Thomas Holmark

Thomas Holmark

Auto-generated profile, based on publicly available information

Thomas Holmark

University of Amsterdam

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 June 2025 in Analytical Chemistry
Verified
Journal Article
Open access
ZZZiran Zhai
Ziran Zhai
THThomas Holmark
Thomas Holmark
AZAnnika A. M. van der Zon
Annika A. M. van der Zon
VTVasilis Tseliou
Vasilis Tseliou
FMFrancesco Mutti
Francesco Mutti
AGAndrea F.G. Gargano
Andrea F.G. Gargano
Native size-exclusion chromatography (SEC) coupled with native mass spectrometry (nMS) enables the characterization of proteins and protein complexes by combining liquid-phase separation (SEC) and mass measurement (nMS). This approach allows for an increase in the throughput of nMS experiments, reduces the bias that may be present due to the co-ionization of oligomers, and facilitates online sample buffer exchange. Conventional SEC-nMS uses volatile buffers and relatively wide-diameter columns (e.g., ≥1 mm), with flow rates in the tens of μL/min. To ionize sample components under this flow regime, relatively harsh electrospray ionization (ESI) desolvation conditions are needed, potentially resulting in protein dissociation/denaturation. Additionally, relatively large amounts of samples are required (several μgs). Herein, we describe the development of a nanoflow SEC-nMS method using 200 μm I.D. columns, operated at 500 nL min-1. This approach enables buffer exchange, oligomer separation, and mild ionization conditions (e.g., without the assistance of heated gas flow or temperature). Compared to microflow (1 mm I.D. column), the nanoflow method achieved a 4-fold increase in MS peak intensity, despite using a sample 20 times less concentrated (0.05 mg mL-1 for nanoflow vs 1 mg mL-1 for microflow). Furthermore, we evaluated the impact of three injection approaches on sensitivity and separation efficiency: large volume (1 μL), nanovolume (50 nL), and online mixed-bed ion-exchange capillary trap injection. To demonstrate its performance and applicability for sample-limited analysis, the final method using nanovolume injection was applied to several model proteins, protein complexes and a urine sample from a pregnant donor.


16 June 2025 in Analytical Chemistry
Verified
Journal Article
Open access
AZAnnika A. M. van der Zon
Annika A. M. van der Zon
LHLoïs N. Hana
Loïs N. Hana
HHHuda Husein
Huda Husein
THThomas Holmark
Thomas Holmark
ZZZiran Zhai
Ziran Zhai
AGAndrea F.G. Gargano
Andrea F.G. Gargano
Glycosylation significantly impacts the pharmacokinetics and efficacy of monoclonal antibody (mAb) biotherapeutics. Characterizing mAbs' glycoform profiles is crucial for optimizing therapeutic outcomes, and intact antibody analysis provides key information about the glycoform combinations present. While state-of-the-art RPLC-MS methods are commonly used for intact mAb analysis, they lack the selectivity to resolve glycoforms and, therefore, may not detect lower-abundance glycoforms. In contrast, HILIC methods have demonstrated good resolving power for middle-up mAb glycoform analysis. However, to date, no application of HILIC has been described to characterize mAb glycoforms at the intact level. This study describes the development of acrylamide monoliths for HILIC-MS intact mAb glycoprofiling. We studied how the porogen composition (octanol and DMSO ratio) in the polymerization mixture affects the column permeability and separation performance. Our findings indicated that increasing the DMSO content increased retention and decreased the peak widths. The optimized HILIC-MS method was applied to analyze five reference intact mAbs (IgG1 and IgG4). The method demonstrated glycoform selectivity at the intact protein level, achieving baseline separations between single and double Fc glycosylation (e.g., for trastuzumab, resolution (Rs) of 3.62 for G0F vs G0F/G0F) and partial separations between glycoforms differing by one glycan unit (e.g., for trastuzumab, Rs of 1.06 between G0F/G0F and G0F/G1F). Compared to state-of-the-art RPLC-MS, acrylamide-monolith HILIC-MS enabled the measurement of low-abundance glycoforms (e.g., single G0F and M5/M5). The selectivity and sensitivity (ng of sample injection) of this method open opportunities for studies of IgG heterogeneity in bioanalytical applications.

