Benjamin D. McElvany

Benjamin D. McElvany

Auto-generated profile, based on publicly available information

Benjamin D. McElvany

Affiliation University of Vermont Medical Center, Burlington, VT, United States of America

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 October 2018 in PLOS Neglected Tropical Diseases
Verified
Journal Article
Open access
PDF file
LKLeah C Katzelnick
Leah C Katzelnick
AEAna Coello Escoto
Ana Coello Escoto
BMBenjamin D McElvany
Benjamin D McElvany
CCChristian Chávez
Christian Chávez
HSHenrik Salje
Henrik Salje
DCDerek A T Cummings
Derek A T Cummings
The gold-standard method for quantifying neutralizing antibody responses to many viruses, including dengue virus (DENV), is the plaque reduction neutralization test (PRNT, also called the immunofocus reduction neutralization test). The PRNT conducted on 96-well plates is high-throughput and requires a smaller volume of antiserum than on 6- or 24-well plates, but manual plaque counting is challenging and existing automated plaque counters are expensive or difficult to optimize. We have developed Viridot (Viridot package), a program for R with a user interface in shiny, that counts viral plaques of a variety of phenotypes, estimates neutralizing antibody titers, and performs other calculations of use to virologists. The Viridot plaque counter includes an automatic parameter identification mode (misses <10 plaques/well for 87% of diverse DENV strains [n = 1521]) and a mode that allows the user to fine-tune the parameters used for counting plaques. We compared standardized manual and Viridot plaque counting methods applied to the same wells by two analyses and found that Viridot plaque counts were as similar to the same analyst's manual count (Lin’s concordance correlation coefficient, ρc = 0.99 [95% confidence interval: 0.99–1.00]) as manual counts between analysts (ρc = 0.99 [95% CI: 0.98–0.99]). The average ratio of neutralizing antibody titers based on manual counted plaques to Viridot counted plaques was 1.05 (95% CI: 0.98–1.14), similar to the average ratio of antibody titers based on manual plaque counts by the two analysts (1.06 [95% CI: 0.84–1.34]). Across diverse DENV and ZIKV strains (n = 14), manual and Viridot plaque counts were mostly consistent (range of ρc = 0.74 to 1.00) and the average ratio of antibody titers based on manual and Viridot counted plaques was close to 1 (0.94 [0.86–1.02]). Thus, Viridot can be used for plaque counting and neutralizing antibody titer estimation of diverse DENV strains and potentially other viruses on 96-well plates as well as for formalization of plaque-counting rules for standardization across experiments and analysts. Although the plaque reduction neutralization test (PRNT) is an important assay for measuring neutralizing antibody responses against many viruses, no free, open-source programs specifically designed for virus plaque counting and neutralizing antibody titer estimation are available. We have developed Viridot, a package for R with a user-interface in shiny, which is designed for use by laboratory-based virologists and researchers with minimal coding experience. The program includes: automatic and user-specification of settings for plaque counting; saving of plaque counting settings; counting of many plates at once; and easy output of plaque counts, plaque sizes, and images with counted plaques circled. Viridot also includes programs to analyze plaque counts, including estimation of: neutralizing antibody titers, pfu/mL of a virus stock, and the dilution factor of virus needed for an experiment. Viridot can be used to standardize plaque-counting methods within and between laboratories, helping researchers formalize an important aspect of the PRNT method that is often subjective. Viridot thus provides laboratory researchers around the world with a free tool to improve the speed and consistency with which the PRNT is conducted, aiding the public health response to emerging viral diseases.

26 July 2021 in PLOS ONE
Verified
Journal Article
Open access
PDF file
DWDavis T. Weaver
Davis T. Weaver
BMBenjamin D. McElvany
Benjamin D. McElvany
VGVishhvaan Gopalakrishnan
Vishhvaan Gopalakrishnan
KCKyle Joseph Card
Kyle Joseph Card
DCDena Crozier
Dena Crozier
JSJacob G Scott
Jacob G Scott
Personal protective equipment (PPE) is crucially important to the safety of both patients and medical personnel, particularly in the event of an infectious pandemic. As the incidence of Coronavirus Disease 2019 (COVID-19) increases exponentially in the United States and many parts of the world, healthcare provider demand for these necessities is currently outpacing supply. In the midst of the current pandemic, there has been a concerted effort to identify viable ways to conserve PPE, including decontamination after use. In this study, we outline a procedure by which PPE may be decontaminated using ultraviolet (UV) radiation in biosafety cabinets (BSCs), a common element of many academic, public health, and hospital laboratories. According to the literature, effective decontamination of N95 respirator masks or surgical masks requires UV-C doses of greater than 1 Jcm−2, which was achieved after 4.3 hours per side when placing the N95 at the bottom of the BSCs tested in this study. We then demonstrated complete inactivation of the human coronavirus NL63 on N95 mask material after 15 minutes of UV-C exposure at 61 cm (232 μWcm−2). Our results provide support to healthcare organizations looking for methods to extend their reserves of PPE.