Alberto Cabrera

Alberto Cabrera

Auto-generated profile, based on publicly available information

Alberto Cabrera

Universidad de La Laguna, ULL

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 April 2020 in IEEE Transactions on Parallel and Distributed Systems
Verified
Journal Article
Closed access
ACAlberto Cabrera
Alberto Cabrera
AAAlejandro Acosta
Alejandro Acosta
FAFrancisco Almeida
Francisco Almeida
VBVicente Blanco
Vicente Blanco
Modern standards in High Performance Computing (HPC) have started to consider energy consumption and power draw as a limiting factor. New and more complex architectures have been introduced in HPC systems to afford these new restrictions, and include coprocessors such as GPGPUs for intensive computational tasks. As systems increase in heterogeneity, workload distribution becomes a more core problem to achieve the maximum efficiency in every computational component. We present a Multi-Objective Dynamic Load Balancing (DLB) approach where several objectives can be applied to tune an application. These objectives can be dynamically exchanged during the execution of an algorithm to better adapt to the resources available in a system. We have implemented the Multi-Objective DLB together with a generic heuristic engine, designed to perform multiple strategies for DLB in iterative problems. We also present Ull Multiobjective Framework (UllMF), an open-source tool that implements the Multi-Objective generic approach. UllMF separates metric gathering, objective functions to be optimized and load balancing algorithms, and improves code portability using a simple interface to reduce the costs of new implementations. We illustrate how performance and energy consumption are improved for the implemented techniques, and analyze their quality using different DLB techniques from the literature.

5 July 2014 in Computer Science - Research and Development
Verified
Journal Article
Closed access
PDF file
ACAlberto Cabrera
Alberto Cabrera
FAFrancisco Almeida
Francisco Almeida
JAJavier Arteaga
Javier Arteaga
VBVicente Blanco
Vicente Blanco

20 May 2020 in Journal of Scheduling
Verified
Journal Article
Open access
PDF file
TCTomasz Ciesielczyk
Tomasz Ciesielczyk
ACAlberto Cabrera
Alberto Cabrera
AOAriel Oleksiak
Ariel Oleksiak
WPWojciech Piątek
Wojciech Piątek
GWGrzegorz Waligóra
Grzegorz Waligóra
VBVicente Blanco
Vicente Blanco
Rapid growth of demand for remote computational power, along with high energy costs and infrastructure limits, has led to treating power usage as a primary constraint in data centers. Especially, recent challenges related to development of exascale systems or autonomous edge systems require tools that will limit power usage and energy consumption. This paper presents a power capping method that allows operators to quickly adjust the power usage to external conditions and, at the same time, to reduce energy consumption and negative impact on performance of applications. We propose an optimization model and both heuristic and exact methods to solve this problem. We present an evaluation of power capping approaches supported by results of application benchmarks and experiments performed on new heterogeneous servers.

1 February 2013
Verified
Conference Paper
Closed access
ACAlberto Cabrera
Alberto Cabrera
FAFrancisco Almeida
Francisco Almeida
VBVicente Blanco
Vicente Blanco
DGDomingo Giménez
Domingo Giménez
Comparable to time performance models, it is now possible to estimate performance based upon energy consumption for HPC systems. The predictive ability of the analytical modeling is an interesting feature that motivates us to approach this methodology for the case of energy consumption. In this paper, we present an analytical model for predicting the energy consumption for the High Performance Linpack (HPL). The derived model can be used to know in advance the energy consumed by the HPL over a target architecture, and can be integrated into the schedulers of operating systems or queue managers. We established an experimental setup using a standard metered PDU that allowed us to measure the energy consumption for the HPL benchmark on our cluster. With the monitoring system in place, we can obtain the architectural and algorithmic parameters associated for both performance and energy analytical models. Also this has made possible watts and gflops-per-watt prediction when we execute Linpack executions with concrete algorithm parameters in our cluster.

19 December 2018 in The Journal of Supercomputing
Verified
Journal Article
Closed access
PDF file
ACAlberto Cabrera
Alberto Cabrera
AAAlejandro Acosta
Alejandro Acosta
FAFrancisco Almeida
Francisco Almeida
VBVicente Blanco
Vicente Blanco

10 October 2023 in Cluster Computing
Verified
Journal Article
Open access
PDF file
ACAlberto Cabrera
Alberto Cabrera
FAFrancisco Almeida
Francisco Almeida
DCDagoberto Castellanos-Nieves
Dagoberto Castellanos-Nieves
AOAriel Oleksiak
Ariel Oleksiak
VBVicente Blanco
Vicente Blanco
The growing demand for more computing resources has increased the overall energy consumption of computer systems. To support this increasing demand, power and energy consumption must be considered as a constraint on software execution. Modern architectures provide tools for managing the power constraints of a system directly. The Intel Power Cap is a relatively new tool developed to give users fine-grained control over power usage at the central processing unit (CPU) level. The complexity of these tools, in addition to the high variety of modern heterogeneous architectures, hinders predictions of the energy consumption and the performance of any target software. The application of power capping technologies usually leads to the bi-objective optimization problem for energy efficiency and execution time but optimal power constraints could also produce exceeding performance losses. Thus, methods and tools are needed to calculate the proper parameters for power capping technologies, and to optimize energy efficiency. We propose a methodology to analyze the performance and the energy efficiency trade-offs using this power cap technology for a given application. A Pareto front is extracted for the multi-objective performance and energy problem, which represents multiple feasible configurations for both objectives. An extensive experimentation is carried out to categorize the different applications to determine the overall optimal power cap configurations. We propose the use of machine learning (ML) clustering techniques to categorize each application in the target architecture. The use of ML allows us to automate the process and simplifies the effort required to solve the optimization problem. A practical case is presented where we categorize the applications using ML techniques, with the possibility of adding a new application into an existing categorization.