3 November 2024 in ChemRxiv
Verified
Preprint
Open access
PDF file
ACAndrea Cerrato
Andrea Cerrato
THThomas Holmark
Thomas Holmark
EEErik Emke
Erik Emke
EAElvio D. Amato
Elvio D. Amato
AGAndrea F.G. Gargano
Andrea F.G. Gargano
Background: Persistent and mobile organic compounds (PMOC) are of great concern for water quality and human health. The recent improvement and availability of high-resolution mass spectrometry in combination with liquid chromatography have widely expanded the potential of analytical workflows for their detection and quantitation in water. Given their high polarity, the detection of some PMOC requires alternative techniques to reversed-phase chromatography, such as hydrophilic interaction liquid chromatography (HILIC) and supercritical fluid chromatography (SFC). Unified chromatography (UC), an SFC gradient in which the state of the mobile phase changes continuously from supercritical to liquid at 100% polar co-solvent, has shown potential for the analysis of very polar compounds. Results: In the present study, for the first time, a UC-HILIC method coupled with high- resolution mass spectrometry was set up for PMOC analysis in water. SFC and HILIC gradients were run sequentially on the same bare-silica column, with the first separation running to 100% modifier (UC) followed by a HILIC gradient transitioning to water. The UC and UC-HILIC gradients were previously optimized on a mix of 18 representative PMOC to assess solvent and mobile phase composition and for the instrumental system setup. The final method was employed for the analysis of water samples in comparison with a traditional reversed-phase separation, resulting in a significant increase in the number of annotated polar PMOC, including compounds listed in the Candidate List of substances of very high concern for Authorisation by the European Chemicals Agency. Significance: The proposed approach represents a robust alternative to traditional methods for broadening the chemical space of separation and mass spectrometric detection. The introduction of the HILIC section of the gradient was necessary for the elution of strongly retained compounds on the silica phase, thus also reducing the amount of compounds that would be stuck onto the phase of the column, resulting in possible irreproducibility, pressure increase, and loss of efficiency in the compound separation.

28 February 2025 in ChemRxiv
Verified
Preprint
Open access
PDF file
ZZZiran Zhai
Ziran Zhai
THThomas Holmark
Thomas Holmark
AZAnnika A. M. van der Zon
Annika A. M. van der Zon
AGAndrea F.G. Gargano
Andrea F.G. Gargano
Native size-exclusion chromatography (SEC) coupled with native mass spectrometry (nMS) enables the characterization of proteins and protein complexes by combining liquid-phase separation (SEC) and mass measurement of the complexes (nMS). This approach allows for an increase in the throughput of native MS experiments, reduces the bias that may be present due to the co-ionization of oligomers, and facilitates online sample buffer exchange. SEC-nMS uses volatile buffers and relatively wide-diameter columns (e.g., ≥ 1 mm), with flow rates in the tens of µL/minute. To ionize sample components under this flow regime, relatively harsh electrospray ionization (ESI) desolvation conditions are needed, potentially resulting in protein dissociation/denaturation. Also, relatively large amounts of samples are required (several micrograms). Herein, we describe the development of a nanoflow SEC-nMS method using 200 µm I.D. columns, operated at 500 nL min-1. This approach allows buffer exchange, oligomer separation, and mild ionization conditions (e.g., without the assistance of heated gas flow or temperature). Compared to microflow (1 mm I.D. column), the nanoflow method achieved a 4-fold increase in MS peak intensity, despite using a sample 20 times less concentrated (0.05 mg mL-1 for nanoflow vs. 1 mg mL-1 for microflow). Furthermore, we evaluated the impact of three injection approaches on sensitivity and separation efficiency: large-volume (1 μL), nano-volume (50 nL), and online mix-bed ion-exchange capillary trap injection. To demonstrate its performance and applicability for sample-limited analysis, the final method using nano-volume injection was applied to several model proteins, protein complexes, and a urine sample from a pregnant donor.

4 August 2026 in bioRxiv
Verified
Preprint
Open access
PDF file
THThomas Holmark
Thomas Holmark
DMDespoina Mavridou
Despoina Mavridou
ZZZiran Zhai
Ziran Zhai
AZAnnika A.M. van der Zon
Annika A.M. van der Zon
CBConstantin Blöchl
Constantin Blöchl
AGAndrea F.G. Gargano
Andrea F.G. Gargano
Antibody function depends on the molecular pairing of antigen-binding Fab regions with Fc domains, linking antigen specificity to effector potential. However, antibody repertoire methods analyze these subunits separately, creating an inference problem in which Fc-Fab connectivity is lost. Here, we introduce a multi-level HPLC-MS workflow integrating native nanoflow cation-exchange chromatography-MS (nCEC-MS) of intact serum IgG with middle-up Fab and Fc/2 profiling. Native nCEC-MS reduces spectral congestion compared with denaturing reversed-phase HPLC-MS, enabling detection of 56-74 intact IgG mass features from 2 μg of purified IgG per donor. Middle-up analysis provided complementary information on Fab diversity, subclass, and allotype, revealing donor-specific profiles. Reconstructing intact IgG1 masses from independently measured Fab and Fc/2 subunits partially recovers Fc-Fab molecular connectivity and supports interpretation of native intact mass features. Together, this framework provides an integrated view of the human IgG repertoire and establishes a foundation for studying its molecular topology in health and disease.