Biting Ma

Biting Ma

Auto-generated profile, based on publicly available information

Biting Ma

The Tianjin Key Laboratory of Intelligent Robotic (tjKLIR), Institute of Robotics and Automatic Information System (IRAIS), Nankai University, Tianjin, China

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 July 2024 in IEEE Transactions on Automation Science and Engineering
Verified
Journal Article
Closed access
RLRuimin Li
Ruimin Li
MLMinghui Li
Minghui Li
JQJinyu Qiu
Jinyu Qiu
KLKe Li
Ke Li
YLYuzhu Liu
Yuzhu Liu
QZQili Zhao
Qili Zhao
Polar body biopsy has been widely applied in preimplantation genetic diagnosis for assisted reproductive technology. The key step in the polar body biopsy is picking up the polar body from the oocyte/embryo using a micropipette. Unfortunately, the almost transparent appearance of the polar body as well as its dynamic drift when the micropipette approaches it inside the cell makes it a challenging task to pick it up with less cytoplasm loss for the cell. The unnecessary cytoplasm loss in the picking up process of the polar body easily causes damage to the development competence of the cell and may lead to disturbances to the biopsy results of the polar body. This paper proposes a precise robotic picking up method of polar bodies with less cytoplasm loss for biopsy purposes. First, a defocus imaging method is proposed to locate the polar body with an almost transparent appearance. Then, the dynamic drift of the polar body with the micropipette moving inside the cell is modeled online based on force analysis to determine an appropriate trajectory for the micropipette to approach the polar body. Further, an Active Disturbance Rejection Controller (ADRC) is designed to move the micropipette along the desired trajectory to approach the polar body and then aspirate it into the micropipette. The experimental results on porcine oocytes demonstrate that our system is capable of localizing the polar body with a success rate of 95 $\%$ and an average error of 1.12 $\pm$ 0.14 $\mu$ m. Moving along the determined trajectory, the micropipette is capable of approaching the edge of the polar body with an average error of 1.84 $\pm$ 0.31 $\mu$ m (n $=$ 20), which is only 11 $\%$ of the results obtained without dynamic drift estimation of the polar body. With this advantage, our system picks up the polar body with a close 60 $\%$ improvement in success rate (95 $\%$ vs 60 $\%$ ) and only half of the average cytoplasm loss (5 $\%$ vs 10 $\%$ ) in comparison to operation results without dynamic drift estimation. Note to Practitioners —Picking up of polar body from the oocyte/embryo using a micropipette is a vital operation in the polar body biopsy. Precisely picking up the polar body with less cytoplasm is vital to maintaining the developmental competence of the embryo/oocyte and reducing disturbances to biopsy result. This article presented a precise robotic picking up process of polar body. This process introduced defocus imaging method for polar body localization, dynamic drift estimation of polar body, and micropipette trajectory design and motion control by Active Disturbance Rejection Controller (ADRC). Experimental results have demonstrated the efficiency of the proposed robotic picking up process. Application of this process may provide an economical and practical method to carry polar body biopsy for practitioners.

1 July 2024 in IEEE Transactions on Automation Science and Engineering
Verified
Journal Article
Closed access
CCChaoyu Cui
Chaoyu Cui
RLRuimin Li
Ruimin Li
SFShaojie Fu
Shaojie Fu
SXShiyu Xu
Shiyu Xu
BMBiting Ma
Biting Ma
QZQili Zhao
Qili Zhao
In recent years, the perforated patch clamp technique has been widely applied in cellular electrophysiology research due to its low mechanical disturbance and almost no loss of cellular content in cell membrane perforation process. However, the current passive release process of perforating materials prolongs the perforation process and easily disturbs the gigaseal formation process, significantly lowering the efficiency of perforated patch clamp operation. Addressing this, a robotic perforated patch clamp system was developed based on the active release control of perforating materials in this paper. First, a novel holding module of the patch micropipette integrated with an independently driven transmission channel of the perforating materials was developed for the first time. Then, through release tests of the perforating materials, the appropriate drive mode of transmission channel was determined to be the hydraulic mode with a faster response and higher stability. Further, the concentration gradient field of the perforating materials at the opening of the channel was modeled according to Fick’s law to prevent the false release of them in gigaseal formation process. Furthermore, a cell circuit model was developed to detect perforation degree online for feedback control of the perforating materials release. Experimental results on pyramidal neurons in mouse brain slices demonstrated that, in comparison to the traditional method with passive releases of perforating materials, the proposed system was capable of perforating cell membrane at an almost doubled throughput and with a 57% improvement in the success rate. In comparison to the traditional non-perforated whole-cell patch clamp method, the signal recording duration of neurons operated by our method was doubled due to its fewer negative influences on gigaseal and almost no cellular content loss. Note to Practitioners —The perforated patch clamp technique, utilizes the cell membrane-perforating molecules to drill subnanometer-sized conductive pores in the cell membrane aspirated into a micropipette for the measurement of cellular electrophysiological signals. Unfortunately, the poor controllability of the current passive release of perforating materials in the patch clamp operation easily leads to a long drug diffusion process, and also, disturbs the gigaseal formation between the aspirated cell membrane and micropipette, which is required for the measurement of the extremely weak cellular electrophysiological signals. For the first time, an active release control method of perforating materials was developed in this paper based on the self-developed novel three-channel holding device. With active release control of perforating materials, the proposed method was capable of perforating cell membranes at a doubled speed with a significantly higher success rate, and doubled recording duration in comparison to the traditional perforated patch clamp methods and non-perforated whole-cell patch clamp method, respectively, due to its fewer negative influences on gigaseal and almost no cellular content loss. With the above advantages, our robotic perforated patch clamp method may be applied in cellular electrophysiology research in the future.