru Shirai
MSMakoto Sasaki
Makoto Sasaki