Olof Svensson

Olof Svensson

Auto-generated profile, based on publicly available information

Olof Svensson

European Synchrotron Radiation Facility, BP 220, 38043 Grenoble, France

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 October 2009 in Journal of Synchrotron Radiation
Verified
Journal Article
Closed access
PDF file
MIMarie-Françoise Incardona
Marie-Françoise Incardona
GBGleb P. Bourenkov
Gleb P. Bourenkov
KLKarl Levik
Karl Levik
RPRomeu A. Pieritz
Romeu A. Pieritz
APAlexander N. Popov
Alexander N. Popov
OSOlof Svensson
Olof Svensson

18 March 2005 in Review of Scientific Instruments
Verified
Journal Article
Closed access
PDF file
MMMarco Di Michiel
Marco Di Michiel
JMJose Manuel Merino
Jose Manuel Merino
DFDavid Fernandez-Carreiras
David Fernandez-Carreiras
TBThomas Buslaps
Thomas Buslaps
VHVeijo Honkimäki
Veijo Honkimäki
OSOlof Svensson
Olof Svensson
At the High Energy Beamline ID15A at the European Synchrotron Radiation Facility we have developed a fast three-dimensional x-ray microtomography system, which acquires a complete dataset in typically less than 10s . This unprecedented speed is achieved by combining a high efficiency phosphor screen, a reflecting microscope objective and a fast charge coupled device detector with the very intense high-energy white beam radiation provided by a wiggler source. The achieved spatial resolution is 2μm . The available x-ray energy spectrum spans from 20to250keV and can therefore be used for low and high Z materials. The spectrum can be modified by inserting different filters into the x-ray beam in order to optimize the signal-to-noise ratio and to avoid beam-hardening artifacts. Different phosphors with different energy sensitivity can be used. The very high speed allows in situ studies of systems evolving on the time scale of a few seconds or minutes. Three examples are given on sintering of metallic powders, solidification of binary alloys and liquid front propagation in granular materials.

28 May 2019 in Acta Crystallographica Section D Structural Biology
Verified
Journal Article
Open access
PDF file
EKEaazhisai Kandiah
Eaazhisai Kandiah
TGThierry Giraud
Thierry Giraud
AAAlejandro de Maria Antolinos
Alejandro de Maria Antolinos
FDFabien Dobias
Fabien Dobias
GEGrégory Effantin
Grégory Effantin
CMChristoph Mueller-Dieckmann
Christoph Mueller-Dieckmann
Recent improvements in direct electron detectors, microscope technology and software provided the stimulus for a `quantum leap' in the application of cryo-electron microscopy in structural biology, and many national and international centres have since been created in order to exploit this. Here, a new facility for cryo-electron microscopy focused on single-particle reconstruction of biological macromolecules that has been commissioned at the European Synchrotron Radiation Facility (ESRF) is presented. The facility is operated by a consortium of institutes co-located on the European Photon and Neutron Campus and is managed in a similar fashion to a synchrotron X-ray beamline. It has been open to the ESRF structural biology user community since November 2017 and will remain open during the 2019 ESRF–EBS shutdown.

31 October 2015 in Acta Crystallographica Section D Structural Biology
Verified
Journal Article
Open access
PDF file
UZUlrich Zander
Ulrich Zander
GBGleb Bourenkov
Gleb Bourenkov
APAlexander N. Popov
Alexander N. Popov
DSDaniele de Sanctis
Daniele de Sanctis
OSOlof Svensson
Olof Svensson
GLGordon A. Leonard
Gordon A. Leonard
Here, an automated procedure is described to identify the positions of many cryocooled crystals mounted on the same sample holder, to rapidly predict and rank their relative diffraction strengths and to collect partial X-ray diffraction data sets from as many of the crystals as desired. Subsequent hierarchical cluster analysis then allows the best combination of partial data sets, optimizing the quality of the final data set obtained. The results of applying the method developed to various systems and scenarios including the compilation of a complete data set from tiny crystals of the membrane protein bacteriorhodopsin and the collection of data sets for successful structure determination using the single-wavelength anomalous dispersion technique are also presented.

27 June 2018 in Journal of Synchrotron Radiation
Verified
Journal Article
Open access
PDF file
AMAndrew Aloysius Mccarthy
Andrew Aloysius Mccarthy
RBRay Barrett
Ray Barrett
ABAntonia Beteva
Antonia Beteva
HCHugo Caserotto
Hugo Caserotto
FDFabien Dobias
Fabien Dobias
CMChristoph Mueller-Dieckmann
Christoph Mueller-Dieckmann
ID30B is an undulator-based high-intensity, energy-tuneable (6.0–20 keV) and variable-focus (20–200 µm in diameter) macromolecular crystallography (MX) beamline at the ESRF. It was the last of the ESRF Structural Biology Group's beamlines to be constructed and commissioned as part of the ESRF's Phase I Upgrade Program and has been in user operation since June 2015. Both a modified microdiffractometer (MD2S) incorporating an in situ plate screening capability and a new flexible sample changer (the FlexHCD) were specifically developed for ID30B. Here, the authors provide the current beamline characteristics and detail how different types of MX experiments can be performed on ID30B (http://www.esrf.eu/id30b).

29 April 2020 in Journal of Synchrotron Radiation
Verified
Journal Article
Open access
PDF file
DSDavid von Stetten
David von Stetten
PCphilippe carpentier
philippe carpentier
DFDavid Flot
David Flot
ABAntonia Beteva
Antonia Beteva
HCHugo Caserotto
Hugo Caserotto
CMChristoph Mueller-Dieckmann
Christoph Mueller-Dieckmann
ID30A-3 (or MASSIF-3) is a mini-focus (beam size 18 µm × 14 µm) highly intense (2.0 × 1013 photons s−1), fixed-energy (12.81 keV) beamline for macromolecular crystallography (MX) experiments at the European Synchrotron Radiation Facility (ESRF). MASSIF-3 is one of two fixed-energy beamlines sited on the first branch of the canted undulator setup on the ESRF ID30 port and is equipped with a MD2 micro-diffractometer, a Flex HCD sample changer, and an Eiger X 4M fast hybrid photon-counting detector. MASSIF-3 is recommended for collecting diffraction data from single small crystals (≤15 µm in one dimension) or for experiments using serial methods. The end-station has been in full user operation since December 2014, and here its current characteristics and capabilities are described.