Xiaomeng Tang

Xiaomeng Tang

Auto-generated profile, based on publicly available information

Xiaomeng Tang

Beijing Key Laboratory of Emerging Infectious Diseases , Institute of Infectious Diseases, Beijing Ditan Hospital, Capital Medical University , Beijing , P.R. China

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 December 2022 in Clinical Chemistry and Laboratory Medicine (CCLM)
Verified
Journal Article
Closed access
MYMinghang Yu
Minghang Yu
DCDanying Chen
Danying Chen
XTXiaomeng Tang
Xiaomeng Tang
YZYuanyuan Zhang
Yuanyuan Zhang
PLPu Liang
Pu Liang
RJRonghua Jin
Ronghua Jin
Objectives: To describe a high-sensitivity SARS-CoV-2 antigen test that is based on the fully automated light-initiated chemiluminescent immunoassay (LiCA®), and to validate its analytical characteristics and clinical agreement on detecting SARS-CoV-2 infection against the reference molecular test. Methods: Analytical performance was validated and detection limits were determined using different types of nucleocapsid protein samples. 798-pair anterior nasal swab specimens were collected from hospitalized patients and asymptomatic screening individuals. Agreement between LiCA® antigen and real-time reverse transcription polymerase chain reaction (rRT-PCR) was evaluated. Results: Repeatability and within-lab precision were 1.6–2.3%. The C5∼C95 interval was −5.1–4.6% away from C50. Detection limits in average (SD) were 325 (±141) U/mL on the national reference panel, 0.07 (±0.04) TCID50/mL on active viral cultures, 0.27 (±0.09) pg/mL on recombinant nucleocapsid proteins and 1.07 (±1.01) TCID50/mL on inactivated viral suspensions, respectively. LiCA detected a median of 374-fold (IQR 137–643) lower levels of the viral antigen than comparative rapid tests. As reference to the rRT-PCR method, overall sensitivity and specificity were determined to be 97.5% (91.4–99.7%) and 99.9% (99.2–100%), respectively. Total agreement between both methods was 99.6% (98.7–99.9%) with Cohen’s kappa 0.98 (0.96–1). A positive detection rate of 100% (95.4–100%) was obtained as Ct≤37.8. Conclusions: The LiCA® system provides an exceptionally high-sensitivity and fully automated platform for the detection of the SARS-CoV-2 antigen in nasal swabs. The assay may have high potential use for large-scale population screening and surveillance of COVID-19 as an alternative to the rRT-PCR test.