Phattanun Thabarsa

Phattanun Thabarsa

Auto-generated profile, based on publicly available information

Phattanun Thabarsa

Bio-Inspired Robotics and Neural Engineering Laboratory (BRAIN Lab)-INTERFACES, School of Information Science and Technology (IST), Vidyasirimedhi Institute of Science and Technology (VISTEC), Rayong, Thailand

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 April 2026 in IEEE Sensors Journal
Verified
Journal Article
Closed access
SSSuvichak Santiwongkarn
Suvichak Santiwongkarn
CHChatdanai Hutchaleelaha
Chatdanai Hutchaleelaha
TCTanut Chokchatchawathi
Tanut Chokchatchawathi
PAPhairot Autthasan
Phairot Autthasan
TKThitikorn Kaewlee
Thitikorn Kaewlee
TWTheerawit Wilaiprasitporn
Theerawit Wilaiprasitporn
Wireless wearable devices enable convenient acquisition of photoplethysmograph signals. A limitation of continual measurement is the resource-constrained processing and limited battery capacity. To solve the transmission power consumption problem, we propose an information reduction method, AutoPPGEncoder. The AutoPPGEncoder is an autoencoder trained with conventional MSE loss and MSE systolic peak amplitude loss. The scheduling of impact from two losses improves the raw signal reconstruction by preserving the systolic peak in the reconstructed signal. Our system reduces the amount of transmitted BLE data from the PPG data by a ratio of 1:7.07. In terms of signal quality, the AutoPPGEncoder performs better than the recent compression technique, DCSNET compression in both Percentage Root-mean-square Difference (PRD) and peak amplitude PRD on BIDMC, SensAI, and VitalDB datasets. The AutoPPGEncoder’s power consumption was verified on an NRF54L15-DK board, reduced the total energy consumption by 0.4 mJ per segment. This demonstrated the capability of the AutoPPGEncoder in IoT applications with power efficiency and the quality of PPG signal transmission.

11 December 2025 in JMIR Formative Research
Verified
Journal Article
Open access
SASalita Angkurawaranon
Salita Angkurawaranon
NJNatipat Jitmahawong
Natipat Jitmahawong
KUKittisak Unsrisong
Kittisak Unsrisong
PTPhattanun Thabarsa
Phattanun Thabarsa
CMChakri Madla
Chakri Madla
PIPapangkorn Inkeaw
Papangkorn Inkeaw
Background: Early identification of the etiology of spontaneous intracerebral hemorrhage (ICH) could significantly contribute to planning a suitable treatment strategy. A notable radiomics-based artificial intelligence (AI) model for classifying causes of spontaneous ICH from brain computed tomography scans has been previously proposed. Objective: This study aimed to externally validate and assess the utility of this AI model. Methods: This study used 69 computed tomography scans from a separate cohort to evaluate the AI model’s performance in classifying nontraumatic ICHs into primary, tumorous, and vascular malformation related. We also assessed the accuracy, sensitivity, specificity, and positive predictive value of clinicians, radiologists, and trainees in identifying the ICH causes before and after using the model’s assistance. The performances were statistically analyzed by specialty and expertise levels. Results: The AI model achieved an overall accuracy of 0.65 in classifying the 3 causes of ICH. The model’s assistance improved overall diagnostic performance, narrowing the gap between nonradiology and radiology groups, as well as between trainees and experts. The accuracy increased from 0.68 to 0.72, from 0.72 to 0.76, from 0.69 to 0.74, and from 0.72 to 0.75 for nonradiologists, radiologists, trainees, and specialists, respectively. With the model’s support, radiology professionals demonstrated the highest accuracy, highlighting the model’s potential to enhance diagnostic consistency across different levels. Conclusions: When applied to an external dataset, the accuracy of the AI model in categorizing spontaneous ICHs based on radiomics decreased. However, using the model as an assistant substantially improved the performance of all reader groups, including trainees and radiology and nonradiology specialists.

15 May 2026 in IEEE Sensors Journal
Verified
Journal Article
Closed access
WPWipamas Polpakdee
Wipamas Polpakdee
PAPhairot Autthasan
Phairot Autthasan
RCRattanaphon Chaisaen
Rattanaphon Chaisaen
PTPhattanun Thabarsa
Phattanun Thabarsa
SKSupavit Kongwudhikunakorn
Supavit Kongwudhikunakorn
WSWanumaidah Saengmolee
Wanumaidah Saengmolee